Literature DB >> 23601223

Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study.

Boulos Bechara1, C Alex McMahan, Ibrahim Nasseh, Hassem Geha, Elie Hayek, Georges Khawam, Michel Raad, Marcel Noujeim.   

Abstract

OBJECTIVES: The objective of this study was to compare the accuracy of root fracture detection in endodontically treated teeth using scans acquired with a 180° rotation motion compared with a 360° after which the patient exposure and number of basis images are doubled.
METHODS: Sixty-six roots were collected and decoronated. All were treated endodontically. One-half of the roots were fractured, resulting in 2 root fragments which were then glued together. The roots were placed randomly in 8 prepared beef rib fragments. Five reviewers independently reviewed the scans twice, at different times.
RESULTS: The specificity of the 360° scan was significantly higher than the 180° scan; doubling the basis images leads to a significant decrease in false-positive rates. Accuracy and sensitivity were not significantly different.
CONCLUSIONS: Only the specificity is improved by the increased rotation and doubling of images. The accuracy and sensitivity are not improved.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23601223     DOI: 10.1016/j.oooo.2013.01.026

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol


  12 in total

1.  Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts.

Authors:  I S Q Bezerra; F S Neves; T V Vasconcelos; G M B Ambrosano; D Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2015-03-12       Impact factor: 2.419

2.  Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study.

Authors:  Husniye Demirturk Kocasarac; Dilek Helvacioglu Yigit; Boulos Bechara; Alper Sinanoglu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2016-03-08       Impact factor: 2.419

Review 3.  Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT: a systematic review.

Authors:  Rebekah Goulston; Jonathan Davies; Keith Horner; Frederick Murphy
Journal:  Dentomaxillofac Radiol       Date:  2016-01-06       Impact factor: 2.419

4.  Influence of scan mode (partial/full rotations) and FOV size in the formation of artefacts in cone beam CT.

Authors:  Eliana Dantas da Costa; Polyane Mazucatto Queiroz; Gustavo Machado Santaella; Ana Lúcia Alvares Capelozza; Glaucia Maria Bovi Ambrosano; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2019-01-11       Impact factor: 2.419

5.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

6.  Feasibility of micro-computed tomography to detect and classify proximal caries lesions in vitro.

Authors:  Karla Rovaris; Liana Matos Ferreira; Thiago Oliveira Sousa; Leonardo Vieira Peroni; Deborah Queiroz Freitas; Ann Wenzel; Francisco Haiter-Neto
Journal:  Dent Res J (Isfahan)       Date:  2018 Mar-Apr

Review 7.  Vertical root fracture: Biological effects and accuracy of diagnostic imaging methods.

Authors:  Turki M Baageel; Emad Habib Allah; Ghaida T Bakalka; Fatima Jadu; Ibrahim Yamany; Ahmed M Jan; Dania F Bogari; Turki Y Alhazzazi
Journal:  J Int Soc Prev Community Dent       Date:  2016-08

8.  Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites.

Authors:  Aditya Tadinada; Alana Marczak; Sumit Yadav
Journal:  Imaging Sci Dent       Date:  2017-09-21

9.  Cone beam CT optimisation for detection of vertical root fracture with metal in the field of view or the exomass.

Authors:  Amanda P Candemil; Benjamin Salmon; Karla F Vasconcelos; Anne C Oenning; Reinhilde Jacobs; Deborah Q Freitas; Francisco Haiter-Neto; Francesca Mangione; Matheus L Oliveira
Journal:  Sci Rep       Date:  2021-09-27       Impact factor: 4.379

10.  Metal artifact production and reduction in CBCT with different numbers of basis images.

Authors:  Polyane Mazucatto Queiroz; Gustavo Machado Santaella; Francisco Carlos Groppo; Deborah Queiroz Freitas
Journal:  Imaging Sci Dent       Date:  2018-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.