Comparison of Diagnostic Ability of Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurement by Stereomicroscope: A Pilot Study.

Velayudhannair Vivek1, Sunila Thomas1, Bindu J Nair1, Alex Daniel Vineet1, Jincy Thomas1, Prasanna Ranimol1, Aswathy K Vijayan1.   

Abstract

Radiography plays an important role in detection of interproximal caries. The aim of study is to compare diagnostic ability of photo stimulable phosphor (PSP) with direct measurement using stereomicroscope in detecting proximal caries. Hundred proximal surfaces of 50 extracted human posterior teeth were radiographed with dental X-ray unit. The image receptors used was storage phosphor plate Vista scan (size 2), (time of exposure 0.4 s). Radiographs were interpreted and caries lesions were classified on a 4-point scale suggested by Abesi et al. The teeth were sectioned with diamond disc and were examined under a stereomicroscope with 20x magnification. Diagnostic accuracy of digital image is similar to that observed with stereomicroscope. The PSP plate digital X ray system can effectively be employed for detecting proximal caries as compared to direct observation by stereomicro-scope. Further study with more number of observer/evaluator and large sample size is recommended.

Entities:  

Keywords:  Proximal caries; intra oral radiography; sensitivity; stereomicroscope; storage phosphor plate

Year:  2015        PMID: 26664712      PMCID: PMC4653748          DOI: 10.4081/cp.2015.763

Source DB:  PubMed          Journal:  Clin Pract        ISSN: 2039-7275


Introduction

Diagnosis of caries is mostly based on direct visual examination and intra oral radiography.[1,2] Intra oral radiography is an established technique for diagnosis of caries especially non cavitated proximal lesions.[1,2] If diagnosed early the non cavitated proximal lesions can be managed with minimal intervention.[3,4] The introduction of digital radiographic systems has reduced radiation doses as these digital sensors are more sensitive to radiation than film[1,2].The detecting ability of charged coupled device (CCD) and complementary metal oxide semiconductor (CMOS) based digital radiographic systems were compared by several authors and observed that the two modalities are comparable in detecting caries.[1,2] CCD is now days not so common in the sensor technique. The CMOS technique is the major system by the majority of vendors. CMOS require less system power, longer life span, cheaper &easier to manufacture.[5] CMOS and photo stimulable phosphor (PSP) (storage phosphor plates) are the system currently in use for digital imaging. Storage phosphor plates has the advantage of being similar in size to conventional film there by enabling easy and similar positioning with position indicating device.[6] Studies on capability of storage phosphor plates over conventional films in detecting proximal caries are not in plenty.[6] Stereomicroscopy allows a three dimensional view of teeth in a large examination field which is useful to appreciate the depth and width of progressing carious process.[7] This study was conducted to compare diagnostic ability of storage phosphor plates with gold standard direct measurements of teeth sections with stereomicroscope in detecting proximal caries.

Materials and Methods

The study was carried out on 50 extracted human posterior teeth (100 dental surfaces) out of which 46 were carious teeth. The teeth were visually inspected for the presence or absence of caries on proximal surfaces. Exclusion criteria included those with extensive buccal or lingual caries and presence of fracture or anomalies. These teeth numbered serially from no. 1 to 100 (Figure 1A) were embedded in plaster of Paris from apex to cementoenamel junction, with their approximal surfaces in contact. The teeth were radiographed under standardized condition with GNATUS dental radiographic unit (RAIOS X TIMEX 70C) 70 kVp, and 7mA. The image receptor used was 1 durrdental storage phosphor plate (size 2) at 0.4 s (Figure 1B). The exposed phosphor plates were scanned in the Vista scanner (Figure 1C).
Figure 1.

A) Teeth serially numbered; B) Storage phosphor plate; C) Photo stimulable phosphor images of block with embedded teeth and values.

Radiographic evaluation

Digital images were examined by a MDS qualified examiner with a 14-year experience. Digital images were viewed on a 15-inch monitor (view sonic) with a resolution of 1366×768 in a well-illuminated room. Radiographs were interpreted and carious lesion were classified based on a 4 point scale (Table 1) ranging from R0 to R3.[8]
Table 1.

Scale for assessing caries depth on a 4 point scale from R0 to R3.

PointDescription
R0Sound surface
R1Caries restricted to enamel
R2Caries reaching dentino-enamel junction and outer half of dentin
R3Caries reaching inner half of dentin

Histological examination

Direct measurement using stereomicroscope was considered as gold standard of assessment of proximal caries. The previously radiographed teeth were sectioned using a diamond disc mounted in a low speed saw in a mesio-distal direction adjacent to approximal lesions (Figure 2). The sections were subsequently examined under a stereomicroscope with 20x magnification. The caries lesions were classified based on a 4-point scale[8] ranging from R0-R3 by a qualified oral pathologist with 22 years of experience (Figure 3).
Figure 2.

Sectioned teeth.

Figure 3.

