| Literature DB >> 26702301 |
Jan Theopold1, Bastian Marquass1, Nikolaus von Dercks1, Maria Mütze1, Ralf Henkelmann1, Christoph Josten2, Pierre Hepp1.
Abstract
BACKGROUND: Accuracy evaluation of navigated image free placement of double cortical fixation buttons for coracoclavicular tunnel position in comparison to conventional drill guide based placement.Entities:
Keywords: AC joint dislocation; AC joint injuries; AC joint reconstruction; Coracoclavicular; Navigation; Shoulder
Year: 2015 PMID: 26702301 PMCID: PMC4689049 DOI: 10.1186/s13037-015-0087-0
Source DB: PubMed Journal: Patient Saf Surg ISSN: 1754-9493
Fig. 1Clavicular footprint of the trapezoid (t) and conoid (c) ligament, * 20 % ratio of clavicle length. Left shoulder a: anterior, l: lateral; p: posterior; s: sutures for transosseous refixation of deltoid muscle detachment
Fig. 2Arthroscopic subcoracoidal view. a k-wire placement (k) with drill guide (t). b navigated placement with the tip of the pointer (p) placed within den intended region
Fig. 3Virtual control of navigated drilling. a The navigation screen displays the instruments in three different views (front, top and overview) and the autopilot feature with online distance measurement (3) between the tips of instruments after exact instrument alignment; (1) navigated drill sleeve; (2) referenced pointer with the yellow ball representing the tip as target point. b Set up of arthroscopic controlled navigation
Fig. 4Subcoracoid button configuration; a: parallel configuration (left shoulder) b: stepwise configuration with the trapezoid tunnel being 10 mm anterior to the conoid tunnel and 5 mm medial to the lateral border of the coracoid, leaving a bony bridge between tunnels of at least 10 mm (right shoulder) c: non intended mirror-inverted stepwise placement (left shoulder). c: button for conoid tunnel; t: button for trapezoid tunnel
Fig. 5Measurement of the angle between trapezoid and conoid tunnel. a: left shoulder from a patient after drill guide based drilling with parallel tunnel configuration and b right shoulder from a patient after navigated drilling with v-shaped tunnel configuration
Patient data
| Patient no. | Sex | Age | Rockwood Type | Placement | Intended position | Achieved position | K-wire correction (number of) | Concomitant lesions |
|---|---|---|---|---|---|---|---|---|
| 1 | m | 30 | 5 | C | parallel | parallel | 2× | |
| 2 | m | 49 | 4 | C | parallel | m.-i. steplike | - | Pulley type 1 |
| 3 | m | 37 | 5 | C | parallel | parallel | - | Bankart lesion |
| 4 | m | 44 | 3 | C | parallel | parallel | - | |
| 5 | m | 35 | 5 | C | parallel | parallel | 1× | |
| 6 | m | 41 | 5 | C | parallel | parallel | - | SLAP 1 |
| 7 | m | 43 | 5 | C | parallel | parallel | - | SLAP 1 |
| 8 | m | 32 | 5 | C | parallel | steplike | - | |
| 9 | m | 35 | 5 | C | parallel | steplike | - | Labrumlesion, partial tear IST |
| 10 | m | 48 | 4 | C | parallel | 3× | Partial tear SST | |
| 11 | m | 32 | 5 | C | parallel | steplike | - | |
| 12 | m | 46 | 5 | C | parallel | m.i. steplike | - | |
| 13 | f | 27 | 4 | N | parallel | parallel | - | Partial tear SST |
| 14 | m | 27 | 5 | N | parallel | parallel | - | Pulley type 1 |
| 15 | m | 24 | 5 | C | steplike | steplike | 1× | |
| 16 | m | 41 | 5 | N | steplike | steplike | - | Pulley type 1 |
| 17 | m | 51 | 5 | N | steplike | steplike | - | |
| 18 | m | 56 | 3b | N | steplike | steplike | - | |
| 19 | m | 47 | 5 | N | steplike | steplike | - | |
| 20 | m | 21 | 4 | N | steplike | steplike | - | Fracture of the clavicle |
| 21 | m | 41 | 3b | N | steplike | steplike | - | |
| 22 | m | 29 | 5 | N | steplike | steplike | - | |
| 23 | m | 21 | 5 | N | steplike | steplike | - | |
| 24 | m | 35 | 5 | N | steplike | steplike | - | SLAP 2 |
| 25 | m | 54 | 5 | N | steplike | steplike | - | Partial tear SST |
| 26 | m | 40 | 5 | N | steplike | steplike | - |
C drill guide based drilling, N navigated drilling, m.i. mirror-inverted, SST supraspinatus tendon, IST infraspinatus tendon