Literature DB >> 23906867

Analysis of tibial component rotation following total knee arthroplasty using 3D high definition computed tomography.

Glade E Roper1, Adam D Bloemke, Catherine C Roberts, Mark J Spangehl, Henry D Clarke.   

Abstract

Malrotation of the tibial component is associated with poor outcomes after total knee arthroplasty, yet the definition and evaluation of this problem remain controversial. Contributing factors to this controversy include inconsistent and cumbersome methods for measuring rotation, based upon transposed measurements from multiple computed tomography images. We developed and tested the reliability of a new, simple method for measuring tibial component rotation based upon a single, three-dimensional high definition, axial computed tomography image. Sixty individual knees after total knee arthroplasty were evaluated. The intra-reliability and inter-reliability both exceeded 0.9 whether the tibial component was made of titanium, cobalt-chrome or all-polyethylene. Based upon these findings we suggest that this technique be used for evaluating tibial component rotation in future studies.
© 2013.

Entities:  

Keywords:  computed tomography; rotational mal-alignment; tibial anatomy; total knee arthroplasty

Mesh:

Substances:

Year:  2013        PMID: 23906867     DOI: 10.1016/j.arth.2013.04.053

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  The role of cone beam CT in the study of symptomatic total knee arthroplasty (TKA): a 20 cases report.

Authors:  Cosimo Nardi; Roberto Buzzi; Roberto Molteni; Carlo Cossi; Chiara Lorini; Linda Calistri; Stefano Colagrande
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

Review 2.  Imaging update in arthroplasty.

Authors:  Nicholas Ong; Izwan Zailan; Ankit Tandon
Journal:  J Clin Orthop Trauma       Date:  2021-10-21

Review 3.  How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review.

Authors:  Eduard J De Valk; Julia C A Noorduyn; Eduard L A R Mutsaerts
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-21       Impact factor: 4.342

Review 4.  Effect of rotational alignment on outcome of total knee arthroplasty.

Authors:  Kars P Valkering; Stefan J Breugem; Michel Pj van den Bekerom; Willem E Tuinebreijer; Rutger C I van Geenen
Journal:  Acta Orthop       Date:  2015-02-24       Impact factor: 3.717

5.  The personalized Berger method is usable to solve the problem of tibial rotation.

Authors:  Gömöri András; Gábor Németh; Csaba Zsolt Oláh; Gábor Lénárt; Zsanett Drén; Miklós Papp
Journal:  J Exp Orthop       Date:  2021-12-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.