Literature DB >> 27734178

Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Caitlin Martin1, Wei Sun2.   

Abstract

Transcatheter aortic valve (TAV) implantation within a failed bioprosthetic valve is a growing trend for high-risk patients. The non-compliant stent of the previous prosthesis may prevent full expansion of the TAV, which has been shown to distort the leaflet configuration, and has been hypothesized to adversely affect durability. In this study, TAV leaflet fatigue damage under cyclic pressurization in the setting of stent underexpansion by 0 (fully expanded), 1, 2 and 3 mm was simulated using finite element analysis to test this hypothesis. In the 2 and 3 mm underexpanded devices, the TAV leaflets exhibited severe pin-wheeling during valve closure, which increased leaflet stresses dramatically, and resulted in accelerated fatigue damage of the leaflets. The leaflet fatigue damage in the 1 mm underexpanded case was similar to that in the fully expanded case. Clinically a range of 10-15% underexpansion is generally considered acceptable; however, it was observed in this study that ≥2 mm (≥9.1%) underexpansion, will significantly impact device durability. Further study is necessary to determine the impact of various deployment conditions, i.e. non-uniform and non-circular deployments and different implantation heights, on differing TAV devices, but it is clear that the normal TAV leaflet configuration must be preserved in order to preserve durability.

Entities:  

Keywords:  Finite element analysis; Soft tissue fatigue damage; Stent underexpansion; Transcatheter aortic valve; Valve-in-valve

Mesh:

Year:  2016        PMID: 27734178      PMCID: PMC5300953          DOI: 10.1007/s10439-016-1738-8

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  44 in total

Review 1.  Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves.

Authors:  Ronen Gurvitch; Anson Cheung; Jian Ye; David A Wood; Alexander B Willson; Stefan Toggweiler; Ronald Binder; John G Webb
Journal:  J Am Coll Cardiol       Date:  2011-11-15       Impact factor: 24.094

2.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.

Authors:  Wei Sun; Kewei Li; Eric Sirois
Journal:  J Biomech       Date:  2010-12-01       Impact factor: 2.712

3.  Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.

Authors:  A N Smuts; D C Blaine; C Scheffer; H Weich; A F Doubell; K H Dellimore
Journal:  J Mech Behav Biomed Mater       Date:  2010-09-29

4.  Carpentier-Edwards Perimount valves--morphological findings in surgical explants.

Authors:  Jagdish Butany; Vidhya Nair; Shaun W Leong; Gursharan S Soor; Chistopher Feindel
Journal:  J Card Surg       Date:  2007 Jan-Feb       Impact factor: 1.620

5.  Mechanisms, treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis.

Authors:  Antonio J Muñoz-García; Juan H Alonso-Briales; Manuel F Jiménez-Navarro; Juan Caballero-Borrego; Antonio J Domínguez-Franco; Isabel Rodríguez-Bailón; Miguel Such-Martínez; José M Hernández-García; Eduardo de Teresa-Galván
Journal:  Int J Cardiol       Date:  2011-04-05       Impact factor: 4.164

6.  3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.

Authors:  Alexander B Willson; John G Webb; Troy M Labounty; Stephan Achenbach; Robert Moss; Miriam Wheeler; Christopher Thompson; James K Min; Ronen Gurvitch; Bjarne L Norgaard; Cameron J Hague; Stefan Toggweiler; Ronald Binder; Melanie Freeman; Rohan Poulter; Steen Poulsen; David A Wood; Jonathon Leipsic
Journal:  J Am Coll Cardiol       Date:  2012-02-22       Impact factor: 24.094

7.  Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: A fatigue simulation study.

Authors:  Caitlin Martin; Wei Sun
Journal:  J Biomech       Date:  2015-08-07       Impact factor: 2.712

8.  Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving system.

Authors:  Alexander W Leber; Markus Kasel; Thomas Ischinger; Ulrich H Ebersberger; Diethmar Antoni; Martin Schmidt; Gotthard Riess; Vivian Renz; Armin Huber; Thomas Helmberger; Ellen Hoffmann
Journal:  Int J Cardiol       Date:  2011-12-22       Impact factor: 4.164

9.  Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties.

Authors:  Caitlin Martin; Wei Sun
Journal:  Biomech Model Mechanobiol       Date:  2013-10-04

10.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

Authors:  Danny Dvir; John G Webb; Sabine Bleiziffer; Miralem Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil E Moat; Massimo Napodano; Manuel Wilbring; Alfredo G Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre; Federico De Marco; Claudia Fiorina; Anna Sonia Petronio; Rui C Teles; Luca Testa; Jean-Claude Laborde; Martin B Leon; Ran Kornowski
Journal:  JAMA       Date:  2014-07       Impact factor: 56.272

View more
  7 in total

1.  The choice of heart valve prosthesis for aortic valve replacement in the young: about choices and consequences.

Authors:  Thierry Bove
Journal:  Ann Transl Med       Date:  2018-05

2.  Characterization of mechanical properties of pericardium tissue using planar biaxial tension and flexural deformation.

Authors:  Kyle Murdock; Caitlin Martin; Wei Sun
Journal:  J Mech Behav Biomed Mater       Date:  2017-09-13

Review 3.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

4.  Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

Authors:  Hoda Hatoum; Shelley Gooden; Megan Heitkemper; Kevin M Blum; Jason Zakko; Martin Bocks; Tai Yi; Yen-Lin Wu; Yadong Wang; Christopher K Breuer; Lakshmi Prasad Dasi
Journal:  Ann Biomed Eng       Date:  2020-02-12       Impact factor: 3.934

5.  Impact of Transcatheter Aortic Valve Size on Leaflet Stresses: Implications for Durability and Optimal Grey Zone Sizing.

Authors:  Yue Xuan; Danny Dvir; Andrew D Wisneski; Zhongjie Wang; Jian Ye; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  AsiaIntervention       Date:  2020-12

6.  Designing a Novel Asymmetric Transcatheter Aortic Valve for Stenotic Bicuspid Aortic Valves Using Patient-Specific Computational Modeling.

Authors:  Ryan T Helbock; Salwa B Anam; Brandon J Kovarovic; Marvin J Slepian; Ashraf Hamdan; Rami Haj-Ali; Danny Bluestein
Journal:  Ann Biomed Eng       Date:  2022-08-30       Impact factor: 4.219

7.  Automatic Identification of Bioprostheses on X-ray Angiographic Sequences of Transcatheter Aortic Valve Implantation Procedures Using Deep Learning.

Authors:  Laura Busto; César Veiga; José A González-Nóvoa; Marcos Loureiro-Ga; Víctor Jiménez; José Antonio Baz; Andrés Íñiguez
Journal:  Diagnostics (Basel)       Date:  2022-01-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.