Literature DB >> 23813180

Inter- and intraobserver reliability of two-dimensional CT scan for total knee arthroplasty component malrotation.

Beau Konigsberg1, Ryan Hess, Curtis Hartman, Lynette Smith, Kevin L Garvin.   

Abstract

BACKGROUND: Rotational malalignment of total knee arthroplasty (TKA) has been correlated with patellofemoral maltracking, knee instability, and stiffness. CT is the most accurate method to assess rotational alignment of prosthetic components after TKA, but inter- and intraobserver reliability of CT scans for this use has not been well documented. QUESTIONS/PURPOSES: The objective of this study was to determine the inter- and intraobserver reliability and the repeatability of the measurement of TKA component rotation using two-dimensional CT scans.
METHODS: Fifty-two CT scans of TKAs being evaluated for revision surgery were measured by three different physicians. An orthopaedic resident and attending measured the same scans twice (more than 2 weeks apart) and a musculoskeletal radiologist measured them once. To assess interobserver reliability, intraclass correlation coefficients (ICCs) with two-way mixed-effects analysis of variance models as well as 95% confidence intervals for each were done. The repeatability coefficient was calculated as well, which is defined as the difference in measurements that include 95% of the values. This indicates the magnitude of variability among measurements in the same scale, which in this study is degrees.
RESULTS: The interobserver ICC measurement for the femoral component was 0.386 (poor), and it was 0.670 (good) for the tibial component. The interobserver ICC for the combined rotation measurements was 0.617 (good). The intraobserver ICC for the femoral component was 0.606 (good), and it was 0.809 (very good) for the tibial component. The intraobserver ICC for combined rotation was 0.751 (good). The intraobserver repeatability coefficient for the femoral component was 0.49°, 10.64° for the tibial component, and 12.29° for combined rotation.
CONCLUSIONS: In this study, the inter- and intraobserver reliability, and the repeatability, of TKA component rotation were variable. This raises concern about whether CT scan is diagnostic in the assessment of component malrotation after TKA.

Entities:  

Mesh:

Year:  2014        PMID: 23813180      PMCID: PMC3889411          DOI: 10.1007/s11999-013-3111-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  20 in total

1.  Rotational instability and malrotation after total knee arthroplasty.

Authors:  R A Berger; H E Rubash
Journal:  Orthop Clin North Am       Date:  2001-10       Impact factor: 2.472

2.  Anterior knee pain due to biplanar rotatory malalignment of the femoral component in total knee arthroplasty. Case report.

Authors:  Roger Torga-Spak; Shital N Parikh; Steven A Stuchin
Journal:  J Knee Surg       Date:  2004-04       Impact factor: 2.757

3.  Internal rotation of the tibial component is frequent in stiff total knee arthroplasty.

Authors:  Martin Bédard; Kelly G Vince; John Redfern; Stacy R Collen
Journal:  Clin Orthop Relat Res       Date:  2011-04-30       Impact factor: 4.176

4.  The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction.

Authors:  M T Hirschmann; P Konala; F Amsler; F Iranpour; N F Friederich; J P Cobb
Journal:  J Bone Joint Surg Br       Date:  2011-05

5.  Component rotation and anterior knee pain after total knee arthroplasty.

Authors:  R L Barrack; T Schrader; A J Bertot; M W Wolfe; L Myers
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

6.  The total condylar prosthesis.

Authors:  J N Insall; M Kelly
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

7.  The patellofemoral joint in total condylar knee arthroplasty. Pros and cons based on five- to ten-year follow-up observations.

Authors:  C S Ranawat
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Total knee dislocation due to rotatory malalignment of tibial component: a case report.

Authors:  J H Bargren
Journal:  Clin Orthop Relat Res       Date:  1980 Mar-Apr       Impact factor: 4.176

10.  Revision of the stiff total knee arthroplasty.

Authors:  Christian P Christensen; John J Crawford; Matthew D Olin; Thomas Parker Vail
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

View more
  27 in total

1.  No influence of femoral component rotation by the lateral femoral posterior condylar cartilage remnant technique on clinical outcomes in navigation-assisted TKA.

Authors:  Seong Hwan Kim; Yong-Beom Park; Dae Woong Ham; Jae-Sung Lee; Min-Ku Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-02       Impact factor: 4.342

2.  Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review.

Authors:  Paweł Skowronek; Markus Arnold; Christian Starke; Agnieszka Bartyzel; Lukas B Moser; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-30       Impact factor: 4.342

3.  Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.

Authors:  Tsan-Wen Huang; Kuo-Ti Peng; Kuo-Chin Huang; Mel S Lee; Robert Wen-Wei Hsu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-21       Impact factor: 4.342

4.  The role of cone beam CT in the study of symptomatic total knee arthroplasty (TKA): a 20 cases report.

Authors:  Cosimo Nardi; Roberto Buzzi; Roberto Molteni; Carlo Cossi; Chiara Lorini; Linda Calistri; Stefano Colagrande
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

5.  Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

Authors:  José Figueroa; Juan Pablo Guarachi; José Matas; Magnus Arnander; Mario Orrego
Journal:  Int Orthop       Date:  2015-07-25       Impact factor: 3.075

6.  Tibiofemoral rotational alignment affects flexion angles in navigated posterior-stabilized total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Akihiko Toda; Shinya Oka; Kazuki Kodato; Koji Takayama; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

Review 7.  How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review.

Authors:  Eduard J De Valk; Julia C A Noorduyn; Eduard L A R Mutsaerts
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-21       Impact factor: 4.342

8.  Painful knee arthroplasty: current practice.

Authors:  Umberto Cottino; Federica Rosso; Antonio Pastrone; Federico Dettoni; Roberto Rossi; Matteo Bruzzone
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

9.  Comparison of custom to standard TKA instrumentation with computed tomography.

Authors:  Vincent Y Ng; Lindsay Arnott; Jia Li; Ronald Hopkins; Jamie Lewis; Sean Sutphen; Lisa Nicholson; Douglas Reader; Michael A McShane
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-25       Impact factor: 4.342

10.  A CT-based radiomics nomogram for prediction of human epidermal growth factor receptor 2 status in patients with gastric cancer.

Authors:  Yexing Li; Zixuan Cheng; Olivier Gevaert; Lan He; Yanqi Huang; Xin Chen; Xiaomei Huang; Xiaomei Wu; Wen Zhang; Mengyi Dong; Jia Huang; Yucun Huang; Ting Xia; Changhong Liang; Zaiyi Liu
Journal:  Chin J Cancer Res       Date:  2020-02       Impact factor: 5.087

View more