Literature DB >> 26674192

Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.

Paul S Gunning1, Neelakantan Saikrishnan2, Ajit P Yoganathan2, Laoise M McNamara3.   

Abstract

Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a 'peel-back' leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve.
© 2015 The Author(s).

Entities:  

Keywords:  distortion; eccentric; leaflets; self-expanding; stent; transcatheter aortic valve replacement

Mesh:

Year:  2015        PMID: 26674192      PMCID: PMC4707849          DOI: 10.1098/rsif.2015.0737

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  39 in total

1.  Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy.

Authors:  Ashraf Hamdan; Victor Guetta; Eli Konen; Orly Goitein; Amit Segev; Ehud Raanani; Dan Spiegelstein; Ilan Hay; Elio Di Segni; Michael Eldar; Ehud Schwammenthal
Journal:  J Am Coll Cardiol       Date:  2012-01-10       Impact factor: 24.094

2.  The effects of a three-dimensional, saddle-shaped annulus on anterior and posterior leaflet stretch and regurgitation of the tricuspid valve.

Authors:  Erin M Spinner; Dana Buice; Choon Hwai Yap; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2011-12-01       Impact factor: 3.934

3.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.

Authors:  Wei Sun; Kewei Li; Eric Sirois
Journal:  J Biomech       Date:  2010-12-01       Impact factor: 2.712

4.  Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.

Authors:  A N Smuts; D C Blaine; C Scheffer; H Weich; A F Doubell; K H Dellimore
Journal:  J Mech Behav Biomed Mater       Date:  2010-09-29

5.  Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography.

Authors:  Alexander B Willson; John G Webb; Ronen Gurvitch; David A Wood; Stefan Toggweiler; Ronald Binder; Melanie Freeman; Mark Madden; Cameron Hague; Jonathon Leipsic
Journal:  JACC Cardiovasc Interv       Date:  2012-05       Impact factor: 11.195

6.  In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prostheses.

Authors:  Maximilian Kuetting; Alexander Sedaghat; Marc Utzenrath; Jan-Malte Sinning; Christoph Schmitz; Jan Roggenkamp; Nikos Werner; Thomas Schmitz-Rode; Ulrich Steinseifer
Journal:  J Biomech       Date:  2014-01-21       Impact factor: 2.712

Review 7.  Transcatheter aortic valve implantation: current and future approaches.

Authors:  Josep Rodés-Cabau
Journal:  Nat Rev Cardiol       Date:  2011-11-15       Impact factor: 32.419

8.  Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties.

Authors:  Caitlin Martin; Wei Sun
Journal:  Biomech Model Mechanobiol       Date:  2013-10-04

9.  Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis.

Authors:  Marie-Annick Clavel; John G Webb; Philippe Pibarot; Lukas Altwegg; Eric Dumont; Chris Thompson; Robert De Larochellière; Daniel Doyle; Jean-Bernard Masson; Sebastien Bergeron; Olivier F Bertrand; Josep Rodés-Cabau
Journal:  J Am Coll Cardiol       Date:  2009-05-19       Impact factor: 24.094

Review 10.  Role of arterial stiffness in cardiovascular disease.

Authors:  Marina Cecelja; Phil Chowienczyk
Journal:  JRSM Cardiovasc Dis       Date:  2012-07-31
View more
  12 in total

1.  In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.

Authors:  Megan Heitkemper; Hoda Hatoum; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2019-06-19

2.  Realistic Vascular Replicator for TAVR Procedures.

Authors:  Oren M Rotman; Brandon Kovarovic; Chander Sadasivan; Luis Gruberg; Baruch B Lieber; Danny Bluestein
Journal:  Cardiovasc Eng Technol       Date:  2018-04-13       Impact factor: 2.495

3.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Authors:  Caitlin Martin; Wei Sun
Journal:  Ann Biomed Eng       Date:  2016-10-12       Impact factor: 3.934

4.  Bovine Pericardium of High Fibre Dispersion Has High Fatigue Life and Increased Collagen Content; Potentially an Untapped Source of Heart Valve Leaflet Tissue.

Authors:  Alix Whelan; Elizabeth Williams; David R Nolan; Bruce Murphy; Paul S Gunning; David O'Reilly; Caitríona Lally
Journal:  Ann Biomed Eng       Date:  2020-10-15       Impact factor: 3.934

Review 5.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

6.  Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

Authors:  Hoda Hatoum; Shelley Gooden; Megan Heitkemper; Kevin M Blum; Jason Zakko; Martin Bocks; Tai Yi; Yen-Lin Wu; Yadong Wang; Christopher K Breuer; Lakshmi Prasad Dasi
Journal:  Ann Biomed Eng       Date:  2020-02-12       Impact factor: 3.934

7.  Stented valve dynamic behavior induced by polyester fiber leaflet material in transcatheter aortic valve devices.

Authors:  Hoda Hatoum; Frederick Heim; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2018-06-28

Review 8.  Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization.

Authors:  Tian-Yuan Xiong; Walid Ben Ali; Yuan Feng; Kentaro Hayashida; Hasan Jilaihawi; Azeem Latib; Michael Kang-Yin Lee; Martin B Leon; Raj R Makkar; Thomas Modine; Christoph Naber; Yong Peng; Nicolo Piazza; Michael J Reardon; Simon Redwood; Ashok Seth; Lars Sondergaard; Edgar Tay; Didier Tchetche; Wei-Hsian Yin; Mao Chen; Bernard Prendergast; Darren Mylotte
Journal:  Nat Rev Cardiol       Date:  2022-06-20       Impact factor: 32.419

9.  An in vitro evaluation of turbulence after transcatheter aortic valve implantation.

Authors:  Hoda Hatoum; Atieh Yousefi; Scott Lilly; Pablo Maureira; Juan Crestanello; Lakshmi P Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-02       Impact factor: 5.209

10.  The hemodynamics of transcatheter aortic valves in transcatheter aortic valves.

Authors:  Hoda Hatoum; Scott Lilly; Pablo Maureira; Juan Crestanello; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2019-10-30       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.