Literature DB >> 8156674

Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management.

R S Turner1.   

Abstract

Twenty-five dislocations occurred after 561 total hip arthroplasties performed by the author from 1971 to 1992. Acetabular shell and liner loosening must be differentiated from true dislocations. The dislocation rate of 5.49% in female patients was higher than the 2.8% rate in male patients. The 4.76% rate after 84 total hip revisions was slightly higher than the 3.98% rate after 477 primary replacements. No dislocations occurred using the anterolateral approach for 53 patients. Dislocation rates varied using different prosthetic systems for 508 patients who had the posterolateral approach used. Femoral prostheses with larger neck diameters were more prone to dislocation. These differences were not statistically significant with the sample sizes used, according to the chi square test for equality of proportions. Fluoroscopy aided reduction of one multiplanar recurrent case. Single hip spica abduction casts with and without knee hinges used for three to four months, along with abduction isometric exercises, led to stability in six recurrent cases.

Entities:  

Mesh:

Year:  1994        PMID: 8156674

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  Implementing capsule representation in a total hip dislocation finite element model.

Authors:  Kristofer J Stewart; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2004

2.  The dual mobility socket concept: experience with 668 cases.

Authors:  Claude Vielpeau; Benoit Lebel; Ludovic Ardouin; Gilles Burdin; Christine Lautridou
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

3.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

4.  Computer-assisted versus manual alignment in THA: a probabilistic approach to range of motion.

Authors:  Anthony J Petrella; Joshua Q Stowe; Darryl D D'Lima; Paul J Rullkoetter; Peter J Laz
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

5.  [Diagnostics and therapy of luxation after total hip arthroplasty].

Authors:  B Preininger; F Haschke; C Perka
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

6.  Bony impingement limits design-related increases in hip range of motion.

Authors:  Adam Bunn; Clifford W Colwell; Darryl D D'Lima
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

7.  Impingement in Total Hip Replacement: Mechanisms and Consequences.

Authors:  Thomas D Brown; John J Callaghan
Journal:  Curr Orthop       Date:  2008-12-01

8.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Dislocation following total hip replacement: the Avon Orthopaedic Centre experience.

Authors:  Ashley W Blom; Mark Rogers; Adrian H Taylor; Giles Pattison; Sarah Whitehouse; Gordon C Bannister
Journal:  Ann R Coll Surg Engl       Date:  2008-09-30       Impact factor: 1.891

10.  Dislocation after total hip arthroplasty with 28 and 32-mm femoral head.

Authors:  Einar Amlie; Øystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-05-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.