A) Stereomicroscopic section showing caries reaching inner half of dentin R3; B) Stereomicroscopic section showing sound surface R0.

Statistical analysis

Analysis was performed to detect all lesions in approximal surfaces in which scale R0[8] in the stereomicroscope was considered as negative and scale R1,R2 and R3[8] in the stereomicroscope were considered as positive. True negative, true positive, false negative and false positive values were calculated from these so that sensitivity, specificity, accuracy, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio was calculated (Table 2). ROC analysis done and the area under the curve for PSP were found to be 0.850 with a standard error of 0.039 (Figure 4).
Table 2.

Comparison of result in photo stimulable phosphor and stereomicroscope.

ResultTotal number of teeth surfacesPSPStereomicroscope
R0844242
R1281216
R21477
R3693435

PSP, photo stimulable phosphor.

Figure 4.

ROC curve.

Results

Radiographic images captured in PSP plate were evaluated and the results were tabulated along with that obtained from stereomicroscopic readings of the same teeth. PSP evaluation of 100 dental surfaces showed that 42 surfaces were noncarious (R0), 12 surfaces confined to enamel (R1), 7 surfaces extended into dentino-enamel junction and outer half of dentin (R2) and 34 surfaces into inner half of dentin (R3). Histological examination of 100 dental surfaces showed that 42 surfaces were noncarious (R0), 16 surfaces confined to enamel (R1), 7 surfaces extended into dentino enamel junction and outer half of dentin (R2) and 35 surfaces into the inner half of dentin (R3). Comparison of results of PSP plate and stereomicroscope observation of 100 surfaces (50 mesial and 50 distal) revealed that the values were comparable in 78 surfaces, showing that diagnostic accuracy of PSP images are equally good in detecting proximal caries as direct measurements using stereomicroscope which is the gold standard. Results obtained are summarized in Table 3.
Table 3.

Results showing measures of accuracy for all proximal caries.

Indices of diagnostic test accuracyResults
Sensitivity80.7%
Specificity74.4%
Positive predictive value80.7%
Negative predictive value74.41%
Accuracy78%
Positive likelihood ratio3.15
Negative likelihood ratio0.256

Discussion

In this in vitro study we compared PSP images of proximal caries with direct measurement using stereomicroscope, which was considered as gold standard in detecting proximal caries. Visual examination was done prior to radiographic and histological examination. Visual examination has the disadvantage of missing hidden caries which is large and demineralized enough to be detected by radiographic and microscopic examination.[9] Stereomicroscopy allows a three dimensional view of teeth in a large examination field which is useful to appreciate the depth and width of progressing carious process.[7] The microscopic observations were evaluated based on the four point scale.[8] The analysis was performed to detect all lesions in proximal caries. In the present study major samples were having deeper lesions that confined to inner half of dentin (Table 3). The sensitivity of storage phosphor plate in detecting proximal caries in our study, which compared PSP and stereomicroscope, was 80.7% meaning that system was effective in detecting all proximal lesions. In this study where we compared PSP images with direct measurements using stereomicroscope which is the gold standard in detecting proximal caries we found that the diagnostic accuracy of PSP were comparable with that of stereomicroscope. In detecting approximal caries the diagnostic accuracy of X-ray films, CCD based digital systems and phosphor plates based digital systems with gold standard stereomicroscope were compared by Syriopoulos et al. and revealed that there was no difference in the capability of the studied systems.[1] Castro et al. in 2007 compared the diagnostic accuracy of conventional film and CMOS (complementary metal oxide semiconductor) with gold standard stereomicroscope and found the two modalities were comparable.[2] The author discussed that 40% demineralization of hard tissue is required before lesions are identified on radiographs. The present study was in accordance with Castro et al. and Syriopoulos et al. which revealed that deeper caries lesions were easier to detect by radiographic modalities rather than superficial ones. In a comparative study by Abesi et al., authors reported a low range of sensitivity 15-38% for enamel caries and a sensitivity of 55-65% for all proximal lesions in their study comparing the diagnostic accuracy of charged couple devices, PSP, and film radiography with gold standard stereomicroscope in detection of proximal caries.[8] The authors demonstrated that detecting ability of the three radiographic modalities improved more with depth of lesions. Pontual et al., Hintze et al. and Farmen et al. found that both PSP and conventional film have low sensitivity (14 to 16%) in detecting enamel approximal caries in a study comparing these radiographic modalities with gold standard histological measurements using stereomicroscope.[10-12] The authors were of opinion that the low sensitivity suggests failure of radiographic modalities to detect enamel approximal caries efficiently. In a comparative study by Haiter Neto et al. using older and newer versions of PSP and CMOS with gold standard stereomicroscope the authors found a low sensitivity ranging from 15 to 23% in detecting small initial lesions.[13] This finding is in accordance with the results of earlier studies of detection of proximal lesions by Hintze et al.[14] In our study the sensitivity of 80.7% could be explained by the depth of caries lesions as majority of the teeth studied had R3 lesions.[1,2] In a study by Versteej et al. he was of opinion that conventional film was better than PSP in detecting proximal caries.[15] Huda et al. observed that PSP was better than conventional film in detecting approximal caries,[16] inspite of conventional film having more spatial resolution. However in both these studies comparison were made based on function of radiation exposure and not stereomicroscope. Pontual et al., Hintze et al. and Farmen et al. found that both PSP and conventional film have low sensitivity in detecting enamel approximal caries in a study comparing these radiographic modalities with gold standard histological measurements using stereomicroscope.[10-12] This low sensitivity suggests that radiographic modalities failed to detect enamel approximal caries. In a comparative study by Haiter Neto et al. using older and newer versions of PSP and CMOS with gold standard stereomicroscope the authors reported a low sensitivity in detecting small initial lesions.[11] This finding is in accordance with the results of earlier studies of detection of proximal lesions by Hintze et al.[14] who compared conventional film, Radiovisiography and PSP systems with gold standard stereomicroscope. Zhang et al. 2011 compared the accuracy of cone beam computed tomography (CBCT), conventional film and storage phosphor plates in detection of non cavitated proximal caries and found that the accuracy of CBCT in non cavitated proximal caries was similar to that with phosphor plate and film based intra oral images.[6] The present study is limited by the fact that it was a single observer study where X rays were examined by a single observer and subsequently the stereomicroscope was also examined by a single observer. The sample size was small and most of the samples were having R3 lesions.

