| Literature DB >> 27091025 |
José Ignacio Fernández-Vigo1,2, Julián García-Feijóo3, José María Martínez-de-la-Casa3, Javier García-Bella3, Pedro Arriola-Villalobos3, Cristina Fernández-Pérez4, José Ángel Fernández-Vigo5,6.
Abstract
BACKGROUND: Recently, novel anatomic parameters that can be measured by optical coherence tomography (OCT), have been identified as a more objective and accurate method of defining the iridocorneal angle. The aim of the present study is to measure the iridocorneal angle by Fourier domain (FD) OCT and to identify correlations between angle measurements and subject factors in a large healthy Caucasian population.Entities:
Keywords: Anterior chamber; Glaucoma; Iridocorneal angle; Optical coherence tomography
Mesh:
Year: 2016 PMID: 27091025 PMCID: PMC4835848 DOI: 10.1186/s12886-016-0219-z
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Examples of iridocorneal angle measurements made by Fourier Domain optical coherence tomography images. a Trabecular-iris angle (TIA) and (b) Angle opening distance 500 μm from the scleral spur (AOD500) and trabecular-iris space area (TISA500) 500 μm from the scleral spur in a normal angle width. c and d TIA, AOD500 and TISA500 measurements in a narrow angle. e and (f) TIA, AOD500 and TISA500 measurements in a wide angle
Measurements made in the study population using the Pentacam and the IOL Master
| Ocular characteristics of the study subjects | ||||||
|---|---|---|---|---|---|---|
| Pentacam® | IOL Master® | |||||
| ACD (mm) | CCT (μm) | ACV (mm3) | Axial length (mm) | WTW (mm) | Pupil diameter (mm) | |
| Mean | 3.35 | 550.6 | 161.8 | 23.87 | 12.11 | 4.26 |
| SD | 0.43 | 31.9 | 48.0 | 1.54 | 0.41 | 0.98 |
| Maximum | 4.61 | 643 | 265 | 33.61 | 13.40 | 6.45 |
| Minimum | 2.16 | 474 | 67 | 20.02 | 10.90 | 2.10 |
ACD anterior chamber depth, CCT central corneal thickness, ACV anterior chamber volume, WTW white-to-white or corneal diameter, SD standard deviation
Intra- and interobserver reproducibility of anterior chamber angle measurements made by Fourier Domain OCT
| Intraobserver reproducibility | Mean ± SD | ICC | 95 % CI |
|
| TIA Session 1 (degrees) | 33.66 ± 11.38 | 0.979 | 0.969–0.986 | <0.001 |
| TIA Session 2 (degrees) | 33.69 ± 10.94 | |||
| AOD500 Session 1 (μm) | 491.16 ± 281.25 | 0.991 | 0.987–0.994 | <0.001 |
| AOD500 Session 2 (μm) | 492.02 ± 280.84 | |||
| TISA500 Session 1 (mm2) | 0.178 ± 0.104 | 0.962 | 0.944–0.974 | <0.001 |
| TISA500 Session 2 (mm2) | 0.181 ± 0.112 | |||
| Interobserver reproducibility | Mean ± SD | ICC | 95 % CI |
|
| TIA Observer 1 (degrees) | 33.66 ± 11.38 | 0.954 | 0.933–0.969 | <0.001 |
| TIA Observer 2 (degrees) | 33.03 ± 10.55 | |||
| AOD500 Observer 1 (μm) | 491.16 ± 281.25 | 0.975 | 0.964–0.983 | <0.001 |
| AOD500 Observer 2 (μm) | 480.15 ± 295.72 | |||
| TISA500 Observer 1 (mm2) | 0.178 ± 0.104 | 0.947 | 0.922–0.964 | <0.001 |
| TISA500 Observer 2 (mm2) | 0.174 ± 0.116 |
TIA trabecular-iris angle, AOD angle opening distance 500 μm from the scleral spur, TISA trabecular-iris space area 500 μm from the scleral spur. ICC intraclass correlation coefficient, 95 % CI = 95 % confidence interval
Fig. 2a Relationship between trabecular-iris angle (TIA) and age. Angle width measurements diminished from 18 years to 56–60 years, and stabilized thereafter. b Relationship between TIA and spherical refractive error. Mean trabecular-iris angle (TIA) was stable over the range < -9 to -3 diopters, point from which it was decreasing progressively toward hyperopia
Correlations between the angle parameters (TIA, AOD500 and TISA500) and different factors of the subjects
| Demographic and ocular correlations with TIA, AOD500 and TISA500 | |||
|---|---|---|---|
| Factor | TIA | AOD500 | TISA500 |
| Age | -0.496 ( | -0.484 ( | -0.454 ( |
| ACD | -0.818 ( | 0.760 ( | 0.732 ( |
| IOP | -0.052 ( | -0.069 ( | -0.076 ( |
| CCT | -0.095 ( | -0.092 ( | -0.086 ( |
| ACV | 0.848 ( | 0.802 ( | 0.769 ( |
| Pupil size | 0.179 ( | 0.187 ( | 0.159 ( |
| WTW | 0.269 ( | 0.228 ( | 0.216 ( |
| Axial length | 0.599 ( | 0.570 ( | 0.562 ( |
| Spherical error | -0.575 ( | -0.545 ( | -0.540 ( |
| Iris thickness | 0.151 ( | 0.188 ( | 0.208 ( |
TIA trabecular-iris angle, AOD angle opening distance 500 μm from the scleral spur, TISA trabecular-iris space area 500 μm from the scleral spur, ACD anterior chamber depth, IOP intraocular pressure, CCT central corneal thickness, ACV anterior chamber volume, WTW white to white or corneal diameter