Estimation of contrast-to-noise ratio in CT and CBCT images with varying scan settings in presence of different implant materials.

Emine Şebnem Kursun-Cakmak1, Husniye Demirturk Kocasarac2, Seval Bayrak3, Gülbahar Ustaoğlu4, Marcel Noujeim5.   

Abstract

OBJECTIVES: To assess the contrast-to-noise ratio (CNR) of four different types of dental implant materials in CT and cone beam CT (CBCT) images with varying scan settings.
METHODS: Four different types of implants: zirconium (Zr), titanium (Ti) Grade 4 and 5 and titanium-zirconium (Ti-ZrO2) alloy were placed in a 3% gelatin phantom in a cylindrical plastic container and scanned with two different CT machines (GE Medical systems and Toshiba Medical Systems) and one CBCT machine (I-CAT, Imaging Sciences International) with different voxel sizes of 0.2, 0.25, 0.3 and 0.4 mm. Images were analyzed using ImageJ software with the purpose of estimating the CNR.
RESULTS: The CNR obtained from images acquired with CT was lower than the CBCT with all voxel sizes tested. 0.3 and 0.4 mm voxel sizes exhibited the highest CNR (p < 0.05) that gives the best image quality. Among the implant materials tested, titanium Grade 5 has the highest levels of CNR while Zirconium has the lowest (p < 0.05).
CONCLUSIONS: The optimum protocol for radiographic follow-up in areas near implants on the I-CAT is low-resolution settings (0.3 and 0.4 mm voxel sizes) which gave the highest CNR thus image quality. In presence of Zr implants, an alternative imaging modality (i.e., MRI) may be considered to avoid low-quality images.

Entities:  

Keywords:  cone beam computed tomography; contrast-to-noise ratio; dental implant

Mesh:

Substances:

Year:  2019        PMID: 31386553      PMCID: PMC6951101          DOI: 10.1259/dmfr.20190139

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  14 in total

Review 1.  Zirconia dental implants: a literature review.

Authors:  Zeynep Özkurt; Ender Kazazoğlu
Journal:  J Oral Implantol       Date:  2010-06-14       Impact factor: 1.779

2.  The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode.

Authors:  Fatma Cebe; Ali Murat Aktan; Abdul Semih Ozsevik; Mehmet Ertugrul Ciftci; Hatice Derya Surmelioglu
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2016-12-07

3.  Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines.

Authors:  Boulos Bechara; Clyde A McMahan; William S Moore; Marcel Noujeim; Hassem Geha; Fabricio B Teixeira
Journal:  J Oral Sci       Date:  2012-09       Impact factor: 1.556

4.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

5.  Clinical evaluation of the iterative metal artefact reduction algorithm for post-operative CT examination after maxillofacial surgery.

Authors:  Arsany Hakim; Johannes Slotboom; Olivier Lieger; Fabian Schlittler; Roland Giger; Chantal Michel; Roland Wiest; Franca Wagner
Journal:  Dentomaxillofac Radiol       Date:  2017-03-07       Impact factor: 2.419

6.  Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

Authors:  Ralf Smeets; Maximilian Schöllchen; Tobias Gauer; Ghazal Aarabi; Alexandre T Assaf; Carsten Rendenbach; Benedicta Beck-Broichsitter; Jan Semmusch; Jan Sedlacik; Max Heiland; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2016-12-02       Impact factor: 2.419

7.  A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose.

Authors:  R Pauwels; O Silkosessak; R Jacobs; R Bogaerts; H Bosmans; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2014-04-08       Impact factor: 2.419

8.  Techniques for dental implant nanosurface modifications.

Authors:  Preeti Pachauri; Lakshmana Rao Bathala; Rajashekar Sangur
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

9.  Characterization of Scattered X-Ray Photons in Dental Cone-Beam Computed Tomography.

Authors:  Ching-Ching Yang
Journal:  PLoS One       Date:  2016-03-07       Impact factor: 3.240

Review 10.  Binary titanium alloys as dental implant materials-a review.

Authors:  Xiaotian Liu; Shuyang Chen; James K H Tsoi; Jukka Pekka Matinlinna
Journal:  Regen Biomater       Date:  2017-09-23
View more
  2 in total

1.  Image-Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions of Unenhanced CT Scans of the Head: Initial Experiences with the First Photon-Counting CT Approved for Clinical Use.

Authors:  Arwed Elias Michael; Jan Boriesosdick; Denise Schoenbeck; Matthias Michael Woeltjen; Saher Saeed; Jan Robert Kroeger; Sebastian Horstmeier; Simon Lennartz; Jan Borggrefe; Julius Henning Niehoff
Journal:  Diagnostics (Basel)       Date:  2022-01-21

Review 2.  The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review.

Authors:  Paweł Sawicki; Paweł J Zawadzki; Piotr Regulski
Journal:  Cureus       Date:  2022-03-10
  2 in total