Literature DB >> 28138947

Energy-sensitive photon counting detector-based X-ray computed tomography.

Katsuyuki Taguchi1.   

Abstract

Energy-sensitive photon counting detectors (PCDs) have recently been developed for medical X-ray computed tomography (CT) imaging and a handful of prototype PCD-CT systems have been built and evaluated. PCDs detect X-rays by using mechanisms that are completely different from the current CT detectors (i.e., energy integrating detectors or EIDs); PCDs count photons and obtain the information of the object tissues (i.e., the effective atomic numbers and mass densities) to be imaged. Therefore, these PCDs have the potential not only for evolution-to improve the current CT images such as providing dose reduction-but also for a revolution-to enable novel applications with a new concept such as molecular CT imaging. The performance of PCDs, however, is not flawless, and thus, it requires integrated efforts to develop PCD-CT for clinical use. In this article, we review the current status and the prediction for the future of PCDs, PCD-CT systems, and potential clinical applications.

Entities:  

Keywords:  Computed tomography; Photon counting; X-ray

Mesh:

Year:  2017        PMID: 28138947     DOI: 10.1007/s12194-017-0390-9

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  29 in total

1.  Computed tomography in color: NanoK-enhanced spectral CT molecular imaging.

Authors:  Dipanjan Pan; Ewald Roessl; Jens-Peter Schlomka; Shelton D Caruthers; Angana Senpan; Mike J Scott; John S Allen; Huiying Zhang; Grace Hu; Patrick J Gaffney; Eric T Choi; Volker Rasche; Samuel A Wickline; Roland Proksa; Gregory M Lanza
Journal:  Angew Chem Int Ed Engl       Date:  2010-12-10       Impact factor: 15.336

2.  Joint estimation of tissue types and linear attenuation coefficients for photon counting CT.

Authors:  Kento Nakada; Katsuyuki Taguchi; George S K Fung; Kenji Amaya
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

3.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

4.  Estimator for photon counting energy selective x-ray imaging with multibin pulse height analysis.

Authors:  Robert E Alvarez
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

5.  Spatio-energetic cross talk in photon counting detectors: Detector model and correlated Poisson data generator.

Authors:  Katsuyuki Taguchi; Christoph Polster; Okkyun Lee; Karl Stierstorfer; Steffen Kappler
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

6.  The feasibility of a piecewise-linear dynamic bowtie filter.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

7.  Statistical reconstruction of material decomposed data in spectral CT.

Authors:  Carsten O Schirra; Ewald Roessl; Thomas Koehler; Bernhard Brendel; Axel Thran; Dipanjan Pan; Mark A Anastasio; Roland Proksa
Journal:  IEEE Trans Med Imaging       Date:  2013-03-07       Impact factor: 10.048

8.  Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles.

Authors:  David P Cormode; Ewald Roessl; Axel Thran; Torjus Skajaa; Ronald E Gordon; Jens-Peter Schlomka; Valentin Fuster; Edward A Fisher; Willem J M Mulder; Roland Proksa; Zahi A Fayad
Journal:  Radiology       Date:  2010-07-28       Impact factor: 11.105

9.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging.

Authors:  Jan S Iwanczyk; Einar Nygård; Oded Meirav; Jerry Arenson; William C Barber; Neal E Hartsough; Nail Malakhov; Jan C Wessel
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

10.  Detecting vascular biosignatures with a colloidal, radio-opaque polymeric nanoparticle.

Authors:  Dipanjan Pan; Todd A Williams; Angana Senpan; John S Allen; Mike J Scott; Patrick J Gaffney; Samuel A Wickline; Gregory M Lanza
Journal:  J Am Chem Soc       Date:  2009-10-28       Impact factor: 15.419

View more
  17 in total

1.  Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography.

Authors:  Tyler E Curtis; Ryan K Roeder
Journal:  J Med Imaging (Bellingham)       Date:  2019-02-11

Review 2.  Training and Service Provision in Cardiovascular CT: International Challenges and Solutions.

Authors:  E D Nicol; J Shambrook; E Shaw; J Leipsic; L Shaw
Journal:  Curr Cardiol Rep       Date:  2017-10-18       Impact factor: 2.931

Review 3.  Nanoparticle contrast agents for X-ray imaging applications.

Authors:  Jessica C Hsu; Lenitza M Nieves; Oshra Betzer; Tamar Sadan; Peter B Noël; Rachela Popovtzer; David P Cormode
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2020-05-22

4.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

Authors:  Rolf Symons; Daniel S Reich; Mohammadhadi Bagheri; Tyler E Cork; Bernhard Krauss; Stefan Ulzheimer; Steffen Kappler; David A Bluemke; Amir Pourmorteza
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

5.  Pulse pileup analysis for a double-sided silicon strip detector using variable pulse shapes.

Authors:  Jinghui Wang; Linchuan Chen; Mats Persson; Paurakh L Rajbhandary; Praneeth Kandlakunta; Gabriella Carini; Rebecca Fahrig
Journal:  IEEE Trans Nucl Sci       Date:  2019-05-15       Impact factor: 1.679

6.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

7.  Intelligent Reconstruction Algorithm-Based Computed Tomography Images for Automatic Detection of Gastric Tumor.

Authors:  Yuanyuan Zhang; Lisha Chen; Huixin Chen
Journal:  Comput Math Methods Med       Date:  2022-06-28       Impact factor: 2.809

Review 8.  Imaging the Injured Lung: Mechanisms of Action and Clinical Use.

Authors:  Maurizio Cereda; Yi Xin; Alberto Goffi; Jacob Herrmann; David W Kaczka; Brian P Kavanagh; Gaetano Perchiazzi; Takeshi Yoshida; Rahim R Rizi
Journal:  Anesthesiology       Date:  2019-09       Impact factor: 7.892

9.  Assessment of Multienergy Interpixel Coincidence Counters (MEICC) for Charge Sharing Correction or Compensation for Photon Counting Detectors With Boxcar Signals.

Authors:  Katsuyuki Taguchi
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-06-17

Review 10.  Next-Generation Hardware Advances in CT: Cardiac Applications.

Authors:  Alan C Kwan; Amir Pourmorteza; Dan Stutman; David A Bluemke; João A C Lima
Journal:  Radiology       Date:  2020-11-17       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.