Literature DB >> 27826763

Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up : A prospective and comparative series.

Jean-Marc Puch1, Guy Derhi2, Loys Descamps1, Régis Verdier3, Jacques H Caton4.   

Abstract

PURPOSE: We report clinical and radiological outcome of a dual mobility cup (DMC) of 2nd generation after a minimum of ten year-follow-up (FU). The goal of this work was to compare the results of this DMC in patients aged less than 55 years and in patients aged more than 55 years.
METHODS: From 2000 to 2005, a prospective and consecutive series of 119 THAs with a cementless DMC of 2nd generation (GIROS) were performed in patients aged less than 55 years and 444 in patients aged more than 55 years.
RESULTS: The mean FU was 11 years (8 to 15 years). Survivorships (failure of both components or cup loosening) were not different between patients aged less than 55 years and patients aged more than 55 years. There was no dislocation. DEVANE classification, Harris, PMA and Oxford scores improved after THA but no difference could be found between between < 55 years and > 55 years patients.
CONCLUSION: These results are better than those of first generation (BOUSQUET) DMC (77 % of survival rate at 20 years of FU). These results are in the same agreement than those of the literature: 99 % of survival rate at 14.2 years of FU for KERBOULL with a low friction arthroplasty and 96.5 % at ten years of FU for ceramic/ceramic bearing (R CHANA). The DMC for young patient is a relevant surgical option with no dislocation and excellent clinical results and survival rate at more than ten years of FU.

Entities:  

Keywords:  Dislocation; Dual mobility cup; Less than 55 years; Long term results; Total hip arthroplasty

Mesh:

Year:  2016        PMID: 27826763     DOI: 10.1007/s00264-016-3325-x

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  20 in total

1.  The dual mobility socket concept: experience with 668 cases.

Authors:  Claude Vielpeau; Benoit Lebel; Ludovic Ardouin; Gilles Burdin; Christine Lautridou
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

2.  Evora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.

Authors:  S Leclercq; J Y Benoit; J P de Rosa; E Tallier; C Leteurtre; P H Girardin
Journal:  Orthop Traumatol Surg Res       Date:  2013-10-29       Impact factor: 2.256

3.  Is alumina-on-alumina ceramic bearings total hip replacement the right choice in patients younger than 50 years of age? A 7- to 15-year follow-up study.

Authors:  P Boyer; D Huten; P Loriaut; V Lestrat; C Jeanrot; P Massin
Journal:  Orthop Traumatol Surg Res       Date:  2010-10       Impact factor: 2.256

4.  Stem fixation in the Charnley low-friction arthroplasty in young patients using an intramedullary bone block.

Authors:  B M Wroblewski; P A Fleming; R M Hall; P D Siney
Journal:  J Bone Joint Surg Br       Date:  1998-03

5.  Mid- to long-term outcome of cementless total hip arthroplasty in younger patients.

Authors:  Fernando Almeida; Laura Pino; Antonio Silvestre; Francisco Gomar
Journal:  J Orthop Surg (Hong Kong)       Date:  2010-08       Impact factor: 1.118

6.  Ceramic-on-ceramic bearings in young patients: outcomes and activity levels at minimum ten-year follow-up.

Authors:  R Chana; M Facek; S Tilley; W K Walter; B Zicat; W L Walter
Journal:  Bone Joint J       Date:  2013-12       Impact factor: 5.082

7.  The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty.

Authors:  Daniel J Berry; Marius von Knoch; Cathy D Schleck; W Scott Harmsen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

8.  A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk.

Authors:  Jacques H Caton; Jean Louis Prudhon; André Ferreira; Thierry Aslanian; Régis Verdier
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

9.  Long-term results of Charnley-Kerboull hip arthroplasty in patients younger than 50 years.

Authors:  Luc Kerboull; Moussa Hamadouche; Jean Pierre Courpied; Marcel Kerboull
Journal:  Clin Orthop Relat Res       Date:  2004-01       Impact factor: 4.176

10.  Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation.

Authors:  P Bizot; D Hannouche; R Nizard; J Witvoet; L Sedel
Journal:  J Bone Joint Surg Br       Date:  2004-03
View more
  13 in total

1.  Dual-mobility cup: a new French revolution.

Authors:  Jacques Henri Caton; André Ferreira
Journal:  Int Orthop       Date:  2017-02-14       Impact factor: 3.075

2.  All dual mobility cups are not the same.

Authors:  Thierry Aslanian
Journal:  Int Orthop       Date:  2017-01-18       Impact factor: 3.075

Review 3.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 4.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

5.  Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

Authors:  Chahine Assi; Elie El-Najjar; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-01-10       Impact factor: 3.075

6.  Intraprosthetic dislocation of dual mobility total hip arthroplasty: still occurring?

Authors:  Thomas Neri; Bertrand Boyer; Jean Geringer; Alexandre Di Iorio; Jacques H Caton; Remi PhiIippot; Frederic Farizon
Journal:  Int Orthop       Date:  2018-07-19       Impact factor: 3.075

7.  Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series.

Authors:  Ji-Hyo Hwang; Sang-Min Kim; Kwang-Jun Oh; Yeesuk Kim
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

8.  Effect of changing femoral head diameter on bony and prosthetic jumping angles.

Authors:  Takaaki Ohmori; Tamon Kabata; Yoshitomo Kajino; Daisuke Inoue; Tadashi Taga; Takashi Yamamoto; Tomoharu Takagi; Junya Yoshitani; Takuro Ueno; Ken Ueoka; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-30

9.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

10.  Letter to the editor on "Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels".

Authors:  Emanuela Castiello; Luca Amendola; Paolo Barca; Domenico Tigani; Jacques H Caton; Thomas Neri; Jean Louis Prudhon
Journal:  Arthroplast Today       Date:  2020-02-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.