Literature DB >> 27435230

Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics.

Emilie Bollache1, Pim van Ooij2, Alex Powell2, James Carr2, Michael Markl2,3, Alex J Barker2.   

Abstract

The purpose of this study was to compare aortic flow and velocity quantification using 4D flow MRI and 2D CINE phase-contrast (PC)-MRI with either one-directional (2D-1dir) or three-directional (2D-3dir) velocity encoding. 15 healthy volunteers (51 ± 19 years) underwent MRI including (1) breath-holding 2D-1dir and (2) free breathing 2D-3dir PC-MRI in planes orthogonal to the ascending (AA) and descending (DA) aorta, as well as (3) free breathing 4D flow MRI with full thoracic aorta coverage. Flow quantification included the co-registration of the 2D PC acquisition planes with 4D flow MRI data, AA and DA segmentation, and calculation of AA and DA peak systolic velocity, peak flow and net flow volume for all sequences. Additionally, the 2D-3dir velocity taking into account the through-plane component only was used to obtain results analogous to a free breathing 2D-1dir acquisition. Good agreement was found between 4D flow and 2D-3dir peak velocity (differences = -3 to 6 %), peak flow (-7 %) and net volume (-14 to -9 %). In contrast, breath-holding 2D-1dir measurements exhibited indices significantly lower than free breathing 2D-3dir and 2D-1dir (differences = -35 to -7 %, p < 0.05). Finally, high correlations (r ≥ 0.97) were obtained for indices estimated with or without eddy current correction, with the lowest correlation observed for net volume. 4D flow and 2D-3dir aortic hemodynamic indices were in concordance. However, differences between respiration state and 2D-1dir and 2D-3dir measurements indicate that reference values should be established according to the PC-MRI sequence, especially for the widely used net flow (e.g. stroke volume in the AA).

Entities:  

Keywords:  4D flow MRI; Aortic hemodynamics; MRI; Phase-contrast

Mesh:

Year:  2016        PMID: 27435230      PMCID: PMC5096729          DOI: 10.1007/s10554-016-0938-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  38 in total

Review 1.  Hemodynamics in the cardiac catheterization laboratory of the 21st century.

Authors:  Rick A Nishimura; Blase A Carabello
Journal:  Circulation       Date:  2012-05-01       Impact factor: 29.690

2.  Cardiac index after acute ST-segment elevation myocardial infarction measured with phase-contrast cardiac magnetic resonance imaging.

Authors:  Gert Klug; Sebastian Johannes Reinstadler; Hans-Josef Feistritzer; Christian Kremser; Johannes P Schwaiger; Martin Reindl; Johannes Mair; Silvana Müller; Agnes Mayr; Wolfgang-Michael Franz; Bernhard Metzler
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

3.  Correction of phase offset errors in main pulmonary artery flow quantification.

Authors:  Jan-Willem Lankhaar; Mark B M Hofman; J Tim Marcus; Jaco J M Zwanenburg; Theo J C Faes; Anton Vonk-Noordegraaf
Journal:  J Magn Reson Imaging       Date:  2005-07       Impact factor: 4.813

4.  Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow.

Authors:  Sarah Nordmeyer; Eugénie Riesenkampff; Daniel Messroghli; Siegfried Kropf; Johannes Nordmeyer; Felix Berger; Titus Kuehne
Journal:  J Magn Reson Imaging       Date:  2012-09-13       Impact factor: 4.813

5.  Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging.

Authors:  Kate Hanneman; Milani Sivagnanam; Elsie T Nguyen; Rachel Wald; Andreas Greiser; Andrew M Crean; Sebastian Ley; Bernd J Wintersperger
Journal:  Acad Radiol       Date:  2014-08       Impact factor: 3.173

6.  In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension.

Authors:  Alejandro Roldán-Alzate; Alex Frydrychowicz; Eric Niespodzany; Ben R Landgraf; Kevin M Johnson; Oliver Wieben; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-11-12       Impact factor: 4.813

7.  Left atrial flow velocity distribution and flow coherence using four-dimensional FLOW MRI: a pilot study investigating the impact of age and Pre- and Postintervention atrial fibrillation on atrial hemodynamics.

Authors:  Jacob U Fluckiger; Jeffrey J Goldberger; Daniel C Lee; Jason Ng; Richard Lee; Amita Goyal; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2013-01-04       Impact factor: 4.813

8.  Semi-automatic quantification of 4D left ventricular blood flow.

Authors:  Jonatan Eriksson; Carl Johan Carlhäll; Petter Dyverfeldt; Jan Engvall; Ann F Bolger; Tino Ebbers
Journal:  J Cardiovasc Magn Reson       Date:  2010-02-12       Impact factor: 5.364

Review 9.  4D flow imaging with MRI.

