Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

Chi Ma1, Lifeng Yu1, Baiyu Chen1, Christopher Favazza1, Shuai Leng1, Cynthia McCollough1.   

Abstract

Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model's template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, [Formula: see text], was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using [Formula: see text] from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO.

Entities:  

Keywords:  channelized Hotelling observer; computed tomography; model observer; radiation dose reduction; task-based image quality assessment

Year:  2016        PMID: 27284547      PMCID: PMC4886187          DOI: 10.1117/1.JMI.3.2.023504

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  25 in total

1.  Effect of dose reduction on the detection of mammographic lesions: a mathematical observer model analysis.

Authors:  Amarpreet S Chawla; Ehsan Samei; Robert Saunders; Craig Abbey; David Delong
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

2.  Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks.

Authors:  Miguel Eckstein; Jay Bartroff; Craig Abbey; James Whiting; Francois Bochud
Journal:  Opt Express       Date:  2003-03-10       Impact factor: 3.894

3.  A methodology for image quality evaluation of advanced CT systems.

Authors:  Joshua M Wilson; Olav I Christianson; Samuel Richard; Ehsan Samei
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

4.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

5.  Effect of reduced radiation exposure and iterative reconstruction on detection of low-contrast low-attenuation lesions in an anthropomorphic liver phantom: an 18-reader study.

Authors:  Ajit H Goenka; Brian R Herts; Nancy A Obuchowski; Andrew N Primak; Frank Dong; Wadih Karim; Mark E Baker
Journal:  Radiology       Date:  2014-03-10       Impact factor: 11.105

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  Adaptive detection mechanisms in globally statistically nonstationary-oriented noise.

Authors:  Yani Zhang; Craig K Abbey; Miguel P Eckstein
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-07       Impact factor: 2.129

8.  Observer Performance in the Detection and Classification of Malignant Hepatic Nodules and Masses with CT Image-Space Denoising and Iterative Reconstruction.

Authors:  Joel G Fletcher; Lifeng Yu; Zhoubo Li; Armando Manduca; Daniel J Blezek; David M Hough; Sudhakar K Venkatesh; Gregory C Brickner; Joseph C Cernigliaro; Amy K Hara; Jeff L Fidler; David S Lake; Maria Shiung; David Lewis; Shuai Leng; Kurt E Augustine; Rickey E Carter; David R Holmes; Cynthia H McCollough
Journal:  Radiology       Date:  2015-05-26       Impact factor: 11.105

9.  Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction.

Authors:  Ke Li; Daniel Gomez-Cardona; Jiang Hsieh; Meghan G Lubner; Perry J Pickhardt; Guang-Hong Chen
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

10.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more
  10 in total

1.  A Web-Based Software Platform for Efficient and Quantitative CT Image Quality Assessment and Protocol Optimization.

Authors:  Mingdong Fan; Theodore Thayib; Liqiang Ren; Scott Hsieh; Cynthia McCollough; David Holmes; Lifeng Yu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

2.  Practical implementation of Channelized Hotelling Observers: Effect of ROI size.

Authors:  Andrea Ferrero; Christopher P Favazza; Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03

3.  Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

Authors:  Christopher P Favazza; Andrea Ferrero; Lifeng Yu; Shuai Leng; Kyle L McMillan; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-03

4.  Rapid measurement of the low contrast detectability of CT scanners.

Authors:  Akinyinka Omigbodun; J Y Vaishnav; Scott S Hsieh
Journal:  Med Phys       Date:  2021-01-13       Impact factor: 4.071

5.  Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

Authors:  Lifeng Yu; Baiyu Chen; James M Kofler; Christopher P Favazza; Shuai Leng; Matthew A Kupinski; Cynthia H McCollough
Journal:  Med Phys       Date:  2017-07-13       Impact factor: 4.071

6.  Localization of liver lesions in abdominal CT imaging: II. Mathematical model observer performance correlates with human observer performance for localization of liver lesions in abdominal CT imaging.

Authors:  Samantha K N Dilger; Shuai Leng; Baiyu Chen; Rickey E Carter; Chris P Favazza; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Phys Med Biol       Date:  2019-05-10       Impact factor: 3.609

7.  Efficient Evaluation of Low-contrast Detectability of Deep-CNN-based CT Reconstruction Using Channelized Hotelling Observer on the ACR Accreditation Phantom.

Authors:  Mingdong Fan; Zhongxing Zhou; Thomas Vrieze; Jia Wang; Cynthia McCollough; Lifeng Yu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

8.  Determination of Optimal Image Type and Lowest Detectable Concentration for Iodine Detection on a Photon Counting Detector-Based Multi-Energy CT System.

Authors:  Wei Zhou; Rachel Schornak; Gregory Michalak; Jayse Weaver; Dilbar Abdurakhimova; Andrea Ferrero; Kenneth A Fetterly; Cynthia H McCollough; Shuai Leng
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03

9.  Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system.

Authors:  Wei Zhou; Gregory Michalak; Jayse Weaver; Andrea Ferrero; Hao Gong; Kenneth A Fetterly; Cynthia H McCollough; Shuai Leng
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

Review 10.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.