Literature DB >> 32052320

Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

Hoda Hatoum1, Shelley Gooden1, Megan Heitkemper2, Kevin M Blum2, Jason Zakko2, Martin Bocks3, Tai Yi2, Yen-Lin Wu4, Yadong Wang4, Christopher K Breuer2, Lakshmi Prasad Dasi5.   

Abstract

The scarcity of data available on the best approach for pulmonary fetal valve replacement or implantation necessitate an investigation on whether practices using adult transcatheter valves could be translated to fetal applications. The objective of this study is to evaluate the hemodynamic characteristics and the turbulent properties of a fetal sized trileaflet transcatheter pulmonary valve in comparison with an adult balloon-expandable valve in order to assess the possibility of designing valves for fetal applications using dynamic similarity. A 6 mm fetal trileaflet valve and a 26 mm SAPIEN 3 valve were assessed in a pulse duplicator. Particle image velocimetry was performed. Pressure gradient (ΔP), effective orifice area (EOA), regurgitant fractions (RF), pinwheeling indices (PI) and turbulent stresses were evaluated. ΔP was 8.56 ± 0.139 and 7.76 ± 0.083 mmHg with fetal valve and SAPIEN respectively (p < 0.0001); EOA was 0.10 ± 0.0007 and 2.1 ± 0.025 cm2 with fetal valve and SAPIEN respectively (p < 0.0001); RF with the fetal valve was 2.35 ± 1.99% and with SAPIEN 10.92 ± 0.11% (p < 0.0001); PI with fetal valve was 0.404 ± 0.01 and with SAPIEN 0.37 ± 0.07; The flow regime with the fetal valve was turbulent and Reynolds numbers reached about 7000 while those with the SAPIEN reached about 20,000 at peak velocity. Turbulent stresses were significantly higher with fetal valve compared with SAPIEN. Instantaneous viscous shear stresses with fetal valve were 5.8 times higher than those obtained with SAPIEN and Reynolds shear stresses were 2.5 times higher during peak systole. The fetal valve implantation leads to a turbulent flow (specific to this particular type and design of valve) regime unlike what is expected of a small valve with different flow properties compared to adult valves.

Entities:  

Keywords:  Balloon-expandable valve; Blood damage; Dynamic similarity; Fetal valve; Hemodynamics; Transcatheter aortic valve replacement

Mesh:

Substances:

Year:  2020        PMID: 32052320      PMCID: PMC7286783          DOI: 10.1007/s10439-020-02475-3

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  40 in total

1.  Rethinking turbulence in blood.

Authors:  Luca Antiga; David A Steinman
Journal:  Biorheology       Date:  2009       Impact factor: 1.875

2.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Authors:  Caitlin Martin; Wei Sun
Journal:  Ann Biomed Eng       Date:  2016-10-12       Impact factor: 3.934

3.  Estimation of shear stress-related blood damage in heart valve prostheses--in vitro comparison of 25 aortic valves.

Authors:  M Giersiepen; L J Wurzinger; R Opitz; H Reul
Journal:  Int J Artif Organs       Date:  1990-05       Impact factor: 1.595

4.  Fetal cardiac output estimated by Doppler echocardiography during mid- and late gestation.

Authors:  M C De Smedt; G H Visser; E J Meijboom
Journal:  Am J Cardiol       Date:  1987-08-01       Impact factor: 2.778

Review 5.  Flow-induced trauma to blood cells.

Authors:  S P Sutera
Journal:  Circ Res       Date:  1977-07       Impact factor: 17.367

6.  Stented valve dynamic behavior induced by polyester fiber leaflet material in transcatheter aortic valve devices.

Authors:  Hoda Hatoum; Frederick Heim; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2018-06-28

7.  Impact of patient-specific morphologies on sinus flow stasis in transcatheter aortic valve replacement: An in vitro study.

Authors:  Hoda Hatoum; Jennifer Dollery; Scott M Lilly; Juan Crestanello; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-07       Impact factor: 5.209

8.  Fetal aortic and pulmonary artery diameters: sonographic measurements in growth-retarded fetuses.

Authors:  M S Cartier; P M Doubilet
Journal:  AJR Am J Roentgenol       Date:  1988-11       Impact factor: 3.959

Review 9.  Fluid mechanics of artificial heart valves.

Authors:  Lakshmi P Dasi; Helene A Simon; Philippe Sucosky; Ajit P Yoganathan
Journal:  Clin Exp Pharmacol Physiol       Date:  2009-02       Impact factor: 2.557

10.  An in vitro evaluation of turbulence after transcatheter aortic valve implantation.

Authors:  Hoda Hatoum; Atieh Yousefi; Scott Lilly; Pablo Maureira; Juan Crestanello; Lakshmi P Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-02       Impact factor: 5.209

View more
  1 in total

1.  Flow dynamics of surgical and transcatheter aortic valves: Past to present.

Authors:  Hoda Hatoum; Sunyoung Ahn; Scott Lilly; Pablo Maureira; Juan Crestanello; Vinod H Thourani; Lakshmi Prasad Dasi
Journal:  JTCVS Open       Date:  2022-01-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.