Literature DB >> 28233760

Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

A Uneri1, T De Silva, J Goerres, M W Jacobson, M D Ketcha, S Reaungamornrat, G Kleinszig, S Vogt, A J Khanna, G M Osgood, J-P Wolinsky, J H Siewerdsen.   

Abstract

Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registration method wherein intraoperative radiographs are leveraged in combination with prior knowledge of the patient and surgical components for quantitative assessment of device placement and more rigorous quality assurance (QA) of the surgical product. The algorithm is based on known-component registration (KC-Reg) in which patient-specific preoperative CT and parametric component models are used. The registration performs optimization of gradient similarity, removes the need for offline geometric calibration of the C-arm, and simultaneously solves for multiple component bodies, thereby allowing QA in a single step (e.g. spinal construct with 4-20 screws). Performance was tested in a spine phantom, and first clinical results are reported for QA of transpedicle screws delivered in a patient undergoing thoracolumbar spine surgery. Simultaneous registration of ten pedicle screws (five contralateral pairs) demonstrated mean target registration error (TRE) of 1.1  ±  0.1 mm at the screw tip and 0.7  ±  0.4° in angulation when a prior geometric calibration was used. The calibration-free formulation, with the aid of component collision constraints, achieved TRE of 1.4  ±  0.6 mm. In all cases, a statistically significant improvement (p  <  0.05) was observed for the simultaneous solutions in comparison to previously reported sequential solution of individual components. Initial application in clinical data in spine surgery demonstrated TRE of 2.7  ±  2.6 mm and 1.5  ±  0.8°. The KC-Reg algorithm offers an independent check and quantitative QA of the surgical product using radiographic/fluoroscopic views acquired within standard OR workflow. Such intraoperative assessment could improve quality and safety, provide the opportunity to revise suboptimal constructs in the OR, and reduce the frequency of revision surgery.

Entities:  

Mesh:

Year:  2017        PMID: 28233760      PMCID: PMC5901722          DOI: 10.1088/1361-6560/aa62c5

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  29 in total

Review 1.  Completely derandomized self-adaptation in evolution strategies.

Authors:  N Hansen; A Ostermeier
Journal:  Evol Comput       Date:  2001       Impact factor: 3.277

Review 2.  Image-guided surgery: what is the accuracy?

Authors:  Robert F Labadie; Bryan M Davis; J Michael Fitzpatrick
Journal:  Curr Opin Otolaryngol Head Neck Surg       Date:  2005-02       Impact factor: 2.064

3.  Intraoperative cone beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation.

Authors:  Ehsan Tabaraee; Anthony G Gibson; Dean G Karahalios; Eric A Potts; Jean-Pierre Mobasser; Shane Burch
Journal:  Spine (Phila Pa 1976)       Date:  2013-10-15       Impact factor: 3.468

4.  Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance.

Authors:  A Uneri; A S Wang; Y Otake; G Kleinszig; S Vogt; A J Khanna; G L Gallia; Z L Gokaslan; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

5.  3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.

Authors:  A Uneri; Y Otake; A S Wang; G Kleinszig; S Vogt; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

6.  Cervical spine fusion in rheumatoid arthritis.

Authors:  C S Ranawat; P O'Leary; P Pellicci; P Tsairis; P Marchisello; L Dorr
Journal:  J Bone Joint Surg Am       Date:  1979-10       Impact factor: 5.284

7.  Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period.

Authors:  Ronald A Lehman; Lawrence G Lenke; Kathryn A Keeler; Yongjung J Kim; Gene Cheh
Journal:  Spine (Phila Pa 1976)       Date:  2007-11-15       Impact factor: 3.468

8.  3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch.

Authors:  T De Silva; A Uneri; M D Ketcha; S Reaungamornrat; G Kleinszig; S Vogt; N Aygun; S-F Lo; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-18       Impact factor: 3.609

9.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery.

Authors:  Y Otake; S Schafer; J W Stayman; W Zbijewski; G Kleinszig; R Graumann; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-08-03       Impact factor: 3.609

10.  Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement?

Authors:  Jonathan N Sembrano; David W Polly; Charles Gerald T Ledonio; Edward Rainier G Santos
Journal:  Int J Spine Surg       Date:  2012-12-01
View more
  21 in total

1.  Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Joseph Goerres; Matthew W Jacobson; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2017-07-11       Impact factor: 10.048

2.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

3.  Robotic drill guide positioning using known-component 3D-2D image registration.

Authors:  Thomas Yi; Vignesh Ramchandran; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06

4.  Known-component metal artifact reduction (KC-MAR) for cone-beam CT.

Authors:  A Uneri; X Zhang; T Yi; J W Stayman; P A Helm; G M Osgood; N Theodore; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2019-08-21       Impact factor: 3.609

5.  Data-Driven Deformable 3D-2D Registration for Guiding Neuroelectrode Placement in Deep Brain Stimulation.

Authors:  A Uneri; P Wu; C K Jones; M D Ketcha; P Vagdargi; R Han; P A Helm; M Luciano; W S Anderson; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-23

6.  Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration.

Authors:  J Goerres; A Uneri; M Jacobson; B Ramsay; T De Silva; M Ketcha; R Han; A Manbachi; S Vogt; G Kleinszig; J-P Wolinsky; G Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

7.  An intraoperative fluoroscopic method to accurately measure the post-implantation position of pedicle screws.

Authors:  Robyn Newell; Hooman Esfandiari; Carolyn Anglin; Renee Bernard; John Street; Antony J Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-04-09       Impact factor: 2.924

8.  A deep learning framework for segmentation and pose estimation of pedicle screw implants based on C-arm fluoroscopy.

Authors:  Hooman Esfandiari; Robyn Newell; Carolyn Anglin; John Street; Antony J Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-28       Impact factor: 2.924

9.  3D-2D Image Registration in Virtual Long-Film Imaging: Application to Spinal Deformity Correction.

Authors:  A Uneri; X Zhang; J W Stayman; P A Helm; G M Osgood; N Theodore; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

10.  Quantitative Assessment of Weight-Bearing Fracture Biomechanics Using Extremity Cone-Beam CT.

Authors:  S Z Liu; Q Cao; G M Osgood; J H Siewerdsen; J W Stayman; W Zbijewski
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-02
View more