| Literature DB >> 34480645 |
Mila Janjic Rankovic1, Svetlana Kapor2, Yegane Khazaei2,3, Alexander Crispin3, Ina Schüler4, Felix Krause5, Kim Ekstrand6, Stavroula Michou6, Florin Eggmann7, Adrian Lussi8,9, Marie-Charlotte Huysmans10, Klaus Neuhaus7,11, Jan Kühnisch12,13.
Abstract
AIM: This systematic review and meta-analysis aimed to assess the diagnostic accuracy and reliability of commonly used caries detection methods for proximal caries diagnostics. Visual examination (VE), bitewing radiography (BWR), laser fluorescence (LF), and fibre-optic transillumination (FOTI) were considered in detail.Entities:
Keywords: Approximal caries; Bitewing radiography; Caries detection; Caries diagnostics; Diagnostic accuracy; Diagnostic performance; Fibre-optic transillumination; Interproximal caries; Laser fluorescence measurements; Meta-analysis; Proximal caries; Sensitivity; Specificity; Systematic review; Visual examination
Mesh:
Year: 2021 PMID: 34480645 PMCID: PMC8531083 DOI: 10.1007/s00784-021-04113-1
Source DB: PubMed Journal: Clin Oral Investig ISSN: 1432-6981 Impact factor: 3.573
Search strategy and documentation of keywords according to the PIRDS concept [27]
| Population/Problem ( | Index test ( | Reference test ( | Diagnostic and study type ( | |||
|---|---|---|---|---|---|---|
caries decay AND proximal approximal interdental | AND | visual clinical* inspect* ICDAS bitewing conventional digital film radiogra* analo* speed* X ray Xray radiol* roentge* laser fluorescence diagnodent foti difoti fiber fibre transillumination opti* qlf quantit* laser light induced | AND | valid* accuracy sensitivity specificity SE SP ROC Az reproducib* reliab* Kappa threshold cut-off performance histolog* micro micro computed CT *CT | AND | Systemat* Meta-Analysis Diagnos* Detect* Assessm* Vivo Vitro Study Studies |
MeSH terms that were used to search the PubMed and EMBASE databases: ((caries OR decay) AND (proximal OR approximal OR interdental) AND (visual OR clinical* OR inspect* OR icdas OR bitewing OR conventional OR digital OR film OR radiogra* OR analo* OR speed* OR X ray OR Xray OR radiol* OR roentge* OR laser OR fluorescence OR diagnodent OR foti OR difoti OR fiber OR fibre OR transillumination OR opti* OR qlf OR quantit* OR laser OR light OR induced) AND (OR valid* OR accuracy OR sensitivity OR specificity OR se OR sp OR roc OR az OR reproducib* OR reliab* OR kappa OR threshold OR cutoff OR perfORmance OR histolog* OR micro OR micro computed OR ct OR *ct) AND (systemat* OR review OR meta-analysis OR diagnos* OR detect* OR assessm* OR vivo OR vitro OR study OR studies)) | ||||||
Fig. 1Flow diagram detailing our search and study selection process applied during the systematic literature search (1st step) and study quality assessment (2nd step)
Overview of the identified diagnostic studies in relation to the method used and characteristics of the study setup with stepwise included studies for meta-analysis
| Studies on diagnostic methods | 1st step | 2nd step | |||
|---|---|---|---|---|---|
| Study inclusion according to the systematic search of the literature | Study inclusion according to the quality assessment | ||||
| Study setup | Specification ( | Low/moderate RoB | Acceptable index and reference test | Acceptable data reporting quality | |
| VE ( | In vitro ( | 10 | 10 | 10 | |
| In vivo ( | 2 | 2 | 2 | ||
| Conventional bitewing radiography ( | In vitro ( | D-speed ( | 24 | 24 | 19 |
