Literature DB >> 29430481

Robotic drill guide positioning using known-component 3D-2D image registration.

Thomas Yi1, Vignesh Ramchandran1, Jeffrey H Siewerdsen1, Ali Uneri1.   

Abstract

A method for x-ray image-guided robotic instrument positioning is reported and evaluated in preclinical studies of spinal pedicle screw placement with the aim of improving delivery of transpedicle K-wires and screws. The known-component (KC) registration algorithm was used to register the three-dimensional patient CT and drill guide surface model to intraoperative two-dimensional radiographs. Resulting transformations, combined with offline hand-eye calibration, drive the robotically held drill guide to target trajectories defined in the preoperative CT. The method was assessed in comparison with a more conventional tracker-based approach, and robustness to clinically realistic errors was tested in phantom and cadaver. Deviations from planned trajectories were analyzed in terms of target registration error (TRE) at the tooltip (mm) and approach angle (deg). In phantom studies, the KC approach resulted in [Formula: see text] and [Formula: see text], comparable with accuracy in tracker-based approach. In cadaver studies with realistic anatomical deformation, the KC approach yielded [Formula: see text] and [Formula: see text], with statistically significant improvement versus tracker ([Formula: see text] and [Formula: see text]). Robustness to deformation is attributed to relatively local rigidity of anatomy in radiographic views. X-ray guidance offered accurate robotic positioning and could fit naturally within clinical workflow of fluoroscopically guided procedures.

Entities:  

Keywords:  3D–2D registration; image-guided surgery; known-component registration; surgical robotics

Year:  2018        PMID: 29430481      PMCID: PMC5800483          DOI: 10.1117/1.JMI.5.2.021212

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  23 in total

1.  Lumbar pedicle: surgical anatomic evaluation and relationships.

Authors:  A Attar; H C Ugur; A Uz; I Tekdemir; N Egemen; Y Genc
Journal:  Eur Spine J       Date:  2001-02       Impact factor: 3.134

Review 2.  Completely derandomized self-adaptation in evolution strategies.

Authors:  N Hansen; A Ostermeier
Journal:  Evol Comput       Date:  2001       Impact factor: 3.277

3.  Optimal surgical planning guidance for lumbar spinal fusion considering operational safety and vertebra-screw interface strength.

Authors:  Jongwon Lee; Sungmin Kim; Young Soo Kim; Wan Kyun Chung
Journal:  Int J Med Robot       Date:  2012-02-23       Impact factor: 2.547

4.  Pedicle screw placement accuracy: a meta-analysis.

Authors:  Victor Kosmopoulos; Constantin Schizas
Journal:  Spine (Phila Pa 1976)       Date:  2007-02-01       Impact factor: 3.468

5.  Innovative approach in the development of computer assisted algorithm for spine pedicle screw placement.

Authors:  Giovanni F Solitro; Farid Amirouche
Journal:  Med Eng Phys       Date:  2016-02-24       Impact factor: 2.242

6.  3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.

Authors:  A Uneri; Y Otake; A S Wang; G Kleinszig; S Vogt; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

Review 7.  Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws.

Authors:  Oliver P Gautschi; Bawarjan Schatlo; Karl Schaller; Enrico Tessitore
Journal:  Neurosurg Focus       Date:  2011-10       Impact factor: 4.047

8.  3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch.

Authors:  T De Silva; A Uneri; M D Ketcha; S Reaungamornrat; G Kleinszig; S Vogt; N Aygun; S-F Lo; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-18       Impact factor: 3.609

9.  Spinal pedicle screw planning using deformable atlas registration.

Authors:  J Goerres; A Uneri; T De Silva; M Ketcha; S Reaungamornrat; M Jacobson; S Vogt; G Kleinszig; G Osgood; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-02-08       Impact factor: 4.174

10.  Technical accuracy of optical and the electromagnetic tracking systems.

Authors:  Tapani Koivukangas; Jani Pa Katisko; John P Koivukangas
Journal:  Springerplus       Date:  2013-03-08
View more
  8 in total

1.  Fiducial-Free 2D/3D Registration for Robot-Assisted Femoroplasty.

Authors:  Cong Gao; Amirhossein Farvardin; Robert B Grupp; Mahsan Bakhtiarinejad; Liuhong Ma; Mareike Thies; Mathias Unberath; Russell H Taylor; Mehran Armand
Journal:  IEEE Trans Med Robot Bionics       Date:  2020-07-28

2.  Technical Note: Known-Component Registration for Robotic Drill Guide Positioning.

Authors:  T Yi; V Ramchandran; J H Siewerdsen; A Uneri
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-13

3.  Fluoroscopic Guidance of a Surgical Robot: Pre-clinical Evaluation in Pelvic Guidewire Placement.

Authors:  R C Vijayan; R Han; P Wu; N M Sheth; P Vagdargi; S Vogt; G Kleinszig; G M Osgood; J H Siewerdsen; A Uneri
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-25

4.  Image-Guided Robotic K-Wire Placement for Orthopaedic Trauma Surgery.

Authors:  R C Vijayan; R Han; P Wu; N M Sheth; M D Ketcha; P Vagdargi; S Vogt; G Kleinszig; G M Osgood; J H Siewerdsen; A Uneri
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-16

5.  Pose Estimation of Periacetabular Osteotomy Fragments With Intraoperative X-Ray Navigation.

Authors:  Robert B Grupp; Rachel A Hegeman; Ryan J Murphy; Clayton P Alexander; Yoshito Otake; Benjamin A McArthur; Mehran Armand; Russell H Taylor
Journal:  IEEE Trans Biomed Eng       Date:  2019-05-06       Impact factor: 4.538

6.  A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

Authors:  N M Sheth; T De Silva; A Uneri; M Ketcha; R Han; R Vijayan; G M Osgood; J H Siewerdsen
Journal:  Med Phys       Date:  2020-01-06       Impact factor: 4.506

7.  Development of a fluoroscopically guided robotic assistant for instrument placement in pelvic trauma surgery.

Authors:  Rohan C Vijayan; Runze Han; Pengwei Wu; Niral M Sheth; Michael D Ketcha; Prasad Vagdargi; Sebastian Vogt; Gerhard Kleinszig; Greg M Osgood; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2021-06-09

8.  Development and Pre-Clinical Analysis of Spatiotemporal-Aware Augmented Reality in Orthopedic Interventions.

Authors:  Javad Fotouhi; Arian Mehrfard; Tianyu Song; Alex Johnson; Greg Osgood; Mathias Unberath; Mehran Armand; Nassir Navab
Journal:  IEEE Trans Med Imaging       Date:  2021-02-02       Impact factor: 10.048

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.