Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines.

Boulos Bechara1, Clyde A McMahan, William S Moore, Marcel Noujeim, Hassem Geha, Fabricio B Teixeira.   

Abstract

Each of three cone beam computed tomography (CBCT) machines offer a small field of view (FOV); Promax, Accuitomo 3D, and Kodak 9000. The objectives were to determine, when using a small FOV, the difference in contrast-to-noise ratios (CNR) of images obtained from different machines and different scan settings within each machine. A phantom made of a dry mandible with an epoxy resin based substitute (ERBS) block was used. The ERBS block was fixed to the lingual cortex in the posterior left mandible. Water was used to simulate soft tissue. Twenty scans were acquired. CNR was calculated as the difference in density of the ERBS block and a control area divided by the standard deviation of the difference. The CNR obtained from images acquired with the Promax machine (voxel size of 0.2 mm) was higher than the other machines (voxel sizes 0.076, 0.08, or 0.125 mm) when using a small FOV. The Accuitomo 360° scan had higher CNR than the Accuitomo 180° scan due to the doubling of the number of basis images acquired. Smaller voxel size does not necessarily lead to enhanced CNR. Increasing the number of basis images did increase the CNR.

Entities:  

Mesh:

Year:  2012        PMID: 23047033     DOI: 10.2334/josnusd.54.227

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  23 in total

1.  Is dual-phase C-arm CBCT sufficiently accurate for the diagnosis of colorectal cancer liver metastasis during liver intra-arterial treatment?

Authors:  Olivier Pellerin; Helena Pereira; Claire Van Ngoc Ty; Nadia Moussa; Costantino Del Giudice; Simon Pernot; Carole Déan; Gilles Chatellier; Marc Sapoval
Journal:  Eur Radiol       Date:  2019-04-01       Impact factor: 5.315

2.  The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013-10-16       Impact factor: 2.419

3.  Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; P Nambiar
Journal:  Dentomaxillofac Radiol       Date:  2013-11-21       Impact factor: 2.419

4.  Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT.

Authors:  E Klintström; O Smedby; B Klintström; T B Brismar; R Moreno
Journal:  Dentomaxillofac Radiol       Date:  2014-08-29       Impact factor: 2.419

5.  The influence of amalgam fillings on the detection of approximal caries by cone beam CT: in vitro study.

Authors:  T Kulczyk; M Dyszkiewicz Konwińska; M Owecka; J Krzyżostaniak; A Surdacka
Journal:  Dentomaxillofac Radiol       Date:  2014-07-02       Impact factor: 2.419

6.  Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study.

Authors:  Husniye Demirturk Kocasarac; Dilek Helvacioglu Yigit; Boulos Bechara; Alper Sinanoglu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2016-03-08       Impact factor: 2.419

7.  Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth.

Authors:  B Bechara; C A McMahan; M Noujeim; T Faddoul; W S Moore; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-04-26       Impact factor: 2.419

8.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

9.  Estimation of contrast-to-noise ratio in CT and CBCT images with varying scan settings in presence of different implant materials.

Authors:  Emine Şebnem Kursun-Cakmak; Husniye Demirturk Kocasarac; Seval Bayrak; Gülbahar Ustaoğlu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2019-08-09       Impact factor: 2.419

10.  Micro-CT imaging of Thiel-embalmed and iodine-stained human temporal bone for 3D modeling.

Authors:  Sebastian Halm; David Haberthür; Elisabeth Eppler; Valentin Djonov; Andreas Arnold
Journal:  J Otolaryngol Head Neck Surg       Date:  2021-06-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.