| E-speed ( | |||||
| F-speed ( | |||||
| Not specified ( | |||||
| In vivo ( | D-speed ( | ||||
| E-speed ( | 1 | 1 | 1 | ||
| F-speed ( | |||||
| Digital bitewing radiography ( | In vitro ( | Phosphor plate ( | 23 | 23 | 19 |
| Sensor ( | |||||
| In vivo ( | Phosphor plate ( | 4 | 4 | 3 | |
| Sensor ( | |||||
| LF measurement ( | In vitro ( | DIAGNOdent 2095 ( | 5 | 5 | 4 |
| DIAGNOdent 2190/pen ( | |||||
| In vivo ( | DIAGNOdent 2095 ( | 4 | 4 | 4 | |
| DIAGNOdent 2190/pen ( | |||||
| Fibre-optic transillumination ( | In vitro ( | - | - | - | |
| In vivo ( | - | - | - | ||
Fig. 2RoB graph across included in vivo (a) and in vitro (b) caries diagnostic studies for proximal surfaces. *Item no. 1 (patient selection bias) is only available for clinical diagnostic studies
Bivariate diagnostic random-effects meta-analysis for the finally included in vitro and in vivo studies for all diagnostic methods at different caries detection levels
| Method and parameters | Caries detection level | Dentin detection level | 1/3 dentin detection level | |||
|---|---|---|---|---|---|---|
| In vitro | In vivo | In vitro | In vivo | In vitro | ||
| Visual examination | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 9 0.64 (0.42–0.81) 0.85 (0.74–0.92) 11.49 (5.19–25.46) 0.84 | - | 1 0.09 (0.04–0.24) 0.99 (0.94–0.999) 13.26 (1.44–122.51) 0.85 | 2 0.32 (0.07–0.74) 0.76 (0.11–0.99) 1.84 (0.03–103.47) 0.53 | 1 0.93 (0.77–0.98) 0.84 (0.76–0.89) 67.0 (14.7–304.9) 0.95 |
| Conventional bitewing radiography (D-speed) | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 2 0.19 (0.13–0.28) 0.96 (0.91–0.99) 5.2 (1.6–16.8) 0.55 | - | 1 0.17 (0.07–0.40) 0.99 (0.96–0.999) 31.0 (3.3–291.3) 0.91 | - | - |
| Conventional bitewing radiography (E-speed) | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 9 0.42 (0.28–0.57) 0.90 (0.84–0.93) 6.80 (4.58–10.10) 0.82 | - | 5 0.67 (0.19–0.95) 0.94 (0.71–0.99) 31.40 (14.31–68.93) 0.92 | 1 0.35 (0.19–0.51) 0.91 (0.80–0.96) 4.8 (1.48–15.48) 0.74 | - |
| Conventional bitewing radiography (F-speed) | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 8 0.43 (0.31–0.57) 0.88 (0.74–0.95) 5.34 (2.55–11.17) 0.72 | - | 3 0.42 (0.29–0.56) 0.92 (0.86–0.96) 8.7 (4.2–18.1) 0.81 | - | 1 0.54 (0.36–0.70) 0.996 (0.96–1) 283.6 (16.1–5010.0) 0.98 |
| Digital bitewing radiography (sensor) | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 12 0.35 (0.26–0.45) 0.90 (0.85–0.93) 5.01 (2.83–8.88) 0.74 | 1 0.55 (0.42–0.67) 0.93 (0.77–0.98) 17.11 (3.73–78.39) 0.82 | 4 0.36 (0.30–0.42) 0.95 (0.93–0.97) 12.84 (6.56–25.13) 0.90 | 1 0.96 (0.91–0.98) 0.50 (0.02–0.98) 24.4 (0.44–1359.98) 0.89 | - |
| Digital bitewing radiography (phosphor plate) | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 11 0.41 (0.25–0.61) 0.89 (0.83–0.93) 5.56 (3.04–10.16) 0.82 | - | 2 0.86 (0.03–0.99) 0.86 (0.11–0.99) 26.06 (7.29–93.21) 0.92 | 1 0.83 (0.77–0.88) 0.60 (0.20–0.90) 7.5 (1.19–47.13) 0.79 | - |
| Laser fluorescence 2190 | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | 5 0.79 (0.62–0.90) 0.89 (0.76–0.95) 30.79 (8.74–108.51) 0.91 | 1 0.92 (0.82–0.96) 0.90 (0.73–0.97) 99 (22.01–445.30) 0.96 | 5 0.82 (0.58–0.94) 0.81 (0.78–0.85) 23.09 (7.01–76.04) 0.83 | 3 0.63 (0.58–0.68) 0.60 (0.15–0.93) 2.18 (0.24–19.95) 0.63 | - |
| Fibre-optic transillumination FOTI | SE (95% CI) SP (95% CI) DOR (95% CI) AUC | - | - | - | - | - |