Literature DB >> 23520395

Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

B Bechara1, C Alex McMahan, W S Moore, M Noujeim, F B Teixeira, H Geha.   

Abstract

OBJECTIVES: Cone beam CT (CBCT) is used widely to depict root fracture (RF) in endodontically treated teeth. Beam hardening and other artefacts due to gutta-percha may increase the time of the diagnosis and result in an incorrect diagnosis. Two CBCT machines, ProMax(®) (Planmeca, Helsinki, Finland) and Master 3D(®) (Vatech, Hwaseong, Republic of Korea), have the option of applying an artefact reduction (AR) algorithm. The aim of this study was to determine whether using an AR algorithm in two CBCT machines enhances the accuracy of detecting RFs in endodontically treated teeth.
METHODS: 66 roots were collected and decoronated. All roots were treated endodontically using the same technique with gutta-percha and zinc oxide cement. One-half of the roots were randomly selected and fractured using a nail that was tapped gently with a hammer until complete fracture resulted in two root fragments; the two root fragments were glued together with one layer of methyl methacrylate. The roots were placed randomly in eight prepared beef rib fragments.
RESULTS: The highest accuracy was obtained when the ProMax was used without AR. The lowest accuracy was obtained with the Master 3D when used with AR. For both machines, accuracy was significantly higher without AR than with AR. Both with and without AR, the ProMax machine was significantly more accurate than the Master 3D machine. The same rank ordering was obtained for both sensitivity and specificity.
CONCLUSIONS: For both machines, AR decreased the accuracy of RF detection in endodontically treated teeth. The highest accuracy was obtained when using the ProMax without AR.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23520395      PMCID: PMC3635776          DOI: 10.1259/dmfr.20120245

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  27 in total

1.  The effects of beam hardening on digital subtraction radiography.

Authors:  R L Webber; A Tzukert; U Ruttimann
Journal:  J Periodontal Res       Date:  1989-01       Impact factor: 4.419

2.  Clinical applications of cone-beam computed tomography in dental practice.

Authors:  William C Scarfe; Allan G Farman; Predag Sukovic
Journal:  J Can Dent Assoc       Date:  2006-02       Impact factor: 1.316

3.  Three-dimensional, non-destructive visualization of vertical root fractures using flat panel volume detector computer tomography: an ex vivo in vitro case report.

Authors:  C Hannig; C Dullin; M Hülsmann; G Heidrich
Journal:  Int Endod J       Date:  2005-12       Impact factor: 5.264

4.  Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants.

Authors:  D D Robertson; P J Weiss; E K Fishman; D Magid; P S Walker
Journal:  J Comput Assist Tomogr       Date:  1988 Mar-Apr       Impact factor: 1.826

5.  Radiographic features of vertically fractured endodontically treated mesial roots of mandibular molars.

Authors:  Aviad Tamse; Israel Kaffe; Joseph Lustig; Yehuda Ganor; Zvi Fuss
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-03-24

6.  Contrast-to-noise ratio with different large volumes in a cone-beam computerized tomography machine: an in vitro study.

Authors:  Boulos Bechara; C Alex McMahan; William S Moore; Marcel Noujeim; Hassem Geha
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2012-11

7.  Dental vertical root fractures: value of CT in detection.

Authors:  S Youssefzadeh; A Gahleitner; R Dorffner; T Bernhart; F M Kainberger
Journal:  Radiology       Date:  1999-02       Impact factor: 11.105

8.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

Review 9.  Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.

Authors:  Bruno Vande Berg; Jacques Malghem; Baudouin Maldague; Frederic Lecouvet
Journal:  Eur J Radiol       Date:  2006-10-31       Impact factor: 3.528

10.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement.

Authors:  Andreas H Mahnken; Rainer Raupach; Joachim E Wildberger; Bettina Jung; Nicole Heussen; Thomas G Flohr; Rolf W Günther; Stefan Schaller
Journal:  Invest Radiol       Date:  2003-12       Impact factor: 6.016

View more
  38 in total

1.  Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode.

Authors:  K Kamburoglu; E Kolsuz; S Murat; H Eren; S Yüksel; C S Paksoy
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

2.  Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts.

Authors:  L M Ferreira; M A P G Visconti; H A Nascimento; R R Dallemolle; G M Ambrosano; D Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

3.  Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts.

Authors:  I S Q Bezerra; F S Neves; T V Vasconcelos; G M B Ambrosano; D Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2015-03-12       Impact factor: 2.419

4.  Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOV.

Authors:  Polyane M Queiroz; Gustavo M Santaella; Thais D J da Paz; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

Review 5.  Quality assurance phantoms for cone beam computed tomography: a systematic literature review.

Authors:  Marcus V L de Oliveira; Ann Wenzel; Paulo S F Campos; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

6.  Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts.

Authors:  Deborah Queiroz Freitas; Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Taruska Ventorini Vasconcelos; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

7.  Assessment of metal artefact reduction around dental titanium implants in cone beam CT.

Authors:  A Parsa; N Ibrahim; B Hassan; K Syriopoulos; P van der Stelt
Journal:  Dentomaxillofac Radiol       Date:  2014-08-19       Impact factor: 2.419

8.  Variation in voxel value distribution and effect of time between exposures in six CBCT units.

Authors:  R Spin-Neto; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2014-02-03       Impact factor: 2.419

9.  Differential diagnosis of vertical root fractures using reconstructed three-dimensional models of bone defects.

Authors:  K Komatsu; Y Abe; T Yoshioka; H Ishimura; A Ebihara; H Suda
Journal:  Dentomaxillofac Radiol       Date:  2014-09-23       Impact factor: 2.419

10.  Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study.

Authors:  Husniye Demirturk Kocasarac; Dilek Helvacioglu Yigit; Boulos Bechara; Alper Sinanoglu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2016-03-08       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.