Literature DB >> 22130636

The effects of a three-dimensional, saddle-shaped annulus on anterior and posterior leaflet stretch and regurgitation of the tricuspid valve.

Erin M Spinner1, Dana Buice, Choon Hwai Yap, Ajit P Yoganathan.   

Abstract

Tricuspid regurgitation (TR) is present in trace amounts or more in 82-86% of the population and is greater than mild in 14% of the population. In severe cases, it can contribute to right heart failure and adversely affect mitral valve repair durability. One major cause of TR is the dilation of the tricuspid annulus, which alters the geometry of the annulus from a saddle-shape to a more planar profile. Another cause of TR is the displacement of the papillary muscles (PMs), which results from right ventricular dilation. The objective of this study was to identify the effect of a saddle-shaped annulus on native tricuspid leaflet stretch mechanics and TR. In addition, the effects of geometric alterations, including annular dilatation and PM displacement, on leaflet stretch was investigated. Fresh porcine tricuspid valves (TVs) (n = 8) were excised and sutured to an adjustable three-dimensional annulus plate (allowing for dilatation and saddle-shape) and three PM attachment rods. The valve was then placed in the in vitro Georgia Tech right heart simulator. Dual-camera photogrammetry, was used to quantify the stretch ratio experienced by the valve leaflets at peak systole for the following conditions: physiologically normal, 100% annular dilatation, displaced PMs, and a combination of annular dilatation and PM displacement. In addition, a saddle and flat annulus were implemented for each of the four conditions. PM displacement was simulated by displacing all PMs by 10 mm in all directions (laterally, apically, posteriorly/anteriorly). The physiologically normal condition-normal annulus area, saddle-shaped annulus with PMs in a normal position, was used as a control. The results showed that the posterior leaflet exhibited significantly (p ≤ 0.05) higher major and areal stretch ratios as compared to the anterior leaflet at peak systole for all conditions tested. No significant difference was seen in stretch when a flat annulus was compared to saddle for the anterior or posterior leaflet for normal or disease conditions. Investigation of the impact of disease found a significant increase (p ≤ 0.10) in stretch in the posterior leaflet with a combination of annular dilatation and PM displacement (2.01 ± 0.68) as compared to the normal condition with a saddle annulus (1.43 ± 0.20). In addition displacement of the PMs resulted in a significant (p ≤ 0.01) reduction in TR, although the actual volume reduced was minimal (1.2 mL). Stretch values were measured for the anterior and posterior leaflet under both physiologic and pathologic conditions for the first time. Further, these results provide an understanding of the effects of geometric parameters on valve mechanics and function, which may lead to improved TV repairs.

Entities:  

Mesh:

Year:  2011        PMID: 22130636     DOI: 10.1007/s10439-011-0471-6

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  8 in total

1.  Current transcatheter devices to treat functional tricuspid regurgitation with discussion of issues relevant to clinical trial design.

Authors:  Rebecca T Hahn
Journal:  Ann Cardiothorac Surg       Date:  2017-05

Review 2.  Cardiac Computed Tomography (CT) Evaluation of Valvular Heart Disease in Transcatheter Interventions.

Authors:  Marcelo Godoy; Ahmed Mugharbil; Malcom Anastasius; Jonathon Leipsic
Journal:  Curr Cardiol Rep       Date:  2019-11-25       Impact factor: 2.931

3.  Comprehensive Two-Dimensional Interrogation of the Tricuspid Valve Using Knowledge Derived from Three-Dimensional Echocardiography.

Authors:  Karima Addetia; Megan Yamat; Anuj Mediratta; Diego Medvedofsky; Mita Patel; Preston Ferrara; Victor Mor-Avi; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2015-09-28       Impact factor: 5.251

4.  Finite Element Analysis of Tricuspid Valve Deformation from Multi-slice Computed Tomography Images.

Authors:  Fanwei Kong; Thuy Pham; Caitlin Martin; Raymond McKay; Charles Primiano; Sabet Hashim; Susheel Kodali; Wei Sun
Journal:  Ann Biomed Eng       Date:  2018-04-16       Impact factor: 3.934

5.  Tricuspid annular geometry: a three-dimensional transesophageal echocardiographic study.

Authors:  Feroze Mahmood; Han Kim; Bilal Chaudary; Remco Bergman; Robina Matyal; Jeniffer Gerstle; Joseph H Gorman; Robert C Gorman; Kamal R Khabbaz
Journal:  J Cardiothorac Vasc Anesth       Date:  2013-05-30       Impact factor: 2.628

6.  Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.

Authors:  Paul S Gunning; Neelakantan Saikrishnan; Ajit P Yoganathan; Laoise M McNamara
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

Review 7.  Mechanics of the Tricuspid Valve-From Clinical Diagnosis/Treatment, In-Vivo and In-Vitro Investigations, to Patient-Specific Biomechanical Modeling.

Authors:  Chung-Hao Lee; Devin W Laurence; Colton J Ross; Katherine E Kramer; Anju R Babu; Emily L Johnson; Ming-Chen Hsu; Ankush Aggarwal; Arshid Mir; Harold M Burkhart; Rheal A Towner; Ryan Baumwart; Yi Wu
Journal:  Bioengineering (Basel)       Date:  2019-05-22

Review 8.  Heart Valve Biomechanics: The Frontiers of Modeling Modalities and the Expansive Capabilities of Ex Vivo Heart Simulation.

Authors:  Matthew H Park; Yuanjia Zhu; Annabel M Imbrie-Moore; Hanjay Wang; Mateo Marin-Cuartas; Michael J Paulsen; Y Joseph Woo
Journal:  Front Cardiovasc Med       Date:  2021-07-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.