Literature DB >> 33259236

Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Aline Pf Caetano1, Thiago O Sousa2, Mariana R Oliveira1, Karine Evanglista1, Juliano M Bueno3, Maria Ag Silva1.   

Abstract

OBJECTIVES: The aim of this study was to compare the accuracy of vertical root fracture (VRF) detection using three tomography devices and two software systems in teeth with different endodontic fillings.
METHODS: The sample consisted of 45 premolars divided into 3 groups: No filling (NF, n=15); Gutta percha (GP, n=15) and Metallic Post (MP, n=15). Cone-beam computed tomography (CBCT) images were acquired in Kodak 9000 3D, Orthopantomography 300 (OP300) and PreXion 3D devices, before and after induced root fractures. Two oral radiologists analyzed all images using InVivoDental and e-Vol DX software systems. The analysis was repeated after 15 days in 30% of the sample. Data analysis compared receiver operating characteristic (ROC) curves, as well the areas under the ROC curves. Accuracy, sensitivity, specificity, positive and negative predictive value were calculated according to each tomographic device and software. Intra- and interexaminer reliability were tested using the Kappa coefficient.
RESULTS: The highest accuracy was seen in the image set from the PreXion 3D, using InVivo (0.96) or e-Vol DX (0.92) in image analysis. The OP300 device presented a similar performance of the PreXion 3D in teeth with different endodontic fillings. When using e-Vol DX, the accuracy of Kodak 9000 3D improved from 0.62 to 0.74.
CONCLUSIONS: The PreXion 3D device is the most accurate when detecting VRF, with a performance similar to the OP300 in endodontic filled teeth. Kodak 9000 3D is indicated for teeth without fillings, with better accuracy using e-Vol DX software.

Entities:  

Keywords:  cone-beam computed tomography; diagnostic imaging; tooth fracture

Mesh:

Year:  2020        PMID: 33259236      PMCID: PMC7923069          DOI: 10.1259/dmfr.20200334

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  44 in total

1.  Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view.

Authors:  Sara Lofthag-Hansen; Anne Thilander-Klang; Kerstin Gröndahl
Journal:  Eur J Radiol       Date:  2010-10-20       Impact factor: 3.528

2.  Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views.

Authors:  Marina Codari; Karla de Faria Vasconcelos; Laura Ferreira Pinheiro Nicolielo; Francisco Haiter Neto; Reinhilde Jacobs
Journal:  Clin Oral Implants Res       Date:  2017-04-22       Impact factor: 5.977

3.  Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines.

Authors:  Boulos Bechara; Clyde A McMahan; William S Moore; Marcel Noujeim; Hassem Geha; Fabricio B Teixeira
Journal:  J Oral Sci       Date:  2012-09       Impact factor: 1.556

4.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

5.  Influence of root embedment material and periodontal ligament simulation on fracture resistance tests.

Authors:  Carlos José Soares; Eliane Cristina Gava Pizi; Rodrigo Borges Fonseca; Luis Roberto Marcondes Martins
Journal:  Braz Oral Res       Date:  2005 Jan-Mar

6.  Use of cone-beam volumetric tomography in the diagnosis of root fractures.

Authors:  Ricardo Affonso Bernardes; Ivaldo Gomes de Moraes; Marco Antonio Húngaro Duarte; Bruno C Azevedo; José Ribamar de Azevedo; Clovis Monteiro Bramante
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-03-09

7.  Diagnosis of Mesiodistal Vertical Root Fractures in Teeth with Metal Posts: Influence of Applying Filters in Cone-beam Computed Tomography Images at Different Resolutions.

Authors:  Débora De Martin E Silva; Celso Neiva Campos; Antônio Carlos Pires Carvalho; Karina Lopes Devito
Journal:  J Endod       Date:  2017-11-16       Impact factor: 4.171

8.  Diagnosis of alveolar and root fractures: an in vitro study comparing CBCT imaging with periapical radiographs.

Authors:  Solange Kobayashi-Velasco; Fernanda Cristina Sales Salineiro; Ivan Onone Gialain; Marcelo Gusmão Paraiso Cavalcanti
Journal:  J Appl Oral Sci       Date:  2017 Mar-Apr       Impact factor: 2.698

9.  Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials.

Authors:  Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Yuri Wanderley Cavalcanti; Elisa Diniz de Lima; Patrícia Meira Bento; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2020-06-18

Review 10.  Vertical root fracture: Biological effects and accuracy of diagnostic imaging methods.

Authors:  Turki M Baageel; Emad Habib Allah; Ghaida T Bakalka; Fatima Jadu; Ibrahim Yamany; Ahmed M Jan; Dania F Bogari; Turki Y Alhazzazi
Journal:  J Int Soc Prev Community Dent       Date:  2016-08