Literature DB >> 31620546

Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system.

Wei Zhou1, Gregory Michalak1, Jayse Weaver1, Andrea Ferrero1, Hao Gong1, Kenneth A Fetterly1,2, Cynthia H McCollough1, Shuai Leng1.   

Abstract

In addition to low-energy-threshold images (TLIs), photon-counting detector (PCD) computed tomography (CT) can generate virtual monoenergetic images (VMIs) and iodine maps. Our study sought to determine the image type that maximizes iodine detectability. Adult abdominal phantoms with iodine inserts of various concentrations and lesion sizes were scanned on a PCD-CT system. TLIs, VMIs at 50 keV, and iodine maps were generated, and iodine contrast-to-noise ratio (CNR) was measured. A channelized Hotelling observer was used to determine the area under the receiver-operating-characteristic curve (AUC) for iodine detectability. Iodine map CNR ( 0.57 ± 0.42 ) was significantly higher ( P < 0.05 ) than for TLIs ( 0.46 ± 0.26 ) and lower ( P < 0.001 ) than for VMIs at 50 keV ( 0.74 ± 0.33 ) for 0.5 mgI/cc and a 35-cm phantom. For the same condition and an 8-mm lesion, iodine detectability from iodine maps ( AUC = 0.95 ± 0.01 ) was significantly lower ( P < 0.001 ) than both TLIs ( AUC = 0.99 ± 0.00 ) and VMIs ( AUC = 0.99 ± 0.01 ). VMIs at 50 keV had similar detectability to TLIs and both outperformed iodine maps. The lowest detectable iodine concentration was 0.5 mgI/cc for an 8-mm lesion and 1.0 mgI/cc for a 4-mm lesion.
© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  channelized Hotelling observer; iodine detectability; iodine maps; photon-counting detector computed tomography; virtual monoenergetic images

Year:  2019        PMID: 31620546      PMCID: PMC6792003          DOI: 10.1117/1.JMI.6.4.043501

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  41 in total

1.  Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality.

Authors:  Lifeng Yu; Jodie A Christner; Shuai Leng; Jia Wang; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Minimally Required Iodine Dose for the Detection of Hypervascular Hepatocellular Carcinoma on 80-kVp CT.

Authors:  Satoshi Goshima; Masayuki Kanematsu; Yoshifumi Noda; Nobuyuki Kawai; Hiroshi Kawada; Hiromi Ono; Kyongtae T Bae
Journal:  AJR Am J Roentgenol       Date:  2016-03       Impact factor: 3.959

3.  Detection and classification of focal liver lesions in patients with colorectal cancer: retrospective comparison of diffusion-weighted MR imaging and multi-slice CT.

Authors:  Matthias Eiber; Alexander A Fingerle; Melanie Brügel; Jochen Gaa; Ernst J Rummeny; Konstantin Holzapfel
Journal:  Eur J Radiol       Date:  2011-02-12       Impact factor: 3.528

4.  Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

Authors:  Chi Ma; Lifeng Yu; Baiyu Chen; Christopher Favazza; Shuai Leng; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-05-26

5.  Predicting detection performance with model observers: Fourier domain or spatial domain?

Authors:  Baiyu Chen; Lifeng Yu; Shuai Leng; James Kofler; Christopher Favazza; Thomas Vrieze; Cynthia McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-30

6.  Objective image characterization of a spectral CT scanner with dual-layer detector.

Authors:  Orhan Ozguner; Amar Dhanantwari; Sandra Halliburton; Gezheng Wen; Steven Utrup; David Jordan
Journal:  Phys Med Biol       Date:  2018-01-16       Impact factor: 3.609

7.  Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system.

Authors:  Wei Zhou; Juan Montoya; Ralf Gutjahr; Andrea Ferrero; Ahmed Halaweish; Steffen Kappler; Cynthia McCollough; Shuai Leng
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-16

8.  Detection and Characterization of Renal Stones by Using Photon-Counting-based CT.

Authors:  Roy P Marcus; Joel G Fletcher; Andrea Ferrero; Shuai Leng; Ahmed F Halaweish; Ralf Gutjahr; Terri J Vrtiska; Mike L Wells; Felicity T Enders; Cynthia H McCollough
Journal:  Radiology       Date:  2018-08-07       Impact factor: 11.105

9.  Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study.

Authors:  G Jay Hanson; Gregory J Michalak; Robert Childs; Brian McCollough; Anil N Kurup; David M Hough; Judson M Frye; Jeff L Fidler; Sudhakar K Venkatesh; Shuai Leng; Lifeng Yu; Ahmed F Halaweish; W Scott Harmsen; Cynthia H McCollough; J G Fletcher
Journal:  Abdom Radiol (NY)       Date:  2018-06

Review 10.  Imaging of hepatocellular carcinoma: diagnosis, staging and treatment monitoring.

Authors:  Tiffany Hennedige; Sudhakar Kundapur Venkatesh
Journal:  Cancer Imaging       Date:  2013-02-08       Impact factor: 3.909

View more
  1 in total

1.  Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance.

Authors:  Davide Cester; Matthias Eberhard; Hatem Alkadhi; André Euler
Journal:  Quant Imaging Med Surg       Date:  2022-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.