Conclusions

In the present study the result of proximal caries obtained from PSP images were comparable with that of direct measurements using stereomicroscope, which was considered as the gold standard. This showed that digital radiographic method using PSP was equally good as stereomicroscope in detecting proximal caries. In our study most of the studied sample was R3 lesions. However keeping in view the limitation of our studies further study with more number of observer/evaluator and large sample size may probably establish our results.
  14 in total

1.  Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems.

Authors:  H Hintze; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2002-01       Impact factor: 2.419

2.  Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems.

Authors:  K Syriopoulos; G C Sanderink; X L Velders; P F van der Stelt
Journal:  Dentomaxillofac Radiol       Date:  2000-09       Impact factor: 2.419

3.  Comparison of digital systems and conventional dental film for the detection of approximal enamel caries.

Authors:  A A Pontual; D P de Melo; S M de Almeida; F N Bóscolo; F Haiter Neto
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

4.  The detection accuracies for proximal caries by cone-beam computerized tomography, film, and phosphor plates.

Authors:  Zhi-ling Zhang; Xing-min Qu; Gang Li; Zu-yan Zhang; Xu-chen Ma
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-10-16

5.  Reliability of Logicon caries detector in the detection and depth assessment of dental caries: an in-vitro study.

Authors:  Rohit R Behere; Shailesh M Lele
Journal:  Indian J Dent Res       Date:  2011 Mar-Apr

6.  In vivo study of approximal caries depth on storage phosphor plate images compared with dental x-ray film.

Authors:  K H Versteeg; G C Sanderink; X L Velders; F C van Ginkel; P F van der Stelt
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1997-08

7.  Detection of cavitated or non-cavitated approximal enamel caries lesions using CMOS and CCD digital X-ray sensors and conventional D and F-speed films at different exposure conditions.

Authors:  Peter Bottenberg; Wolfgang Jacquet; Vitus Stachniss; Johann Wellnitz; Andreas G Schulte
Journal:  Am J Dent       Date:  2011-04       Impact factor: 1.522

8.  A comparison of older and newer versions of intraoral digital radiography systems: diagnosing noncavitated proximal carious lesions.

Authors:  Francisco Haiter-Neto; Andrea dos Anjos Pontual; Morten Frydenberg; Ann Wenzel
Journal:  J Am Dent Assoc       Date:  2007-10       Impact factor: 3.634

9.  In vitro comparison of D- and E-speed film radiography, RVG, and visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions.

Authors:  H Hintze; A Wenzel; C Jones
Journal:  Caries Res       Date:  1994       Impact factor: 4.056

10.  Diagnostic accuracy of digital and conventional radiography in the detection of non-cavitated approximal dental caries.

Authors:  Farida Abesi; Alireza Mirshekar; Ehsan Moudi; Maryam Seyedmajidi; Sina Haghanifar; Nima Haghighat; Ali Bijani
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

View more
  2 in total

Review 1.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

Review 2.  Systematic review and meta-analysis of diagnostic studies of proximal surface caries.

Authors:  Mila Janjic Rankovic; Svetlana Kapor; Yegane Khazaei; Alexander Crispin; Ina Schüler; Felix Krause; Kim Ekstrand; Stavroula Michou; Florin Eggmann; Adrian Lussi; Marie-Charlotte Huysmans; Klaus Neuhaus; Jan Kühnisch
Journal:  Clin Oral Investig       Date:  2021-09-04       Impact factor: 3.573

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.