Literature DB >> 31287092

Known-component metal artifact reduction (KC-MAR) for cone-beam CT.

A Uneri1, X Zhang, T Yi, J W Stayman, P A Helm, G M Osgood, N Theodore, J H Siewerdsen.   

Abstract

Intraoperative cone-beam CT (CBCT) is increasingly used for surgical navigation and validation of device placement. In spinal deformity correction, CBCT provides visualization of pedicle screws and fixation rods in relation to adjacent anatomy. This work reports and evaluates a method that uses prior information regarding such surgical instrumentation for improved metal artifact reduction (MAR). The known-component MAR (KC-MAR) approach achieves precise localization of instrumentation in projection images using rigid or deformable 3D-2D registration of component models, thereby overcoming residual errors associated with segmentation-based methods. Projection data containing metal components are processed via 2D inpainting of the detector signal, followed by 3D filtered back-projection (FBP). Phantom studies were performed to identify nominal algorithm parameters and quantitatively investigate performance over a range of component material composition and size. A cadaver study emulating screw and rod placement in spinal deformity correction was conducted to evaluate performance under realistic clinical imaging conditions. KC-MAR demonstrated reduction in artifacts (standard deviation in voxel values) across a range of component types and dose levels, reducing the artifact to 5-10 HU. Accurate component delineation was demonstrated for rigid (screw) and deformable (rod) models with sub-mm registration errors, and a single-pixel dilation of the projected components was found to compensate for partial-volume effects. Artifacts associated with spine screws and rods were reduced by 40%-80% in cadaver studies, and the resulting images demonstrated markedly improved visualization of instrumentation (e.g. screw threads) within cortical margins. The KC-MAR algorithm combines knowledge of surgical instrumentation with 3D image reconstruction in a manner that overcomes potential pitfalls of segmentation. The approach is compatible with FBP-thereby maintaining simplicity in a manner that is consistent with surgical workflow-or more sophisticated model-based reconstruction methods that could further improve image quality and/or help reduce radiation dose.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31287092      PMCID: PMC7262472          DOI: 10.1088/1361-6560/ab3036

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  36 in total

1.  An iterative maximum-likelihood polychromatic algorithm for CT.

Authors:  B De Man; J Nuyts; P Dupont; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  2001-10       Impact factor: 10.048

2.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies.

Authors:  Mehran Yazdi; Mehran Yazdia; Luc Gingras; Luc Beaulieu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

3.  A segmentation-based method for metal artifact reduction.

Authors:  Hengyong Yu; Kai Zeng; Deepak K Bharkhada; Ge Wang; Mark T Madsen; Osama Saba; Bruno Policeni; Matthew A Howard; Wendy R K Smoker
Journal:  Acad Radiol       Date:  2007-04       Impact factor: 3.173

4.  A comparison of similarity measures for use in 2-D-3-D medical image registration.

Authors:  G P Penney; J Weese; J A Little; P Desmedt; D L Hill; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1998-08       Impact factor: 10.048

5.  Beam hardening in x-ray reconstructive tomography.

Authors:  R A Brooks; G Di Chiro
Journal:  Phys Med Biol       Date:  1976-05       Impact factor: 3.609

6.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

7.  A pattern recognition method for the removal of streaking artifact in computed tomography.

Authors:  R L Morin; D E Raeside
Journal:  Radiology       Date:  1981-10       Impact factor: 11.105

8.  Metal Artifact Reduction in X-ray Computed Tomography Using Computer-Aided Design Data of Implants as Prior Information.

Authors:  Veikko Ruth; Daniel Kolditz; Christian Steiding; Willi A Kalender
Journal:  Invest Radiol       Date:  2017-06       Impact factor: 6.016

9.  Polyenergetic known-component CT reconstruction with unknown material compositions and unknown x-ray spectra.

Authors:  S Xu; A Uneri; A Jay Khanna; J H Siewerdsen; J W Stayman
Journal:  Phys Med Biol       Date:  2017-02-23       Impact factor: 3.609

10.  Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

Authors:  A Uneri; T De Silva; J Goerres; M W Jacobson; M D Ketcha; S Reaungamornrat; G Kleinszig; S Vogt; A J Khanna; G M Osgood; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-02-24       Impact factor: 3.609

View more
  8 in total

1.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

2.  Data-Driven Detection and Registration of Spine Surgery Instrumentation in Intraoperative Images.

Authors:  S A Doerr; A Uneri; Y Huang; C K Jones; X Zhang; M D Ketcha; P A Helm; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-16

3.  Accuracy Assessment of Percutaneous Pedicle Screw Placement Using Cone Beam Computed Tomography with Metal Artifact Reduction.

Authors:  Yann Philippe Charles; Rawan Al Ansari; Arnaud Collinet; Pierre De Marini; Jean Schwartz; Rami Nachabe; Dirk Schäfer; Bernhard Brendel; Afshin Gangi; Roberto Luigi Cazzato
Journal:  Sensors (Basel)       Date:  2022-06-18       Impact factor: 3.847

4.  Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms.

Authors:  P Wu; A Sisniega; J W Stayman; W Zbijewski; D Foos; X Wang; N Khanna; N Aygun; R D Stevens; J H Siewerdsen
Journal:  Med Phys       Date:  2020-04-03       Impact factor: 4.071

5.  Sinogram + image domain neural network approach for metal artifact reduction in low-dose cone-beam computed tomography.

Authors:  Michael D Ketcha; Michael Marrama; Andre Souza; Ali Uneri; Pengwei Wu; Xiaoxuan Zhang; Patrick A Helm; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2021-03-13

6.  Model-based dual-energy tomographic image reconstruction of objects containing known metal components.

Authors:  Stephen Z Liu; Qian Cao; Matthew Tivnan; Steven Tilley Ii; Jeffrey H Siewerdsen; J Webster Stayman; Wojciech Zbijewski
Journal:  Phys Med Biol       Date:  2020-12-22       Impact factor: 4.174

7.  C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT.

Authors:  P Wu; N Sheth; A Sisniega; A Uneri; R Han; R Vijayan; P Vagdargi; B Kreher; H Kunze; G Kleinszig; S Vogt; S F Lo; N Theodore; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2020-08-19       Impact factor: 4.174

8.  Combining dual-tree complex wavelets and multiresolution in iterative CT reconstruction with application to metal artifact reduction.

Authors:  Defne Us; Ulla Ruotsalainen; Sampsa Pursiainen
Journal:  Biomed Eng Online       Date:  2019-12-05       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.