Literature DB >> 22700131

A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions.

Roberto Civinini1, Christian Carulli, Fabrizio Matassi, Lorenzo Nistri, Massimo Innocenti.   

Abstract

BACKGROUND: Isolated acetabular revisions using standard cups are at risk of dislocation. The introduction of a nonconstrained dual-mobility cup was designed to improve prosthetic stability without increasing loosening rates, but it is unclear whether the risk of dislocation is reduced. QUESTIONS/PURPOSES: We therefore determined: (1) if the rate of dislocation in isolated acetabular revisions is lower with a dual-mobility cup, (2) implant survival, (3) patient function, and (4) radiographic incidence of migration, loosening, and osteolysis.
METHODS: We prospectively followed 33 selected patients who underwent isolated acetabular revisions with a minimum of 2 years' followup (mean, 3 years; range, 2-5 years). In 24 patients a stainless steel dual-mobility cup was cemented into an antiprotrusio cage, whereas in nine we used a hyaluronan dual-mobility revision cup with a foramen hook and superior and posterior flanges screw fixations. We determined Harris hip (HHS) and WOMAC scores and examined radiographs for migration, loosening, and osteolysis.
RESULTS: There were no dislocations. Survivorship rates of the femoral and acetabular components were 97% at 5 years; the rerevision rate for any reason was 3%. At last followup, the mean HHS increased from 48 points preoperatively to 86 points. No patients had progressive osteolysis, component migration, or loosening on radiographs.
CONCLUSION: In this select group of isolated acetabular revisions, our data suggest the use of a dual-mobility cup reduced the risk of dislocation without increasing loosening from 2 to 5 years. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22700131      PMCID: PMC3492645          DOI: 10.1007/s11999-012-2428-y

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  39 in total

1.  The fate of stable femoral components retained during isolated acetabular revision: a six-to-twelve-year follow-up study.

Authors:  Joseph T Moskal; Francis H Shen; Thomas E Brown
Journal:  J Bone Joint Surg Am       Date:  2002-02       Impact factor: 5.284

Review 2.  The use of constrained components in total hip arthroplasty.

Authors:  Paul F Lachiewicz; Scott S Kelley
Journal:  J Am Acad Orthop Surg       Date:  2002 Jul-Aug       Impact factor: 3.020

3.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

4.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

5.  Revision of the acetabular component with an uncemented Harris-Galante porous-coated prosthesis.

Authors:  M Tanzer; D Drucker; M Jasty; M McDonald; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-08       Impact factor: 5.284

Review 6.  Exposure for revision: total hip replacement.

Authors:  Andrew H Glassman
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

7.  Factors influencing the longer-term survival of uncemented acetabular components used in total hip revisions.

Authors:  Carroll P Jones; Paul F Lachiewicz
Journal:  J Bone Joint Surg Am       Date:  2004-02       Impact factor: 5.284

8.  Hip disability and osteoarthritis outcome score. An extension of the Western Ontario and McMaster Universities Osteoarthritis Index.

Authors:  Maria Klässbo; Eva Larsson; Eva Mannevik
Journal:  Scand J Rheumatol       Date:  2003       Impact factor: 3.641

9.  Isolated acetabular revision with use of the Harris-Galante Cementless Component. Study with intermediate-term follow-up.

Authors:  Amir A Jamali; Danton S Dungy; Arthur Mark; Steven Schule; William H Harris
Journal:  J Bone Joint Surg Am       Date:  2004-08       Impact factor: 5.284

10.  Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey.

Authors:  Daniel Dindo; Nicolas Demartines; Pierre-Alain Clavien
Journal:  Ann Surg       Date:  2004-08       Impact factor: 12.969

View more
  26 in total

Review 1.  Porous metal for orthopedics implants.

Authors:  Fabrizio Matassi; Alessandra Botti; Luigi Sirleo; Christian Carulli; Massimo Innocenti
Journal:  Clin Cases Miner Bone Metab       Date:  2013-05

2.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

Review 3.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

Review 4.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 5.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

6.  A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty.

Authors:  Elliot Sappey-Marinier; Anthony Viste; Yoann Blangero; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2019-01-05       Impact factor: 3.075

7.  Repeated posterior dislocation of total hip arthroplasty after spinal corrective long fusion with pelvic fixation.

Authors:  Hiroki Furuhashi; Daisuke Togawa; Hiroshi Koyama; Hironobu Hoshino; Tatsuya Yasuda; Yukihiro Matsuyama
Journal:  Eur Spine J       Date:  2016-11-17       Impact factor: 3.134

8.  Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

Authors:  Justinas Stucinskas; Tomas Kalvaitis; Alfredas Smailys; Otto Robertsson; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2017-12-02       Impact factor: 3.075

9.  Dual mobility constructs in revision total hip arthroplasty: survivorship analysis in recurrent dislocation versus other indications at three to twelve-year follow-up.

Authors:  Nicolas de l'Escalopier; Valérie Dumaine; Guillaume Auberger; Antoine Babinet; Jean-Pierre Courpied; Philippe Anract; Moussa Hamadouche
Journal:  Int Orthop       Date:  2019-11-22       Impact factor: 3.075

10.  Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.

Authors:  Colin T Penrose; Thorsten M Seyler; Samuel S Wellman; Michael P Bolognesi; Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.