Literature DB >> 20691056

Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture.

Sarunas Tarasevicius1, Mantas Busevicius, Otto Robertsson, Hans Wingstrand.   

Abstract

BACKGROUND: Hip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral neck fracture patients operated with a posterior approach with cemented conventional or dual articulation acetabular components.
METHODS: We compared the dislocation rate in 56 consecutive patients operated with conventional (single mobility) cemented acetabular components to that in 42 consecutive patients operated with dual articulation acetabular components. All the patients were operated via posterior approach and were followed up to one year postoperatively.
RESULTS: There were 8 dislocations in the 56 patients having conventional components as compared to no dislocations in those 42 having dual articulation components (p = 0.01). The groups were similar with respect to age and gender distribution.
CONCLUSIONS: We conclude that the use of a cemented dual articulation acetabular component significantly reduces the dislocation rates in femoral neck fracture patients operated via posterior approach.

Entities:  

Mesh:

Year:  2010        PMID: 20691056      PMCID: PMC2922087          DOI: 10.1186/1471-2474-11-175

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


  12 in total

1.  Displaced femoral neck fractures in the elderly: outcomes and cost effectiveness.

Authors:  R Iorio; W L Healy; D W Lemos; D Appleby; C A Lucchesi; K J Saleh
Journal:  Clin Orthop Relat Res       Date:  2001-02       Impact factor: 4.176

Review 2.  Instability after total hip arthroplasty.

Authors:  B F Morrey
Journal:  Orthop Clin North Am       Date:  1992-04       Impact factor: 2.472

3.  Femoral head diameter affects the revision rate in total hip arthroplasty: an analysis of 1,720 hip replacements with 9-21 years of follow-up.

Authors:  Sarunas Tarasevicius; Uldis Kesteris; Otto Robertsson; Hans Wingstrand
Journal:  Acta Orthop       Date:  2006-10       Impact factor: 3.717

4.  Acetabular osteolysis and migration in bipolar arthroplasty of the hip: five- to 13-year follow-up study.

Authors:  K Nakata; K Ohzono; K Masuhara; M Matsui; K Hiroshima; T Ochi
Journal:  J Bone Joint Surg Br       Date:  1997-03

5.  Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years.

Authors:  Paul F Lachiewicz; Daniel S Heckman; Elizabeth S Soileau; Jimmi Mangla; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

6.  Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients.

Authors:  Sarunas Tarasevicius; Otto Robertsson; Uldis Kesteris; Romas Jonas Kalesinskas; Hans Wingstrand
Journal:  Acta Orthop       Date:  2008-08       Impact factor: 3.717

7.  Risk factors for revision for early dislocation in total hip arthroplasty.

Authors:  Jonathan L Conroy; Sarah L Whitehouse; Stephen E Graves; Nicole L Pratt; Philip Ryan; Ross W Crawford
Journal:  J Arthroplasty       Date:  2008-03-07       Impact factor: 4.757

Review 8.  Advances in the treatment of intracapsular hip fractures in the elderly.

Authors:  Ross K Leighton; Andrew H Schmidt; Pamela Collier; Kelly Trask
Journal:  Injury       Date:  2007-09       Impact factor: 2.586

9.  Dislocation of hemiarthroplasty after femoral neck fracture: better outcome after the anterolateral approach in a prospective cohort study on 739 consecutive hips.

Authors:  Anders Enocson; Jan Tidermark; Hans Tornkvist; Lasse J Lapidus
Journal:  Acta Orthop       Date:  2008-04       Impact factor: 3.717

10.  Dislocation of total hip replacement in patients with fractures of the femoral neck.

Authors:  Anders Enocson; Carl-Johan Hedbeck; Jan Tidermark; Hans Pettersson; Sari Ponzer; Lasse J Lapidus
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more
  31 in total

1.  Choice of approach, but not femoral head size, affects revision rate due to dislocations in THA after femoral neck fracture: results from the Lithuanian Arthroplasty Register.

Authors:  Algimantas Cebatorius; Otto Robertsson; Justinas Stucinskas; Alfredas Smailys; Linas Leonas; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2014-12-16       Impact factor: 3.075

2.  Guest Editorial: An Appeal for Evidenced-based Care and Adoption of Best Practices in the Management of Displaced Femoral Neck Fractures.

Authors:  Charles N Cornell
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

Review 3.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 4.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

Review 5.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

6.  What factors affect posterior dislocation distance in THA?

Authors:  Jim Nevelos; Aaron Johnson; Christopher Heffernan; James Macintyre; David C Markel; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

7.  Short-term outcome after total hip arthroplasty using dual-mobility cup: report from Lithuanian Arthroplasty Register.

Authors:  Sarunas Tarasevicius; Alfredas Smailys; Kazimieras Grigaitis; Otto Robertsson; Justinas Stucinskas
Journal:  Int Orthop       Date:  2017-01-12       Impact factor: 3.075

8.  Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

Authors:  Chahine Assi; Elie El-Najjar; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-01-10       Impact factor: 3.075

9.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

Review 10.  Risk of revision and dislocation in single, dual mobility and large femoral head total hip arthroplasty: systematic review and network meta-analysis.

Authors:  Kwanchai Pituckanotai; Alisara Arirachakaran; Harit Tuchinda; Chinundorn Putananon; Nitiphol Nualsalee; Kittipong Setrkraising; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.