Literature DB >> 19137309

Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee--image quality and diagnostic performance.

Oliver Ristow1, Lynne Steinbach, Gregory Sabo, Roland Krug, Markus Huber, Isabel Rauscher, Ben Ma, Thomas M Link.   

Abstract

The objective of this study was to compare a newly developed fat-saturated intermediate-weighted (IM-w) 3D fast spin-echo (FSE) sequence with standard 2D IM-w FSE sequences regarding image quality and diagnostic performance in assessing abnormal findings of the knee. MR imaging was performed at 3.0 T in 50 patients. Images were assessed independently by three radiologists. Image quality was rated significantly higher (p < 0.05) for the 2D versus the 3D FSE sequences. Sensitivity for cartilage lesions was slightly higher for the 3D sequence, but specificity was lower. Low contrast objects were better visualized with 2D sequences, while high contrast objects were better shown with the 3D sequence. Confidence scores were higher for 2D than for 3D sequences, but differences were not significant. In conclusion, isotropic 3D FSE IM-w imaging may enhance standard knee MRI by increased visualization of high contrast lesions; however, 3D FSE image quality was lower.

Entities:  

Mesh:

Year:  2009        PMID: 19137309     DOI: 10.1007/s00330-008-1260-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

Review 1.  Overview of MR imaging pulse sequences.

Authors:  J P Mugler
Journal:  Magn Reson Imaging Clin N Am       Date:  1999-11       Impact factor: 2.266

2.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

3.  Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques.

Authors:  Aaron Sodickson; Koenraad J Mortele; Matthew A Barish; Kelly H Zou; Steven Thibodeau; Clare M C Tempany
Journal:  Radiology       Date:  2006-02       Impact factor: 11.105

4.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

5.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

6.  Diagnosis of articular cartilage abnormalities of the knee: prospective clinical evaluation of a 3D water-excitation true FISP sequence.

Authors:  Sylvain R Duc; Peter Koch; Marius R Schmid; Wilhelm Horger; Juerg Hodler; Christian W A Pfirrmann
Journal:  Radiology       Date:  2007-03-30       Impact factor: 11.105

Review 7.  MRI of articular cartilage in OA: novel pulse sequences and compositional/functional markers.

Authors:  Garry E Gold; Deborah Burstein; Bernard Dardzinski; Phillip Lang; Fernando Boada; Timothy Mosher
Journal:  Osteoarthritis Cartilage       Date:  2006-05-23       Impact factor: 6.576

8.  Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: comparison with a conventional spin-echo sequence.

Authors:  E M Escobedo; J C Hunter; G C Zink-Brody; A J Wilson; S D Harrison; D J Fisher
Journal:  AJR Am J Roentgenol       Date:  1996-11       Impact factor: 3.959

Review 9.  Cartilage imaging: motivation, techniques, current and future significance.

Authors:  Thomas M Link; Robert Stahl; Klaus Woertler
Journal:  Eur Radiol       Date:  2006-11-09       Impact factor: 5.315

10.  MRI of patellar articular cartilage: evaluation of an optimized gradient echo sequence (3D-DESS).

Authors:  S Ruehm; M Zanetti; J Romero; J Hodler
Journal:  J Magn Reson Imaging       Date:  1998 Nov-Dec       Impact factor: 4.813

View more
  28 in total

1.  Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.

Authors:  Jacob C Mandell; Jeffrey A Rhodes; Nehal Shah; Glenn C Gaviola; Andreas H Gomoll; Stacy E Smith
Journal:  Skeletal Radiol       Date:  2017-07-17       Impact factor: 2.199

2.  Optimizing isotropic three-dimensional fast spin-echo methods for imaging the knee.

Authors:  Charles Q Li; Weitian Chen; Jarrett K Rosenberg; Philip J Beatty; Richard Kijowski; Brian A Hargreaves; Reed F Busse; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2014-06       Impact factor: 4.813

3.  [Morphological and functional cartilage imaging].

Authors:  C Rehnitz; M-A Weber
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

4.  CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons.

Authors:  Vivek Kalia; Benjamin Fritz; Rory Johnson; Wesley D Gilson; Esther Raithel; Jan Fritz
Journal:  Eur Radiol       Date:  2017-01-23       Impact factor: 5.315

5.  Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.

Authors:  Faysal F Altahawi; Kevin J Blount; Nicholas P Morley; Esther Raithel; Imran M Omar
Journal:  Skeletal Radiol       Date:  2016-10-15       Impact factor: 2.199

6.  Can a single isotropic 3D fast spin echo sequence replace three-plane standard proton density fat-saturated knee MRI at 1.5 T?

Authors:  B Pass; P Robinson; R Hodgson; A J Grainger
Journal:  Br J Radiol       Date:  2015-06-12       Impact factor: 3.039

7.  SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Yong Park; So-Yeon Lee; Yang-Soo Kim
Journal:  Eur Radiol       Date:  2012-08-04       Impact factor: 5.315

8.  [Morphological and functional cartilage imaging].

Authors:  C Rehnitz; M-A Weber
Journal:  Radiologe       Date:  2014-06       Impact factor: 0.635

9.  3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times.

Authors:  Osamah M Abdulaal; Louise Rainford; Peter MacMahon; Eoin Kavanagh; Marie Galligan; James Cashman; Allison McGee
Journal:  Eur Radiol       Date:  2017-04-21       Impact factor: 5.315

Review 10.  [Advanced cartilage imaging for detection of cartilage injuries and osteochondral lesions].

Authors:  A S Gersing; B J Schwaiger; K Wörtler; P M Jungmann
Journal:  Radiologe       Date:  2018-05       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.