Literature DB >> 24351769

3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.

A Uneri1, Y Otake, A S Wang, G Kleinszig, S Vogt, A J Khanna, J H Siewerdsen.   

Abstract

An algorithm for intensity-based 3D-2D registration of CT and x-ray projections is evaluated, specifically using single- or dual-projection views to provide 3D localization. The registration framework employs the gradient information similarity metric and covariance matrix adaptation evolution strategy to solve for the patient pose in six degrees of freedom. Registration performance was evaluated in an anthropomorphic phantom and cadaver, using C-arm projection views acquired at angular separation, Δθ, ranging from ∼0°-180° at variable C-arm magnification. Registration accuracy was assessed in terms of 2D projection distance error and 3D target registration error (TRE) and compared to that of an electromagnetic (EM) tracker. The results indicate that angular separation as small as Δθ ∼10°-20° achieved TRE <2 mm with 95% confidence, comparable or superior to that of the EM tracker. The method allows direct registration of preoperative CT and planning data to intraoperative fluoroscopy, providing 3D localization free from conventional limitations associated with external fiducial markers, stereotactic frames, trackers and manual registration.

Entities:  

Mesh:

Year:  2013        PMID: 24351769      PMCID: PMC4927006          DOI: 10.1088/0031-9155/59/2/271

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  Stereotactic navigation for placement of pedicle screws in the thoracic spine.

Authors:  A S Youkilis; D J Quint; J E McGillicuddy; S M Papadopoulos
Journal:  Neurosurgery       Date:  2001-04       Impact factor: 4.654

2.  Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery.

Authors:  R M Comeau; A F Sadikot; A Fenster; T M Peters
Journal:  Med Phys       Date:  2000-04       Impact factor: 4.071

3.  Registration in interventional procedures with optical navigator.

Authors:  E Vahala; M Ylihautala; J Tuominen; H Schiffbauer; J Katisko; S Yrjänä; T Vaara; G Ehnholm; J Koivukangas
Journal:  J Magn Reson Imaging       Date:  2001-01       Impact factor: 4.813

4.  3D/2D model-to-image registration applied to TIPS surgery.

Authors:  Julien Jomier; Elizabeth Bullitt; Mark Van Horn; Chetna Pathak; Stephen R Aylward
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

5.  C-arm tracking and reconstruction without an external tracker.

Authors:  Ameet Jain; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

6.  Computer-assisted surgery for dynamic hip screw, using Surgix, a novel intraoperative guiding system.

Authors:  Amir Herman; Assaf Dekel; Itamar B Botser; Ely L Steinberg
Journal:  Int J Med Robot       Date:  2009-03       Impact factor: 2.547

7.  Dynamic Active Contours for Visual Tracking.

Authors:  Marc Niethammer; Allen Tannenbaum; Sigurd Angenent
Journal:  IEEE Trans Automat Contr       Date:  2006       Impact factor: 5.792

8.  Binocular distance perception.

Authors:  J M Foley
Journal:  Psychol Rev       Date:  1980-09       Impact factor: 8.934

9.  A new registration/visualization paradigm for CT-fluoroscopy guided RF liver ablation.

Authors:  Ruxandra Micu; Tobias F Jakobs; Martin Urschler; Nassir Navab
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

10.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery.

Authors:  Y Otake; S Schafer; J W Stayman; W Zbijewski; G Kleinszig; R Graumann; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-08-03       Impact factor: 3.609

View more
  22 in total

1.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

2.  Task-driven source-detector trajectories in cone-beam computed tomography: II. Application to neuroradiology.

Authors:  Sarah Capostagno; J Webster Stayman; Matthew Jacobson; Tina Ehtiati; Clifford R Weiss; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-09

3.  Fusion Image Guidance for Supra-Aortic Vessel Catheterization in Neurointerventions: A Feasibility Study.

Authors:  A Feddal; S Escalard; F Delvoye; R Fahed; J P Desilles; K Zuber; H Redjem; J S Savatovsky; G Ciccio; S Smajda; M Ben Maacha; M Mazighi; M Piotin; R Blanc
Journal:  AJNR Am J Neuroradiol       Date:  2020-08-20       Impact factor: 3.825

4.  Robotic drill guide positioning using known-component 3D-2D image registration.

Authors:  Thomas Yi; Vignesh Ramchandran; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06

5.  Known-component 3D-2D registration for quality assurance of spine surgery pedicle screw placement.

Authors:  A Uneri; T De Silva; J W Stayman; G Kleinszig; S Vogt; A J Khanna; Z L Gokaslan; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-09-30       Impact factor: 3.609

6.  Pose-aware C-arm for automatic re-initialization of interventional 2D/3D image registration.

Authors:  Javad Fotouhi; Bernhard Fuerst; Alex Johnson; Sing Chun Lee; Russell Taylor; Greg Osgood; Nassir Navab; Mehran Armand
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-19       Impact factor: 2.924

7.  Self-calibration of cone-beam CT geometry using 3D-2D image registration.

Authors:  S Ouadah; J W Stayman; G J Gang; T Ehtiati; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-10       Impact factor: 3.609

8.  Known-Component 3D-2D Registration for Image Guidance and Quality Assurance in Spine Surgery Pedicle Screw Placement.

Authors:  A Uneri; J W Stayman; T De Silva; A S Wang; G Kleinszig; S Vogt; A J Khanna; J-P Wolinsky; Z L Gokaslan; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

9.  Correction of patient motion in cone-beam CT using 3D-2D registration.

Authors:  S Ouadah; M Jacobson; J W Stayman; T Ehtiati; C Weiss; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-09       Impact factor: 3.609

10.  Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration.

Authors:  J Goerres; A Uneri; M Jacobson; B Ramsay; T De Silva; M Ketcha; R Han; A Manbachi; S Vogt; G Kleinszig; J-P Wolinsky; G Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.