Literature DB >> 27653673

Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury.

Hee J Park1, So Y Lee1, Seon H Choi1, Jin H Ahn2, Se J Park2, Jai H Park2, Eugene Kim2.   

Abstract

OBJECTIVE: To compare image quality between three-dimensional volume isotropic turbo spin echo acquisition (3D VISTA) with the posterior cruciate ligament (PCL) view and two-dimensional (2D) fast spin echo (FSE) for evaluation of PCL injury.
METHODS: This retrospective study included 60 patients with clinical suspicion of PCL injury who underwent both 2D FSE and 3D VISTA of the knee between January 2015 and December 2015. The diagnostic performance of each oblique coronal view and the combined images was evaluated for sensitivity, specificity and accuracy for diagnosing a PCL tear. The arthroscopically confirmed diagnoses were used as the reference standard. Data were analyzed using the McNemar test.
RESULTS: The mean contrast-to-noise ratio was significantly higher for 3D VISTA than for 2D FSE. The two imaging modalities did not differ significantly in anatomical identification ability, with the exception of margin sharpness, which was inferior for 3D VISTA with Reader 2 (p = 0.038). When we classified the diagnoses of PCL injury as normal or abnormal, there were no significant differences in sensitivity, specificity or accuracy between the PCL view of 3D VISTA and 2D FSE images (p > 0.05).
CONCLUSION: 3D VISTA had a superior contrast-to-noise ratio than 2D FSE and similar image quality in the evaluation of the PCL. The PCL view of 3D VISTA has the same diagnostic ability as 2D FSE in the diagnosis of PCL injury and can thus replace 2D FSE. Advances in knowledge: The oblique coronal view 3D VISTA MRI has similar diagnostic ability to 2D FSE in the diagnosis of PCL injury, and therefore 3D VISTA image can replace 2D FSE.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27653673      PMCID: PMC5124851          DOI: 10.1259/bjr.20160554

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.

Authors:  Jung Min Seo; Young Cheol Yoon; Jong Won Kwon
Journal:  Acta Radiol       Date:  2011-12-01       Impact factor: 1.990

2.  Three-dimensional isotropic T2-weighted cervical MRI at 3T: comparison with two-dimensional T2-weighted sequences.

Authors:  J W Kwon; Y C Yoon; S-H Choi
Journal:  Clin Radiol       Date:  2011-12-03       Impact factor: 2.350

3.  Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Y Park; So-Yeon Lee; Yang-Soo Kim
Journal:  Skeletal Radiol       Date:  2012-02-10       Impact factor: 2.199

4.  Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury.

Authors:  H J Park; S Y Lee; N H Park; M H Rho; E C Chung; J H Park; S J Park
Journal:  Clin Radiol       Date:  2016-01-14       Impact factor: 2.350

5.  Understanding interobserver agreement: the kappa statistic.

Authors:  Anthony J Viera; Joanne M Garrett
Journal:  Fam Med       Date:  2005-05       Impact factor: 1.756

6.  Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee--image quality and diagnostic performance.

Authors:  Oliver Ristow; Lynne Steinbach; Gregory Sabo; Roland Krug; Markus Huber; Isabel Rauscher; Ben Ma; Thomas M Link
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

7.  MRI of the knee ligaments and menisci: comparison of isotropic-resolution 3D and conventional 2D fast spin-echo sequences at 3 T.

Authors:  Naveen Subhas; Amy Kao; Maxime Freire; Joshua M Polster; Nancy A Obuchowski; Carl S Winalski
Journal:  AJR Am J Roentgenol       Date:  2011-08       Impact factor: 3.959

8.  Clinical value of fat-suppressed 3D volume isotropic spin-echo (VISTA) sequence compared to 2D sequence in evaluating internal structures of the knee.

Authors:  Daekeon Lim; Young Han Lee; Sungjun Kim; Ho-Taek Song; Jin-Suck Suh
Journal:  Acta Radiol       Date:  2015-01-13       Impact factor: 1.990

9.  Arthroscopic examination of the posterior cruciate ligament.

Authors:  J Lysholm; J Gillquist
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

10.  Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.

Authors:  R M Patten; M L Richardson; G Zink-Brody; B A Rolfe
Journal:  J Comput Assist Tomogr       Date:  1994 Sep-Oct       Impact factor: 1.826

View more
  2 in total

1.  Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist.

Authors:  Hee Jin Park; So Yeon Lee; Kyung A Kang; Eun Young Kim; Hun Kyu Shin; Se Jin Park; Jai Hyung Park; Eugene Kim
Journal:  Br J Radiol       Date:  2018-01-05       Impact factor: 3.039

2.  Diagnostic Performance of MRI for Assessing Parametrial Invasion in Cervical Cancer: A Head-to-Head Comparison between Oblique and True Axial T2-Weighted Images.

Authors:  Sungmin Woo; Min Hoan Moon; Jeong Yeon Cho; Seung Hyup Kim; Sang Youn Kim
Journal:  Korean J Radiol       Date:  2019-03       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.