| Literature DB >> 26695065 |
Mark A Ahlman1, Fabio S Raman2, Scott R Penzak3, Jianing Pang4, Zhaoyang Fan5, Songtao Liu6, Neville Gai7, Debiao Li8, David A Bluemke9.
Abstract
BACKGROUND: The purpose of this study was to define an optimal injection protocol for 5-10 min duration navigator-based coronary MR angiography using an intravascular gadolinium-based contrast agent (GBCA), which is better suited for steady-state coronary MR angiography than conventional GBCAs.Entities:
Mesh:
Substances:
Year: 2015 PMID: 26695065 PMCID: PMC4688989 DOI: 10.1186/s12872-015-0176-0
Source DB: PubMed Journal: BMC Cardiovasc Disord ISSN: 1471-2261 Impact factor: 2.298
Fig. 1Example of axial MOLLI images acquired of the heart. T1 time (in milliseconds) were derived from T1 maps using the MOLLI pulse sequence in the descending aorta (DAo, white arrow) before injection and at subsequent time points after injection. MOLLI – modified Look-Locker inversion recovery, LV left ventricle, RV right ventricle, RA right atrium, DAo descending aorta
Fig. 2Pharmacokinetic model for the intravascular concentration of gadofosveset. Using various dual injection techniques, a fixed percentage of the total volume is injected as the bolus phase, followed by remainder as a slow infusion over a targeted duration to maintain a steady state concentration. A 100 % bolus is also plotted for reference. The 2-compartment model assumes immediate injection and arterial-venous mixing (equilibrium)
Subject demographics
| Demographics | |
| Age (years) | 34.0 ± 7.1 |
| Male n (%) | 5 (36 %) |
| Height (m) | 1.7 ± 0.1 |
| Weight (kg) | 71.9 ± 14.1 |
| Body mass index (kg/m2) | 23.6 ± 2.6 |
| Hematocrit (%) | 44.0 ± 3.3 |
| Creatine (mg/dL) | 0.88 ± 0.17 |
| GFRa (mL/min/1.73 m2) | 104.0 ± 15.3 |
| Heart rate (bpm) | 65.4 ± 3.9 |
| Systolic blood pressure (mmHg) | 118.8 ± 6.8 |
| Diastolic blood pressure (mmHg) | 69.0 ± 9.0 |
| Contrast administration | |
| Dose (mL) | 9.0 ± 2.1 |
aGFR was calculated using the chronic kidney disease epidemiology collaboration (CKD-EPI) formula. Because subjects could be imaged more than once; age, gender, and height were calculated once, whereas other measurements were calculated per imaging visit
GFR glomerular filtration rate
Fig. 3In vivo behavior of dual-injection technique with gadofosveset. Examples of intravascular T1 time with injection protocols in normal volunteers for the (a) 70 %/30 % bolus/infusion, (b) 60 %/40 %, (c) 100 % bolus, and a composite of all subjects imaged (d). Time zero indicates the beginning of infusion