TandemPET- A High Resolution, Small Animal, Virtual Pinhole-Based PET Scanner: Initial Design Study.

Raymond R Raylman1, Alexander V Stolin1, Peter F Martone1, Mark F Smith2.   

Abstract

Mice are the perhaps the most common species of rodents used in biomedical research, but many of the current generation of small animal PET scanners are non-optimal for imaging these small rodents due to their relatively low resolution. Consequently, a number of researchers have investigated the development of high-resolution scanners to address this need. In this investigation, the design of a novel, high-resolution system based on the dual-detector, virtual-pinhole PET concept was explored via Monte Carlo simulations. Specifically, this system, called TandemPET, consists of a 5 cm × 5 cm high-resolution detector made-up of a 90 × 90 array of 0.5 mm × 0.5 mm × 10 mm (pitch= 0.55 mm) LYSO detector elements in coincidence with a lower resolution detector consisting of a 68 × 68 array of 1.5 mm × 1.5 mm × 10 mm LYSO detector elements (total size= 10.5 cm × 10.5 cm). Analyses indicated that TandemPET's optimal geometry is to position the high-resolution detector 3 cm from the center-of-rotation, with the lower resolution detector positioned 9 cm from center. Measurements using modified NEMA NU4-2008-based protocols revealed that the spatial resolution of the system is ~0.5 mm FWHM, after correction of positron range effects. Peak sensitivity is 2.1%, which is comparable to current small animal PET scanners. Images from a digital mouse brain phantom demonstrated the potential of the system for identifying important neurological structures.

Entities:  

Keywords:  Monte Carlo Simulation; PET Instrumentation; Small Animal Imaging

Year:  2015        PMID: 27041767      PMCID: PMC4813808          DOI: 10.1109/TNS.2015.2482459

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  32 in total

Review 1.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

2.  First results from the high-resolution mouseSPECT annular scintillation camera.

Authors:  Andrew L Goertzen; Douglas W Jones; Jurgen Seidel; King Li; Michael V Green
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

3.  Virtual-pinhole PET.

Authors:  Yuan-Chuan Tai; Heyu Wu; Debashish Pal; Joseph A O'Sullivan
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

4.  Constrained Fourier space method for compensation of missing data in emission computed tomography.

Authors:  J S Karp; G Muehllehner; R M Lewitt
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

5.  Performance comparison of Si-PM-based block detectors with different pixel sizes for an ultrahigh-resolution small-animal PET system.

Authors:  Seiichi Yamamoto; Hiroshi Watabe; Jun Hatazawa
Journal:  Phys Med Biol       Date:  2011-09-21       Impact factor: 3.609

6.  A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals.

Authors:  S I Ziegler; B J Pichler; G Boening; M Rafecas; W Pimpl; E Lorenz; N Schmitz; M Schwaiger
Journal:  Eur J Nucl Med       Date:  2001-02

7.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

Authors:  C S Levin; E J Hoffman
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

8.  Small animal MRI at 0.35 Tesla: growth and morphology of intra-organ murine tumors.

Authors:  T M Button; R J Fiel; M Goldrosen; N Paolini
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

9.  Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

Authors:  Y Gu; J L Matteson; R T Skelton; A C Deal; E A Stephan; F Duttweiler; T M Gasaway; C S Levin
Journal:  Phys Med Biol       Date:  2011-02-18       Impact factor: 3.609

10.  Micro insert: a prototype full-ring PET device for improving the image resolution of a small-animal PET scanner.

Authors:  Heyu Wu; Debashish Pal; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  J Nucl Med       Date:  2008-09-15       Impact factor: 10.057

View more
  3 in total

1.  Preclinical positron emission tomography scanner based on a monolithic annulus of scintillator: initial design study.

Authors:  Alexander V Stolin; Peter F Martone; Gangadhar Jaliparthi; Raymond R Raylman
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-05

2.  System resolution versus image uncertainty for positron emission tomography scanners.

Authors:  Andrej Studen; Neal Clinthorne
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-13

Review 3.  Integrating Small Animal Irradiators withFunctional Imaging for Advanced Preclinical Radiotherapy Research.

Authors:  Mihaela Ghita; Kathryn H Brown; Olivia J Kelada; Edward E Graves; Karl T Butterworth
Journal:  Cancers (Basel)       Date:  2019-02-01       Impact factor: 6.639

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.