Abstract

Percutaneous Aortic Valve (PAV) replacement is an attractive alternative to open heart surgery, especially for patients considered to be poor surgical candidates. Despite this, PAV replacement still has its limitations and associated risks. Bioprosthetic heart valves still have poor long-term durability due to calcification and mechanical failure. In addition, the implantation procedure often presents novel challenges, including damage to the expandable stents and bioprosthetic leaflets. In this study, a simplified version of Fung's elastic constitutive model for skin, developed by Sun and Sacks, was implemented using finite element analysis (FEA) and applied to the modelling of bovine and kangaroo pericardium. The FEA implementation was validated by simulating biaxial tests and by comparing the results with experimental data. Concepts for different PAV geometries were developed by incorporating valve design and performance parameters, along with stent constraints. The influence of effects such as different leaflet material, material orientation and abnormal valve dilation on the valve function was investigated. The stress distribution across the valve leaflet was also examined to determine the appropriate fibre direction for the leaflet. The simulated attachment forces were compared with suture tearing tests performed on the pericardium to evaluate suture density. It is concluded that kangaroo pericardium is suitable for PAV applications, and superior to bovine pericardium, due to its lower thickness and greater extensibility.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21094482     DOI: 10.1016/j.jmbbm.2010.09.009

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  11 in total

1.  Implementation and validation of constitutive relations for human dermis mechanical response.

Authors:  Alessandra Aldieri; Mara Terzini; Cristina Bignardi; Elisabetta M Zanetti; Alberto L Audenino
Journal:  Med Biol Eng Comput       Date:  2018-05-19       Impact factor: 2.602

2.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Authors:  Caitlin Martin; Wei Sun
Journal:  Ann Biomed Eng       Date:  2016-10-12       Impact factor: 3.934

3.  Bovine Pericardium of High Fibre Dispersion Has High Fatigue Life and Increased Collagen Content; Potentially an Untapped Source of Heart Valve Leaflet Tissue.

Authors:  Alix Whelan; Elizabeth Williams; David R Nolan; Bruce Murphy; Paul S Gunning; David O'Reilly; Caitríona Lally
Journal:  Ann Biomed Eng       Date:  2020-10-15       Impact factor: 3.934

Review 4.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

5.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment.

Authors:  Qian Wang; Eric Sirois; Wei Sun
Journal:  J Biomech       Date:  2012-06-13       Impact factor: 2.712

6.  Evidence of adaptive mitral leaflet growth.

Authors:  Manuel K Rausch; Frederick A Tibayan; D Craig Miller; Ellen Kuhl
Journal:  J Mech Behav Biomed Mater       Date:  2012-07-10

7.  Biaxial tension of fibrous tissue: using finite element methods to address experimental challenges arising from boundary conditions and anisotropy.

Authors:  Nathan T Jacobs; Daniel H Cortes; Edward J Vresilovic; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

8.  Power type strain energy function model and prediction of the anisotropic mechanical properties of skin using uniaxial extension data.

Authors:  Lin Li; Xiuqing Qian; Hui Wang; Lin Hua; Haixia Zhang; Zhicheng Liu
Journal:  Med Biol Eng Comput       Date:  2013-07-18       Impact factor: 2.602

9.  Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.

Authors:  Paul S Gunning; Neelakantan Saikrishnan; Ajit P Yoganathan; Laoise M McNamara
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

10.  A Proof of Concept Study of Using Machine-Learning in Artificial Aortic Valve Design: From Leaflet Design to Stress Analysis.

Authors:  Liang Liang; Bill Sun
Journal:  Bioengineering (Basel)       Date:  2019-11-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.