Literature DB >> 30612171

A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty.

Elliot Sappey-Marinier1, Anthony Viste2,3,4,5, Yoann Blangero6, Romain Desmarchelier1, Michel-Henri Fessy1,6,7,8.   

Abstract

PURPOSE: Dislocation and peri-prosthetic fracture (PPF) are major reasons for revision THA (total hip arthroplasty). The main advantage of dual mobility (DM) cups is to minimize the incidence of dislocation compared to single mobility (SM) cups. We hypothesized that the use of DM would lead to an increased risk of PPF because of its greater stability. In contrast, standard cups would be at higher risk of dislocation.
METHODS: A retrospective comparative study was performed in our institution including 126 revision THAs between January 2013 and December 2017. Collected data included gender, age, BMI, Parker score, ASA score, the etiology for primary THA, type of cup (SM or DM), cortical index, Noble index, and the stem fixation.
RESULTS: Overall, 53 standard and 73 DM cups were included for study. In the dislocation group, 29 had standard cups (83%) and 6 had DM cups (17%). Dislocation was 12-fold higher in SM cups (p < 0.001). In the PPF group, 24 had standard cups (26%) and 67 had DM cups (74%). PFF was 12-fold higher for DM cups (p < 0.001). A higher Parker score and a higher cortical index had a protective effect on the risk of PPF (OR = 0.76 (p = 0.03), OR = 0.57 (p = 0.048)).
CONCLUSION: The use of DM increased hip stability but led to a higher rate of PPF by load transfer on the femur. Further studies with larger cohort and follow-up are needed to confirm these findings and measure the incidence of these complications.

Entities:  

Keywords:  Dislocation; Dual mobility; Peri-prosthetic fracture; Standard cups; Total hip arthroplasty

Mesh:

Year:  2019        PMID: 30612171     DOI: 10.1007/s00264-018-4279-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  The dual mobility cup: what problems does it solve?

Authors:  L Matsen Ko; W J Hozack
Journal:  Bone Joint J       Date:  2016-01       Impact factor: 5.082

2.  Economic burden of revision hip and knee arthroplasty in Medicare enrollees.

Authors:  K L Ong; F S Mowat; N Chan; E Lau; M T Halpern; S M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2006-05       Impact factor: 4.176

Review 3.  The operation of the century: total hip replacement.

Authors:  Ian D Learmonth; Claire Young; Cecil Rorabeck
Journal:  Lancet       Date:  2007-10-27       Impact factor: 79.321

4.  What are the causes for failures of primary hip arthroplasties in France?

Authors:  Christian Delaunay; Moussa Hamadouche; Julien Girard; Alain Duhamel
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

5.  Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

Authors:  Justinas Stucinskas; Tomas Kalvaitis; Alfredas Smailys; Otto Robertsson; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2017-12-02       Impact factor: 3.075

6.  Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.

Authors:  Chad D Watts; Matthew P Abdel; David G Lewallen; Daniel J Berry; Arlen D Hanssen
Journal:  Clin Orthop Relat Res       Date:  2014-12-12       Impact factor: 4.176

7.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

8.  Total hip replacement after femoral neck fractures in elderly patients : results of 8,577 fractures reported to the Norwegian Arthroplasty Register.

Authors:  Jan-Erik Gjertsen; Stein Atle Lie; Jonas M Fevang; Leif Ivar Havelin; Lars B Engesaeter; Tarjei Vinje; Ove Furnes
Journal:  Acta Orthop       Date:  2007-08       Impact factor: 3.717

9.  Revision total hip arthroplasty with a Kerboull plate: comparative outcomes using standard versus dual mobility cups.

Authors:  Chahine Assi; Jacques Caton; Wissam Fawaz; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2018-10-29       Impact factor: 3.075

10.  Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup.

Authors:  Thibault Vermersch; Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2015-09-07       Impact factor: 3.075

View more
  2 in total

1.  Third generation Dual Mobility Cups: could be the future in total hip arthroplasty? A five-year experience with dualis.

Authors:  Stefania Paderni; Carlotta Pari; Filippo Raggini; Carlo Busatto; Elena Delmastro; Alberto Belluati
Journal:  Acta Biomed       Date:  2022-03-10

2.  Risk factors for dislocation after bipolar hemiarthroplasty: a retrospective case-control study of patients with CT data.

Authors:  Tilman Graulich; Pascal Graeff; Ashish Jaiman; Stine Nicolaides; Tarek Omar Pacha; Marcus Örgel; Christian Macke; Mohamed Omar; Christian Krettek; Emmanouil Liodakis
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-10-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.