Literature DB >> 10710463

Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions.

S B Paurazas1, J R Geist, F E Pink, M M Hoen, H R Steiman.   

Abstract

OBJECTIVE: The purpose of this study was to compare E-speed Plus film and digital imaging with a charge-coupled device (CCD) sensor and a complementary metal-oxide semiconductor active pixel sensor (CMOS-APS) in the detection of periapical bone lesions. STUDY
DESIGN: Periapical lesions were created in the cortical and trabecular bone of 10 dried human mandibles. Seventy radio-graphic images and 140 digital images were evaluated by 6 endodontists and 2 radiologists. Receiver operating characteristics curves and analysis of variance were used for statistical analysis.Results. No statistically significant differences were found between film, CCD, and CMOS-APS systems. Lesion detection occurred with significantly greater accuracy in cortical bone than in trabecular bone, as well as when the cortical plate was involved.
CONCLUSIONS: That no differences were found between the two sensors lends support for the use of CMOS-APS sensors, which require less system power and may have longer life spans than CCD sensors. Digital imaging required 50% less radiation than film to obtain the same diagnostic information.

Entities:  

Mesh:

Year:  2000        PMID: 10710463     DOI: 10.1016/s1079-2104(00)70102-8

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  18 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

Review 3.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

4.  A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate.

Authors:  A Anas; Jm Asaad; Ka Tarboush
Journal:  Int J Health Sci (Qassim)       Date:  2010-11

5.  A comparative study on diagnostic accuracy of colour coded digital images, direct digital images and conventional radiographs for periapical lesions - an in vitro study.

Authors:  Abhishek Ranjan Pati; Vijayalakshmi K R; Sanat Kumar Bhuyan; Rajat G Panigrahi; Smita R Priyadarshini; Satyaranjan Misra; Chandravir Singh
Journal:  J Clin Diagn Res       Date:  2014-11-20

6.  Comparison of diagnostic accuracy of conventional intraoral periapical and direct digital radiographs in detecting interdental bone loss.

Authors:  S R Ashwinirani; Girish Suragimath; H P Jaishankar; Prasad Kulkarni; Shobha C Bijjaragi; Varsha Ajit Sangle
Journal:  J Clin Diagn Res       Date:  2015-02-01

7.  Different digital imaging techniques in dental practice.

Authors:  Amela Lacević; Edina Vranić
Journal:  Bosn J Basic Med Sci       Date:  2004-05       Impact factor: 3.363

8.  The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.

Authors:  Kristina Hellén-Halme; Mats Nilsson
Journal:  J Oral Maxillofac Res       Date:  2013-10-01

9.  A comparative study on image quality of two digital intraoral sensors.

Authors:  Cinar Aziman; Kristina Hellén-Halme; Xie-Qi Shi
Journal:  Dentomaxillofac Radiol       Date:  2019-05-14       Impact factor: 2.419

10.  Conventional versus digital radiographs in detecting artificial voids in root canal filling material.

Authors:  Mohammad Mahdi Aghdasi; Mohammad Asnaashari; Alireza Aliari; Farahnaz Fahimipour; Sepideh Soheilifar
Journal:  Iran Endod J       Date:  2011-08-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.