Literature DB >> 27655141

How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review.

Eduard J De Valk1, Julia C A Noorduyn2, Eduard L A R Mutsaerts2.   

Abstract

PURPOSE: One of the most important factors leading to revision of total knee arthroplasties (TKA) is malrotation of femoral and/or tibial component. Rotation measurements performed on radiographs are limited and less reliable compared to 2D computed tomography (CT). Nowadays, 2D-CT and 3D-CT can be distinguished in measuring rotation of the TKA components. The aim of this systematic review is to determine the most reliable CT techniques in measuring rotation of the TKA components and to investigate possible cut-off points that can be used in the clinician's decision for a possible revision of the TKA.
METHODS: A search of PubMed, Embase, the Cochrane Central Register of Controlled Trials and Web of Science was performed up to April 2015. Final selections of 12 articles were used in this systematic review.
RESULTS: 3D-CT, compared to 2D-CT, is more reliable and shows a high level of intra- and interobserver reliability. Femoral component rotation is measured using the component's posterior condylar line or inner pegs in relation to the epicondylar axis. Five different techniques were used to measure tibial component rotation. The posterior border of the tibial component in relationship to the geometric centre and tibial tubercle was most frequently used.
CONCLUSION: This systematic review shows a strong preference for 3D-CT to determine the component's rotation following a TKA. The literature shows consensus on the reference points of the femoral component. In measurements of the tibial component, various techniques are used with similar results. No clear cut-off point for revision of malrotated TKA components can be stated because of limited evidence. LEVEL OF EVIDENCE: III.

Entities:  

Keywords:  CT; Component rotation; Computed tomography; Malrotation; Post-operative measurements; Total knee arthroplasty

Mesh:

Year:  2016        PMID: 27655141     DOI: 10.1007/s00167-016-4325-5

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  32 in total

1.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

2.  Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty.

Authors:  Kouichi Kanekasu; Makoto Kondo; Yoshinori Kadoya
Journal:  Clin Orthop Relat Res       Date:  2005-05       Impact factor: 4.176

3.  Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation.

Authors:  J Lützner; F Krummenauer; C Wolf; K-P Günther; S Kirschner
Journal:  J Bone Joint Surg Br       Date:  2008-08

4.  Analysis of tibial component rotation following total knee arthroplasty using 3D high definition computed tomography.

Authors:  Glade E Roper; Adam D Bloemke; Catherine C Roberts; Mark J Spangehl; Henry D Clarke
Journal:  J Arthroplasty       Date:  2013-07-29       Impact factor: 4.757

5.  Internal rotation of the tibial component is frequent in stiff total knee arthroplasty.

Authors:  Martin Bédard; Kelly G Vince; John Redfern; Stacy R Collen
Journal:  Clin Orthop Relat Res       Date:  2011-04-30       Impact factor: 4.176

6.  Femoral and tibial torsion measurements with 3D models based on low-dose biplanar radiographs in comparison with standard CT measurements.

Authors:  Florian M Buck; Roman Guggenberger; Peter P Koch; Christian W A Pfirrmann
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

7.  Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients.

Authors:  C E H Scott; C R Howie; D MacDonald; L C Biant
Journal:  J Bone Joint Surg Br       Date:  2010-09

8.  Inter- and intraobserver reliability of two-dimensional CT scan for total knee arthroplasty component malrotation.

Authors:  Beau Konigsberg; Ryan Hess; Curtis Hartman; Lynette Smith; Kevin L Garvin
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

9.  Malrotation causing patellofemoral complications after total knee arthroplasty.

Authors:  R A Berger; L S Crossett; J J Jacobs; H E Rubash
Journal:  Clin Orthop Relat Res       Date:  1998-11       Impact factor: 4.176

Review 10.  Effect of rotational alignment on outcome of total knee arthroplasty.

Authors:  Kars P Valkering; Stefan J Breugem; Michel Pj van den Bekerom; Willem E Tuinebreijer; Rutger C I van Geenen
Journal:  Acta Orthop       Date:  2015-02-24       Impact factor: 3.717

View more
  14 in total

1.  No influence of femoral component rotation by the lateral femoral posterior condylar cartilage remnant technique on clinical outcomes in navigation-assisted TKA.

Authors:  Seong Hwan Kim; Yong-Beom Park; Dae Woong Ham; Jae-Sung Lee; Min-Ku Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-02       Impact factor: 4.342

2.  The role of cone beam CT in the study of symptomatic total knee arthroplasty (TKA): a 20 cases report.

Authors:  Cosimo Nardi; Roberto Buzzi; Roberto Molteni; Carlo Cossi; Chiara Lorini; Linda Calistri; Stefano Colagrande
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

3.  Radiographic Evaluation of Alignment Following Total Knee Arthroplasty - a Systematic Review. Part II.

Authors:  Bogdan Stefan Cretu; Calin Dragosloveanu; Serban Dragosloveanu; Stefan Cristea
Journal:  Maedica (Buchar)       Date:  2018-06

4.  Analysis of in-vivo articular cartilage contact surface of the knee during a step-up motion.

Authors:  Peng Yin; Jing-Sheng Li; Willem A Kernkamp; Tsung-Yuan Tsai; Seung-Hoon Baek; Ali Hosseini; Lin Lin; Peifu Tang; Guoan Li
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-09-08       Impact factor: 2.063

5.  Do modern total knee replacements improve tibial coverage?

Authors:  Malin Meier; Jonathan Webb; Jamie E Collins; Johannes Beckmann; Wolfgang Fitz
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-01-25       Impact factor: 4.342

6.  [Accuracy of patellar tendon at the attachment as anatomic landmark for rotational alignment of tibial component].

Authors:  Leshu Zhang; Jincheng Zhang; Hang Zhou; Wang Chen; Zhenghao Hu; Xiangyang Chen; Shuo Feng
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-06-15

Review 7.  Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review.

Authors:  Alfredo Schiavone Panni; Francesco Ascione; Marco Rossini; Adriano Braile; Katia Corona; Michele Vasso; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-12-15       Impact factor: 4.342

8.  Three dimensional gait analysis in patients with symptomatic component mal-rotation after total knee arthroplasty.

Authors:  Michael W Maier; Stefan Aschauer; Sebastian I Wolf; Thomas Dreher; Christian Merle; Rudi G Bitsch
Journal:  Int Orthop       Date:  2018-09-10       Impact factor: 3.075

9.  A novel technology for 3D knee prosthesis planning and treatment evaluation using 2D X-ray radiographs: a clinical evaluation.

Authors:  Guoyan Zheng; Hagen Hommel; Alper Akcoltekin; Benedikt Thelen; Jan Stifter; Geert Peersman
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-21       Impact factor: 2.924

10.  A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images.

Authors:  Emma L Robertson; Martin Hengherr; Felix Amsler; Michael T Hirschmann; Dominic T Mathis
Journal:  Skeletal Radiol       Date:  2021-01-04       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.