Literature DB >> 16781444

Constrained liners in revision total hip arthroplasty: an overuse syndrome: in the affirmative.

Kevin B Fricka1, Amanda Marshall, Wayne G Paprosky.   

Abstract

Instability after primary and revision total hip arthroplasty continues to be problematic for the surgeon. The use of constrained liners, which use a locking mechanism to capture the femoral head, has increased to help manage this problem. Constrained liners, however, present problems with acetabular component loosening, dissociation of the liner/shell interface, failure by breakage, and excessive polyethylene wear. Rather than resort to constrained liners, our approach has been to restore joint stability with large-diameter femoral heads. The advantages are increased range of motion due to more favorable head/neck ratio, increased resistance to dislocation due to increased jump distance, and the avoidance of skirted femoral heads. With the addition of cross-linked polyethylene, the volumetric wear associated with large heads is much decreased and makes this a viable option today.

Entities:  

Mesh:

Year:  2006        PMID: 16781444     DOI: 10.1016/j.arth.2006.02.100

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  13 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty.

Authors:  Marion Opperer; Yuo-yu Lee; Francisco Nally; Alvaro Blanes Perez; Kaveh Goudarz-Mehdikhani; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

3.  Are abductor muscle quality and previous revision surgery predictors of constrained liner failure in hip arthroplasty?

Authors:  Michael G Zywiel; Loi'y H Mustafa; Peter M Bonutti; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-20       Impact factor: 3.075

Review 4.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

Review 5.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

6.  Instability after total hip arthroplasty.

Authors:  Brian C Werner; Thomas E Brown
Journal:  World J Orthop       Date:  2012-08-18

7.  Can Dislocation of a Constrained Liner Be Salvaged With Dual-mobility Constructs in Revision THA?

Authors:  Brian P Chalmers; Graham D Pallante; Michael J Taunton; Rafael J Sierra; Robert T Trousdale
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

Review 8.  Dual Mobility in Total Hip Arthroplasty: Biomechanics, Indications and Complications-Current Concepts.

Authors:  Nilesh Patil; Prashant Deshmane; Ajit Deshmukh; Christopher Mow
Journal:  Indian J Orthop       Date:  2021-10-13       Impact factor: 1.033

9.  Outcome and risk factors of failures associated with revision total hip arthroplasty for recurrent dislocation.

Authors:  Christian Klemt; Wenhao Chen; Georges Bounajem; Venkatsaiakhil Tirumala; Liang Xiong; Young-Min Kwon
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-18       Impact factor: 2.928

10.  Mathematical evaluation of jumping distance in total hip arthroplasty: influence of abduction angle, femoral head offset, and head diameter.

Authors:  Elhadi Sariali; Jean Yves Lazennec; Frederic Khiami; Yves Catonné
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717