Spatio-energetic cross talk in photon counting detectors: Detector model and correlated Poisson data generator.

Katsuyuki Taguchi1, Christoph Polster2, Okkyun Lee1, Karl Stierstorfer3, Steffen Kappler3.   

Abstract

PURPOSE: An x-ray photon interacts with photon counting detectors (PCDs) and generates an electron charge cloud or multiple clouds. The clouds (thus, the photon energy) may be split between two adjacent PCD pixels when the interaction occurs near pixel boundaries, producing a count at both of the pixels. This is called double-counting with charge sharing. (A photoelectric effect with K-shell fluorescence x-ray emission would result in double-counting as well). As a result, PCD data are spatially and energetically correlated, although the output of individual PCD pixels is Poisson distributed. Major problems include the lack of a detector noise model for the spatio-energetic cross talk and lack of a computationally efficient simulation tool for generating correlated Poisson data. A Monte Carlo (MC) simulation can accurately simulate these phenomena and produce noisy data; however, it is not computationally efficient.
METHODS: In this study, the authors developed a new detector model and implemented it in an efficient software simulator that uses a Poisson random number generator to produce correlated noisy integer counts. The detector model takes the following effects into account: (1) detection efficiency; (2) incomplete charge collection and ballistic effect; (3) interaction with PCDs via photoelectric effect (with or without K-shell fluorescence x-ray emission, which may escape from the PCDs or be reabsorbed); and (4) electronic noise. The correlation was modeled by using these two simplifying assumptions: energy conservation and mutual exclusiveness. The mutual exclusiveness is that no more than two pixels measure energy from one photon. The effect of model parameters has been studied and results were compared with MC simulations. The agreement, with respect to the spectrum, was evaluated using the reduced χ2 statistics or a weighted sum of squared errors, χred2(≥1), where χred2=1 indicates a perfect fit.
RESULTS: The model produced spectra with flat field irradiation that qualitatively agree with previous studies. The spectra generated with different model and geometry parameters allowed for understanding the effect of the parameters on the spectrum and the correlation of data. The agreement between the model and MC data was very strong. The mean spectra with 90 keV and 140 kVp agreed exceptionally well: χred2 values were 1.049 with 90 keV data and 1.007 with 140 kVp data. The degrees of cross talk (in terms of the relative increase from single pixel irradiation to flat field irradiation) were 22% with 90 keV and 19% with 140 kVp for MC simulations, while they were 21% and 17%, respectively, for the model. The covariance was in strong agreement qualitatively, although it was overestimated. The noisy data generation was very efficient, taking less than a CPU minute as opposed to CPU hours for MC simulators.
CONCLUSIONS: The authors have developed a novel, computationally efficient PCD model that takes into account double-counting and resulting spatio-energetic correlation between PCD pixels. The MC simulation validated the accuracy.

Entities:  

Mesh:

Year:  2016        PMID: 27908175     DOI: 10.1118/1.4966699

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

2.  A framework for performance characterization of energy-resolving photon-counting detectors.

Authors:  Mats Persson; Paurakh L Rajbhandary; Norbert J Pelc
Journal:  Med Phys       Date:  2018-10-12       Impact factor: 4.071

3.  Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans.

Authors:  Rolf Symons; Amir Pourmorteza; Veit Sandfort; Mark A Ahlman; Tracy Cropper; Marissa Mallek; Steffen Kappler; Stefan Ulzheimer; Mahadevappa Mahesh; Elizabeth C Jones; Ashkan A Malayeri; Les R Folio; David A Bluemke
Journal:  Radiology       Date:  2017-07-28       Impact factor: 11.105

Review 4.  Energy-sensitive photon counting detector-based X-ray computed tomography.

Authors:  Katsuyuki Taguchi
Journal:  Radiol Phys Technol       Date:  2017-01-30

5.  Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.

Authors:  Xu Ji; Kevin Treb; Ke Li
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 3.609

Review 6.  Next-Generation Hardware Advances in CT: Cardiac Applications.

Authors:  Alan C Kwan; Amir Pourmorteza; Dan Stutman; David A Bluemke; João A C Lima
Journal:  Radiology       Date:  2020-11-17       Impact factor: 11.105

7.  Model-based pulse pileup and charge sharing compensation for photon counting detectors: A simulation study.

Authors:  Katsuyuki Taguchi; Christoph Polster; W Paul Segars; Nafi Aygun; Karl Stierstorfer
Journal:  Med Phys       Date:  2022-07-04       Impact factor: 4.506

8.  Frequency-dependent signal and noise in spectroscopic x-ray imaging.

Authors:  Jesse Tanguay; Jinwoo Kim; Ho Kyung Kim; Kris Iniewski; Ian A Cunningham
Journal:  Med Phys       Date:  2020-04-22       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.