Literature DB >> 21264933

Contrast-enhanced whole-heart coronary MRI with bolus infusion of gadobenate dimeglumine at 1.5 T.

Peng Hu1, Jonathan Chan, Long H Ngo, Jouke Smink, Beth Goddu, Kraig V Kissinger, Lois Goepfert, Thomas H Hauser, Neil M Rofsky, Warren J Manning, Reza Nezafat.   

Abstract

We sought to investigate the T(1) kinetics of blood and myocardium after three infusion schemes of gadobenate dimeglumine (Gd-BOPTA) and subsequently compared contrast-enhanced whole-heart coronary MRI after a bolus Gd-BOPTA infusion with nonenhanced coronary MRI at 1.5 T. Blood and myocardium T(1) was measured in seven healthy adults, after each underwent three Gd-BOPTA infusion schemes (bolus: 0.2 mmol/kg at 2 mL/sec, hybrid: 0.1 mmol/kg at 2 mL/sec followed by 0.1 mmol/kg at 0.1 mL/sec, and slow: 0.2 mmol/kg at 0.3 mL/sec). Fourteen additional subjects underwent contrast-enhanced coronary MRI with an inversion-recovery steady-state free precession sequence after bolus Gd-BOPTA infusion. Images were compared with nonenhanced T(2) -prepared steady-state free precision whole-heart coronary MRI in signal-to-noise ratio, contrast-to-noise ratio, depicted vessel length, vessel sharpness, and subjective image quality. Bolus and slow infusion schemes resulted in similar T(1) during coronary MRI, whereas the hybrid infusion method yielded higher T(1) values. A bolus infusion of Gd-BOPTA significantly improved signal-to-noise ratio, contrast-to-noise ratio, depicted coronary artery length, and subjective image quality, when all segments were collectively compared but not when compared segment by segment. In conclusion, whole-heart steady-state free precision coronary MRI at 1.5 T can benefit from a bolus infusion of 0.2 mmol/kg Gd-BOPTA.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Keywords:  T1 kinetics; contrast-enhanced; gadobenate dimeglumine; whole heart coronary MRI

Mesh:

Substances:

Year:  2010        PMID: 21264933      PMCID: PMC3062103          DOI: 10.1002/mrm.22706

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging.

Authors:  P G Danias; M Stuber; R M Botnar; K V Kissinger; R R Edelman; W J Manning
Journal:  AJR Am J Roentgenol       Date:  1999-04       Impact factor: 3.959

2.  Efficacy of slow infusion of gadolinium contrast agent in three-dimensional MR coronary artery imaging.

Authors:  J Zheng; K T Bae; P K Woodard; E M Haacke; D Li
Journal:  J Magn Reson Imaging       Date:  1999-11       Impact factor: 4.813

3.  Sensitivity encoded cardiac MRI.

Authors:  K P Pruessmann; M Weiger; P Boesiger
Journal:  J Cardiovasc Magn Reson       Date:  2001       Impact factor: 5.364

4.  "Soap-Bubble" visualization and quantitative analysis of 3D coronary magnetic resonance angiograms.

Authors:  Alex Etienne; René M Botnar; Arianne M C Van Muiswinkel; Peter Boesiger; Warren J Manning; Matthias Stuber
Journal:  Magn Reson Med       Date:  2002-10       Impact factor: 4.668

5.  Coronary arteries: contrast-enhanced MR imaging with SH L 643A--experience in 12 volunteers.

Authors:  Christoph U Herborn; Jörg Barkhausen; Ingo Paetsch; Peter Hunold; Marianne Mahler; Kohkan Shamsi; Eike Nagel
Journal:  Radiology       Date:  2003-08-27       Impact factor: 11.105

6.  Coronary magnetic resonance angiography for the detection of coronary stenoses.

Authors:  W Y Kim; P G Danias; M Stuber; S D Flamm; S Plein; E Nagel; S E Langerak; O M Weber; E M Pedersen; M Schmidt; R M Botnar; W J Manning
Journal:  N Engl J Med       Date:  2001-12-27       Impact factor: 91.245

7.  Random-effects models for longitudinal data.

Authors:  N M Laird; J H Ware
Journal:  Biometrics       Date:  1982-12       Impact factor: 2.571

8.  Multislice breath-hold spiral magnetic resonance coronary angiography in patients with coronary artery disease: effect of intravascular contrast medium.

Authors:  Patrick R Knuesel; Daniel Nanz; Ursula Wolfensberger; Manojkumar Saranathan; Anja Lehning; Thomas F Luescher; Borut Marincek; Gustav K von Schulthess; Juerg Schwitter
Journal:  J Magn Reson Imaging       Date:  2002-12       Impact factor: 4.813

9.  Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Authors:  Matthias Stuber; René M Botnar; Stefan E Fischer; Rolf Lamerichs; Jouke Smink; Paul Harvey; Warren J Manning
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

10.  Whole-heart steady-state free precession coronary artery magnetic resonance angiography.

Authors:  Oliver M Weber; Alastair J Martin; Charles B Higgins
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

View more
  13 in total

1.  Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Hussein Rayatzadeh; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

2.  Utility of respiratory-navigator-rejected k-space lines for improved signal-to-noise ratio in three-dimensional cardiac MR.

Authors:  Mehmet Akçakaya; Jaime L Shaw; Thomas H Hauser; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-12-11       Impact factor: 4.668

3.  Subject-specific estimation of respiratory navigator tracking factor for free-breathing cardiovascular MR.

Authors:  Mehdi H Moghari; Peng Hu; Kraig V Kissinger; Beth Goddu; Lois Goepfert; Long Ngo; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

4.  Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

Authors:  Sebastian Weingärtner; Mehmet Akçakaya; Sébastien Roujol; Tamer Basha; Christian Stehning; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02-05       Impact factor: 4.668

5.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

6.  Improved fat water separation with water selective inversion pulse for inversion recovery imaging in cardiac MRI.

Authors:  Lukas Havla; Tamer Basha; Hussein Rayatzadeh; Jaime L Shaw; Warren J Manning; Scott B Reeder; Sebastian Kozerke; Reza Nezafat
Journal:  J Magn Reson Imaging       Date:  2012-08-23       Impact factor: 4.813

7.  Coronary artery angiography and myocardial viability imaging: a 3.0-T contrast-enhanced magnetic resonance coronary artery angiography with Gd-BOPTA.

Authors:  Hong Yun; Hang Jin; Shan Yang; Dong Huang; Zhang-wei Chen; Meng-su Zeng
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-26       Impact factor: 2.357

8.  Improved late gadolinium enhancement MR imaging for patients with implanted cardiac devices.

Authors:  Shams Rashid; Stanislas Rapacchi; Marmar Vaseghi; Roderick Tung; Kalyanam Shivkumar; J Paul Finn; Peng Hu
Journal:  Radiology       Date:  2013-10-28       Impact factor: 11.105

9.  ACCELERATED CORONARY MRI USING 3D SPIRIT-RAKI WITH SPARSITY REGULARIZATION.

Authors:  Seyed Amir Hossein Hosseini; Steen Moeller; Sebastian Weingärtner; Kȃmil Uǧurbil; Mehmet Akçakaya
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2019-07-11

10.  Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing.

Authors:  Sébastien Roujol; Murilo Foppa; Tamer A Basha; Mehmet Akçakaya; Kraig V Kissinger; Beth Goddu; Sophie Berg; Reza Nezafat
Journal:  J Cardiovasc Magn Reson       Date:  2014-11-22       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.