Literature DB >> 19273787

High-definition optical coherence tomography imaging of the iridocorneal angle of the eye.

Hon-Tym Wong1, Marcus C Lim, Lisandro M Sakata, Han T Aung, Nishani Amerasinghe, David S Friedman, Tin Aung.   

Abstract

OBJECTIVE: To assess the ability of high-definition optical coherence tomography (HD-OCT) to image the anterior chamber angle.
METHODS: Forty-five consecutive subjects with phakic eyes underwent gonioscopy and anterior chamber angle imaging with HD-OCT adapted with a 60-diopter aspheric lens mounted over the imaging aperture. The patients' fixation was directed to the side using an external fixation light, and scans were taken of the temporal and nasal quadrants. The visibility of angle structures was assessed and the diagnosis of angle closure using HD-OCT was compared with that of gonioscopy.
RESULTS: The majority of subjects were Chinese (91.1%) and female (62.2%). Cross-sectional HD-OCT allowed in vivo visualization of the scleral spur in 71 of 90 quadrants (78.9%) and the termination of the Descemet membrane (Schwalbe line) in 84 of 90 quadrants (93.3%). It was possible to image the trabecular meshwork in 56 quadrants (62.2%). Angle closure was observed in 17 eyes with gonioscopy and 12 eyes with HD-OCT (P = .12, McNemar test). The 2 modalities showed good agreement for angle closure diagnosis by quadrant (kappa = 0.65).
CONCLUSION: The adapted HD-OCT provided magnified views of the anterior chamber angle and allowed visualization of the Schwalbe line and trabecular meshwork in most eyes.

Entities:  

Mesh:

Year:  2009        PMID: 19273787     DOI: 10.1001/archophthalmol.2009.22

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  28 in total

1.  Scanning beyond the limits of standard OCT with a Fourier domain optical coherence tomography integrated into a slit lamp: the SL SCAN-1.

Authors:  M Stehouwer; F D Verbraak; H R de Vries; T G van Leeuwen
Journal:  Eye (Lond)       Date:  2010-11-12       Impact factor: 3.775

2.  Complete 360° circumferential gonioscopic optical coherence tomography imaging of the iridocorneal angle.

Authors:  Ryan P McNabb; Pratap Challa; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2015-03-20       Impact factor: 3.732

3.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

4.  Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography.

Authors:  Elton Lik Tong Tay; Vernon Khet Yau Yong; Boon Ang Lim; Stelson Sia; Elizabeth Poh Ying Wong; Leonard Wei Leon Yip
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

Review 5.  Old and new in exploring the anterior chamber angle.

Authors:  Moisescu Raluca; Filip Mircea; Filip Andrei; Dragne Carmen; Nicolae Miruna; Triantafyllidis Grigorios; Ungureanu Ileana
Journal:  Rom J Ophthalmol       Date:  2015 Oct-Dec

6.  Anterior chamber angle measurements using Schwalbe's line with high-resolution fourier-domain optical coherence tomography.

Authors:  Bing Qin; Brian A Francis; Yan Li; Maolong Tang; Xinbo Zhang; Chunhui Jiang; Catherine Cleary; David Huang
Journal:  J Glaucoma       Date:  2013-12       Impact factor: 2.503

7.  Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT.

Authors:  Handan Akil; Kenneth Marion; Anna Dastiridou; Dennis Jenkins; Brendan Kramer; Brian A Francis; Vikas Chopra
Journal:  Int Ophthalmol       Date:  2016-03-24       Impact factor: 2.031

8.  Investigation of gold-coated bare fiber probe for in situ intra-vitreous coherence domain optical imaging and sensing.

Authors:  J-H Han; I K Ilev; D-H Kim; C G Song; J U Kang
Journal:  Appl Phys B       Date:  2010-06-01       Impact factor: 2.070

9.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28

10.  Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure.

Authors:  Sue-Wei Ho; Mani Baskaran; Ce Zheng; Tin A Tun; Shamira A Perera; Arun K Narayanaswamy; David S Friedman; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-23       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.