Preclinical positron emission tomography scanner based on a monolithic annulus of scintillator: initial design study.

Alexander V Stolin1, Peter F Martone1, Gangadhar Jaliparthi1, Raymond R Raylman1.   

Abstract

Positron emission tomography (PET) scanners designed for imaging of small animals have transformed translational research by reducing the necessity to invasively monitor physiology and disease progression. Virtually all of these scanners are based on the use of pixelated detector modules arranged in rings. This design, while generally successful, has some limitations. Specifically, use of discrete detector modules to construct PET scanners reduces detection sensitivity and can introduce artifacts in reconstructed images, requiring the use of correction methods. To address these challenges, and facilitate measurement of photon depth-of-interaction in the detector, we investigated a small animal PET scanner (called AnnPET) based on a monolithic annulus of scintillator. The scanner was created by placing 12 flat facets around the outer surface of the scintillator to accommodate placement of silicon photomultiplier arrays. Its performance characteristics were explored using Monte Carlo simulations and sections of the NEMA NU4-2008 protocol. Results from this study revealed that AnnPET's reconstructed spatial resolution is predicted to be [Formula: see text] full width at half maximum in the radial, tangential, and axial directions. Peak detection sensitivity is predicted to be 10.1%. Images of simulated phantoms (mini-hot rod and mouse whole body) yielded promising results, indicating the potential of this system for enhancing PET imaging of small animals.

Entities:  

Keywords:  Monte Carlo simulation; positron emission tomography; preclinical; scanner design

Year:  2017        PMID: 28097210      PMCID: PMC5217083          DOI: 10.1117/1.JMI.4.1.011007

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  54 in total

1.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

2.  National Electrical Manufacturers Association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner.

Authors:  Istvan Szanda; Jane Mackewn; Gergely Patay; Peter Major; Kavitha Sunassee; Gregory E Mullen; Gabor Nemeth; York Haemisch; Philip J Blower; Paul K Marsden
Journal:  J Nucl Med       Date:  2011-10-03       Impact factor: 10.057

3.  On the assessment of spatial resolution of PET systems with iterative image reconstruction.

Authors:  Kuang Gong; Simon R Cherry; Jinyi Qi
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

4.  First results from the high-resolution mouseSPECT annular scintillation camera.

Authors:  Andrew L Goertzen; Douglas W Jones; Jurgen Seidel; King Li; Michael V Green
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

5.  Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners.

Authors:  C Ross Schmidtlein; Assen S Kirov; Sadek A Nehmeh; Yusuf E Erdi; John L Humm; Howard I Amols; Luc M Bidaut; Alex Ganin; Charles W Stearns; David L McDaniel; Klaus A Hamacher
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

6.  A DOI Detector With Crystal Scatter Identification Capability for High Sensitivity and High Spatial Resolution PET Imaging.

Authors:  Z Gu; D L Prout; R W Silverman; H Herman; A Dooraghi; A F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2015-06       Impact factor: 1.679

7.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

Authors:  C S Levin; E J Hoffman
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

8.  Small animal MRI at 0.35 Tesla: growth and morphology of intra-organ murine tumors.

Authors:  T M Button; R J Fiel; M Goldrosen; N Paolini
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

9.  Performance evaluation of PETbox: a low cost bench top preclinical PET scanner.

Authors:  Hui Zhang; Qinan Bao; Nam T Vu; Robert W Silverman; Richard Taschereau; Brittany N Berry-Pusey; Ali Douraghy; Fernando R Rannou; David B Stout; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2011-10       Impact factor: 3.488

10.  TandemPET- A High Resolution, Small Animal, Virtual Pinhole-Based PET Scanner: Initial Design Study.

Authors:  Raymond R Raylman; Alexander V Stolin; Peter F Martone; Mark F Smith
Journal:  IEEE Trans Nucl Sci       Date:  2015-10-29       Impact factor: 1.679

View more
  5 in total

1.  A combined positron emission tomography (PET)-electron paramagnetic resonance imaging (EPRI) system: initial evaluation of a prototype scanner.

Authors:  Mark Tseytlin; Alexander V Stolin; Priyaankadevi Guggilapu; Andrey A Bobko; Valery V Khramtsov; Oxana Tseytlin; Raymond R Raylman
Journal:  Phys Med Biol       Date:  2018-05-16       Impact factor: 3.609

2.  Calibration Methodology of an Edgeless PET System Prototype.

Authors:  Marta Freire; Andrea Gonzalez-Montoro; Gabriel Cañizares; Stuart S Berr; Luis F Vidal; Liczandro Hernandez; Antonio J Gonzalez
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2021-08-12

3.  Experimental validation of a rodent PET scanner prototype based on a single LYSO crystal tube.

Authors:  Marta Freire; Andrea Gonzalez-Montoro; Gabriel Cañizares; Ahmadreza Rezaei; Johan Nuyts; Stuart S Berr; Mark B Williams; Jose M Benlloch; Antonio J Gonzalez
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-11-01

4.  Deep residual-convolutional neural networks for event positioning in a monolithic annular PET scanner.

Authors:  Gangadhar Jaliparthi; Peter F Martone; Alexander V Stolin; Raymond R Raylman
Journal:  Phys Med Biol       Date:  2021-07-12       Impact factor: 3.609

5.  Feasibility Study of a Small Animal PET Insert Based on a Single LYSO Monolithic Tube.

Authors:  Antonio J Gonzalez; Stuart S Berr; Gabriel Cañizares; Andrea Gonzalez-Montoro; Abel Orero; Carlos Correcher; Ahmadreza Rezaei; Johan Nuyts; Filomeno Sanchez; Stan Majewski; Jose M Benlloch
Journal:  Front Med (Lausanne)       Date:  2018-11-28