PURPOSE: To evaluate the use of four-dimensional (4D) velocity-encoded magnetic resonance imaging (VEC MRI) for blood flow quantification in patients with semilunar valve stenosis and complex accelerated flow.
MATERIALS AND METHODS: Peak velocities (Vmax) and stroke volumes (SV) were quantified by 2D and 4D VEC MRI in volunteers (n = 7) and patients with semilunar valve stenosis (n = 18). Measurements were performed above the aortic and pulmonary valve with both techniques and, additionally, at multiple predefined planes in the ascending aorta and in the pulmonary trunk within the 4D dataset. In patients, 4D VEC MRI streamline analysis identified flow patterns and regions of highest flow velocity (4D(max-targeted)) for further measurements and Vmax was also measured by Doppler-echocardiography.
RESULTS: In patients, 4D VEC MRI showed higher Vmax than 2D VEC MRI (2.7 ± 0.6 m/s vs. 2.4 ± 0.5 m/s, P < 0.03) and was more comparable to Doppler-echocardiography (2.8 ± 0.7 m/s). 4D(max-targeted) revealed highest Vmax values (3.1 ± 0.6 m/s). SV measurements showed significant differences between different anatomical levels in the ascending aorta in patients with complex accelerated flow, whereas differences in volunteers with laminar flow patterns were negligible (P = 0.004).
CONCLUSION: 4D VEC MRI improves MRI-derived blood flow quantification in patients with semilunar valve stenosis and complex accelerated flow.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22976284     DOI: 10.1002/jmri.23793

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  33 in total

1.  Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics.

Authors:  Emilie Bollache; Pim van Ooij; Alex Powell; James Carr; Michael Markl; Alex J Barker
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-19       Impact factor: 2.357

2.  [Evaluation of mitral regurgitation : How much quantification do we need?]

Authors:  F Kreidel; T Ruf; A Tamm; M Geyer; T Emrich; R S von Bardeleben
Journal:  Herz       Date:  2019-11       Impact factor: 1.443

3.  Suitability of lattice Boltzmann inlet and outlet boundary conditions for simulating flow in image-derived vasculature.

Authors:  Bradley Feiger; Madhurima Vardhan; John Gounley; Matthew Mortensen; Priya Nair; Rafeed Chaudhury; David Frakes; Amanda Randles
Journal:  Int J Numer Method Biomed Eng       Date:  2019-04-01       Impact factor: 2.747

4.  Three-dimensional haemodynamics in patients with obstructive and non-obstructive hypertrophic cardiomyopathy assessed by cardiac magnetic resonance.

Authors:  Bradley D Allen; Lubna Choudhury; Alex J Barker; Pim van Ooij; Jeremy D Collins; Robert O Bonow; James C Carr; Michael Markl
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-08-09       Impact factor: 6.875

Review 5.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

6.  Volumetric velocity measurements in restricted geometries using spiral sampling: a phantom study.

Authors:  Anders Nilsson; Johan Revstedt; Einar Heiberg; Freddy Ståhlberg; Karin Markenroth Bloch
Journal:  MAGMA       Date:  2014-05-18       Impact factor: 2.310

7.  Assessment of altered three-dimensional blood characteristics in aortic disease by velocity distribution analysis.

Authors:  Julio Garcia; Alex J Barker; Pim van Ooij; Susanne Schnell; Jyothy Puthumana; Robert O Bonow; Jeremy D Collins; James C Carr; Michael Markl
Journal:  Magn Reson Med       Date:  2014-09-23       Impact factor: 4.668

8.  4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography.

Authors:  Maya Gabbour; Susanne Schnell; Kelly Jarvis; Joshua D Robinson; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Radiol       Date:  2014-12-09

9.  Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI.

Authors:  Michael J Rose; Kelly Jarvis; Varun Chowdhary; Alex J Barker; Bradley D Allen; Joshua D Robinson; Michael Markl; Cynthia K Rigsby; Susanne Schnell
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

10.  Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI.

Authors:  Daniel Hirtler; Julio Garcia; Alex J Barker; Julia Geiger
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.