Authors:  Zoran Stankovic; Bradley D Allen; Julio Garcia; Kelly B Jarvis; Michael Markl
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

10.  3.0T, time-resolved, 3D flow-sensitive MR in the thoracic aorta: Impact of k-t BLAST acceleration using 8- versus 32-channel coil arrays.

Authors:  Arshad Zaman; Manish Motwani; James J Oliver; Gerard Crelier; Laura E Dobson; David M Higgins; Sven Plein; John P Greenwood
Journal:  J Magn Reson Imaging       Date:  2014-12-02       Impact factor: 4.813

View more
  21 in total

1.  k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

Authors:  Emilie Bollache; Alex J Barker; Ryan Scott Dolan; James C Carr; Pim van Ooij; Rouzbeh Ahmadian; Alex Powell; Jeremy D Collins; Julia Geiger; Michael Markl
Journal:  Magn Reson Med       Date:  2017-03-07       Impact factor: 4.668

2.  Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Hyungkyu Huh; Christoph Forman; Alireza Vali; Andreas Greiser; James Carr; Susanne Schnell; Alex J Barker; Ning Jin
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

3.  Effect of Aortic Valve Disease on 3D Hemodynamics in Patients With Aortic Dilation and Trileaflet Aortic Valve Morphology.

Authors:  Kenichiro Suwa; Ozair Abdul Rahman; Emilie Bollache; Michael J Rose; Amir Ali Rahsepar; James C Carr; Jeremy D Collins; Alex J Barker; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2019-06-06       Impact factor: 4.813

4.  Phase-contrast magnetic resonance imaging for analyzing hemodynamic parameters and wall shear stress of pulmonary arteries in patients with pulmonary arterial hypertension.

Authors:  Hung-Hsuan Wang; Wen-Yih Isaac Tseng; Hsi-Yu Yu; Meng-Chu Chang; Hsu-Hsia Peng
Journal:  MAGMA       Date:  2019-07-03       Impact factor: 2.310

5.  Abnormal torsion and helical flow patterns of the neo-aorta in hypoplastic left heart syndrome assessed with 4D-flow MRI.

Authors:  Dominik Daniel Gabbert; Patrick Trotz; Arash Kheradvar; Michael Jerosch-Herold; Jens Scheewe; Hans-Heiner Kramer; Inga Voges; Carsten Rickers
Journal:  Cardiovasc Diagn Ther       Date:  2021-12

6.  Multivariable Technique for the Evaluation of the Trans-stenotic Pressure Gradient.

Authors:  Junghun Kim; Jongmin Lee; Jieun Park
Journal:  Cardiovasc Eng Technol       Date:  2022-07-25       Impact factor: 2.305

7.  Hemodynamics in a three-dimensional printed aortic model: a comparison of four-dimensional phase-contrast magnetic resonance and image-based computational fluid dynamics.

Authors:  Junghun Kim; Jongmin Lee; Jieun Park; Sinjae Hyun
Journal:  MAGMA       Date:  2022-02-08       Impact factor: 2.533

8.  Identification of intra-individual variation in intracranial arterial flow by MRI and the effect on computed hemodynamic descriptors.

Authors:  Xinke Liu; Evan Kao; Henrik Haraldsson; Megan Ballweber; Alastair Martin; Youxiang Li; Yuting Wang; David Saloner
Journal:  MAGMA       Date:  2021-04-11       Impact factor: 2.533

9.  Patient-Specific Bicuspid Aortic Valve Biomechanics: A Magnetic Resonance Imaging Integrated Fluid-Structure Interaction Approach.

Authors:  Monica Emendi; Francesco Sturla; Ram P Ghosh; Matteo Bianchi; Filippo Piatti; Francesca R Pluchinotta; Daniel Giese; Massimo Lombardi; Alberto Redaelli; Danny Bluestein
Journal:  Ann Biomed Eng       Date:  2020-08-17       Impact factor: 3.934

Review 10.  Advanced cardiovascular multimodal imaging and aortic stenosis.

Authors:  Carmen Cionca; Alexandru Zlibut; Lucia Agoston-Coldea; Teodora Mocan
Journal:  Heart Fail Rev       Date:  2021-07-19       Impact factor: 4.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.