3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch.

T De Silva1, A Uneri, M D Ketcha, S Reaungamornrat, G Kleinszig, S Vogt, N Aygun, S-F Lo, J-P Wolinsky, J H Siewerdsen.   

Abstract

In image-guided spine surgery, robust three-dimensional to two-dimensional (3D-2D) registration of preoperative computed tomography (CT) and intraoperative radiographs can be challenged by the image content mismatch associated with the presence of surgical instrumentation and implants as well as soft-tissue resection or deformation. This work investigates image similarity metrics in 3D-2D registration offering improved robustness against mismatch, thereby improving performance and reducing or eliminating the need for manual masking. The performance of four gradient-based image similarity metrics (gradient information (GI), gradient correlation (GC), gradient information with linear scaling (GS), and gradient orientation (GO)) with a multi-start optimization strategy was evaluated in an institutional review board-approved retrospective clinical study using 51 preoperative CT images and 115 intraoperative mobile radiographs. Registrations were tested with and without polygonal masks as a function of the number of multistarts employed during optimization. Registration accuracy was evaluated in terms of the projection distance error (PDE) and assessment of failure modes (PDE  >  30 mm) that could impede reliable vertebral level localization. With manual polygonal masking and 200 multistarts, the GC and GO metrics exhibited robust performance with 0% gross failures and median PDE < 6.4 mm (±4.4 mm interquartile range (IQR)) and a median runtime of 84 s (plus upwards of 1-2 min for manual masking). Excluding manual polygonal masks and decreasing the number of multistarts to 50 caused the GC-based registration to fail at a rate of >14%; however, GO maintained robustness with a 0% gross failure rate. Overall, the GI, GC, and GS metrics were susceptible to registration errors associated with content mismatch, but GO provided robust registration (median PDE  =  5.5 mm, 2.6 mm IQR) without manual masking and with an improved runtime (29.3 s). The GO metric improved the registration accuracy and robustness in the presence of strong image content mismatch. This capability could offer valuable assistance and decision support in spine level localization in a manner consistent with clinical workflow.

Entities:  

Mesh:

Year:  2016        PMID: 26992245      PMCID: PMC4915376          DOI: 10.1088/0031-9155/61/8/3009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy.

Authors:  Ali Khamene; Peter Bloch; Wolfgang Wein; Michelle Svatos; Frank Sauer
Journal:  Med Image Anal       Date:  2005-09-08       Impact factor: 8.545

2.  A protocol for evaluation of similarity measures for rigid registration.

Authors:  Darko Skerl; Bostjan Likar; Franjo Pernus
Journal:  IEEE Trans Med Imaging       Date:  2006-06       Impact factor: 10.048

3.  Automated model-based vertebra detection, identification, and segmentation in CT images.

Authors:  Tobias Klinder; Jörn Ostermann; Matthias Ehm; Astrid Franz; Reinhard Kneser; Cristian Lorenz
Journal:  Med Image Anal       Date:  2009-02-20       Impact factor: 8.545

4.  Automatic localization of target vertebrae in spine surgery: clinical evaluation of the LevelCheck registration algorithm.

Authors:  Sheng-Fu L Lo; Yoshito Otake; Varun Puvanesarajah; Adam S Wang; Ali Uneri; Tharindu De Silva; Sebastian Vogt; Gerhard Kleinszig; Benjamin D Elder; C Rory Goodwin; Thomas A Kosztowski; Jason A Liauw; Mari Groves; Ali Bydon; Daniel M Sciubba; Timothy F Witham; Jean-Paul Wolinsky; Nafi Aygun; Ziya L Gokaslan; Jeffrey H Siewerdsen
Journal:  Spine (Phila Pa 1976)       Date:  2015-04-15       Impact factor: 3.468

5.  Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy.

Authors:  Jian Wu; Minho Kim; Jorg Peters; Heeteak Chung; Sanjiv S Samant
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

6.  A comparison of similarity measures for use in 2-D-3-D medical image registration.

Authors:  G P Penney; J Weese; J A Little; P Desmedt; D L Hill; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1998-08       Impact factor: 10.048

7.  Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach.

Authors:  Sajendra Nithiananthan; Sebastian Schafer; Ali Uneri; Daniel J Mirota; J Webster Stayman; Wojciech Zbijewski; Kristy K Brock; Michael J Daly; Harley Chan; Jonathan C Irish; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

8.  Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: initial investigation of a combined model- and image-driven approach.

Authors:  Ali Uneri; Sajendra Nithiananthan; Sebastian Schafer; Yoshito Otake; J Webster Stayman; Gerhard Kleinszig; Marc S Sussman; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

9.  Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Authors:  Christelle Gendrin; Primoz Markelj; Supriyanto Ardjo Pawiro; Jakob Spoerk; Christoph Bloch; Christoph Weber; Michael Figl; Helmar Bergmann; Wolfgang Birkfellner; Bostjan Likar; Franjo Pernus
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

10.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery.

Authors:  Y Otake; S Schafer; J W Stayman; W Zbijewski; G Kleinszig; R Graumann; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-08-03       Impact factor: 3.609

View more
  33 in total

1.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

2.  A comparative analysis of intensity-based 2D-3D registration for intraoperative use in pedicle screw insertion surgeries.

Authors:  Hooman Esfandiari; Carolyn Anglin; Pierre Guy; John Street; Simon Weidert; Antony J Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-10       Impact factor: 2.924

3.  Deep-learning based multi-modal retinal image registration for the longitudinal analysis of patients with age-related macular degeneration.

Authors:  Tharindu De Silva; Emily Y Chew; Nathan Hotaling; Catherine A Cukras
Journal:  Biomed Opt Express       Date:  2020-12-23       Impact factor: 3.732

4.  Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery.

Authors:  M D Ketcha; T De Silva; A Uneri; G Kleinszig; S Vogt; J-P Wolinsky; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18

5.  Robotic drill guide positioning using known-component 3D-2D image registration.

Authors:  Thomas Yi; Vignesh Ramchandran; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06

6.  Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction.

Authors:  Tharindu De Silva; Joshua Punnoose; Ali Uneri; Mahadevappa Mahesh; Joseph Goerres; Matthew Jacobson; Michael D Ketcha; Amir Manbachi; Sebastian Vogt; Gerhard Kleinszig; Akhil Jay Khanna; Jean-Paul Wolinksy; Jeffrey H Siewerdsen; Greg Osgood
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-13

7.  Co-localized augmented human and X-ray observers in collaborative surgical ecosystem.

Authors:  Javad Fotouhi; Mathias Unberath; Tianyu Song; Jonas Hajek; Sing Chun Lee; Bastian Bier; Andreas Maier; Greg Osgood; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-26       Impact factor: 2.924

8.  Multi-stage 3D-2D registration for correction of anatomical deformation in image-guided spine surgery.

Authors:  M D Ketcha; T De Silva; A Uneri; M W Jacobson; J Goerres; G Kleinszig; S Vogt; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-04-04       Impact factor: 3.609

9.  A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

Authors:  Yujie Chi; Chenyang Shen; Bin Li; You Zhang; Ming Yang; Michael Folkert; Xun Jia
Journal:  Phys Med Biol       Date:  2019-11-21       Impact factor: 3.609

10.  Correction of patient motion in cone-beam CT using 3D-2D registration.

Authors:  S Ouadah; M Jacobson; J W Stayman; T Ehtiati; C Weiss; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-09       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.