Literature DB >> 20841461

Comparison of digital systems and conventional dental film for the detection of approximal enamel caries.

A A Pontual1, D P de Melo, S M de Almeida, F N Bóscolo, F Haiter Neto.   

Abstract

OBJECTIVES: The aims of this study were (1) to compare the accuracy of the detection of approximal enamel caries lesions using three intraoral storage phosphor plate digital systems and one conventional film-based radiographic system; and (2) to determine whether there is a correlation between the histological and radiographic measurements of enamel caries.
METHODS: 160 approximal surfaces were radiographed under standardized conditions using three storage phosphor stimulable systems (DenOptix and Digora FMX with white and blue plates), and one film system (Insight film). 17 observers scored the images for the presence and depth of caries using a 4-point scale. The presence of caries was validated histologically (gold standard). Two-way analysis of variance was used to test the differences in sensitivity, specificity and overall accuracy (TP + TN). The data from the radiographic and histological measurements were statistically analysed by Spearman's rank correlation coefficient.
RESULTS: Two-way analysis of variance and the post hoc t-test demonstrated that Digora (white plate) had higher specificity and overall accuracy values than DenOptix (P = 0.021); there was no statistically significant difference among the other imaging modalities (P > 0.05). There was no significant correlation between the histological depth measurements and the radiographic measurements from Digora (blue plate) (P = 0.43), Digora (white plate) (P = 0.15), DenOptix (P = 0.17) and Insight film (P = 0.06).
CONCLUSIONS: The results suggest that (1) the performance of the three storage phosphor image plate systems was similar to that of the Insight film for detection of approximal enamel caries, and (2) the increase in histological depth of enamel caries was not significantly correlated with radiographic measurements.

Entities:  

Mesh:

Year:  2010        PMID: 20841461      PMCID: PMC3520190          DOI: 10.1259/dmfr/94985823

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  31 in total

1.  Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification: comparison with conventional radiography.

Authors:  D B Svanaes; A Møystad; S Risnes; T A Larheim; H G Gröndahl
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1996-07

2.  Progression of dental demineralization with and without modified tunnel restorations in vitro.

Authors:  P Eickholz; T Pioch; M Lenhard
Journal:  Oper Dent       Date:  1997 Sep-Oct       Impact factor: 2.440

3.  A comparison of Kodak Ektaspeed Plus film and the Siemens Sidexis digital imaging system for caries detection using receiver operating characteristic analysis.

Authors:  D A Tyndall; J B Ludlow; E Platin; M Nair
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-01

4.  Comparative performance of digital and conventional images for detecting proximal surface caries.

Authors:  S C White; D C Yoon
Journal:  Dentomaxillofac Radiol       Date:  1997-01       Impact factor: 2.419

5.  A method to monitor dental demineralisation in vitro.

Authors:  M Lenhard; T Mayer; T Pioch; P Eickholz
Journal:  Caries Res       Date:  1996       Impact factor: 4.056

6.  Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study.

Authors:  A Wenzel; E Borg; H Hintze; H G Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  1995-11       Impact factor: 2.419

7.  Radiographic detection of cavitation in approximal surfaces of primary teeth using a digital storage phosphor system and conventional film, and the relationship between cavitation and radiographic lesion depth: an in vitro study.

Authors:  L L Nielsen; M Hoernoe; A Wenzel
Journal:  Int J Paediatr Dent       Date:  1996-09       Impact factor: 3.455

8.  Validity and reproducibility of clinical examination, fibre-optic transillumination, and bite-wing radiology for the diagnosis of small approximal carious lesions: an in vitro study.

Authors:  A Peers; F J Hill; C M Mitropoulos; P J Holloway
Journal:  Caries Res       Date:  1993       Impact factor: 4.056

Review 9.  Dynamics of and diagnostic methods for detecting small carious lesions.

Authors:  C M Pine; J J ten Bosch
Journal:  Caries Res       Date:  1996       Impact factor: 4.056

10.  In vitro comparison of D- and E-speed film radiography, RVG, and visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions.

Authors:  H Hintze; A Wenzel; C Jones
Journal:  Caries Res       Date:  1994       Impact factor: 4.056

View more
  21 in total

1.  Diagnostic accuracy of proximal enamel subsurface demineralization and its relationship with calcium loss and lesion depth.

Authors:  E Onem; B G Baksi; B H Sen; O Sögüt; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

3.  Influence of brightness and contrast adjustments on the diagnosis of proximal caries lesions.

Authors:  Eduarda Hl Nascimento; Hugo Gaêta-Araujo; Karla F Vasconcelos; Bernardo B Freire; Christiano Oliveira-Santos; Francisco Haiter-Neto; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2018-06-15       Impact factor: 2.419

4.  Caries detection under composite restorations by laser fluorescence and digital radiography.

Authors:  Suwadee Kositbowornchai; Chotikpanich Sukanya; Tangkittikasem Tidarat; Thongsombat Chanoggarn
Journal:  Clin Oral Investig       Date:  2012-12-16       Impact factor: 3.573

5.  Radiographic diagnosis of proximal caries is not affected by exposure protocols and presence of high-density material on systems with automatic exposure compensation.

Authors:  Iris Rafaela Leão Gomes; Eduarda Helena Leandro Nascimento; Hugo Gaêta-Araujo; Maria Luiza Anjos Pontual; Flávia Maria Moraes Ramos-Perez; Andrea Dos Anjos Pontual
Journal:  Oral Radiol       Date:  2021-09-16       Impact factor: 1.882

6.  In Vitro Comparison of Diagnostic Accuracy of DIAGNOdent and Digital Radiography for Detection of Secondary Proximal Caries Adjacent to Composite Restorations.

Authors:  Zahra Ghoncheh; Zahra Zonouzy; Nazanin Kiomarsi; Mohammad Javad Kharazifar; Nasim Chiniforush
Journal:  J Lasers Med Sci       Date:  2017-09-27

7.  The prevalence of approximal caries in patients after fixed orthodontic treatment and in untreated subjects: a retrospective, cross-sectional study on bitewing radiographs.

Authors:  Stefan Baumgartner; Giorgio Menghini; Thomas Imfeld
Journal:  J Orofac Orthop       Date:  2013-01-11       Impact factor: 1.938

8.  Does the addition of a lead foil to digital radiographic receptors influence image contrast and approximal caries lesions diagnosis?

Authors:  Rocharles Cavalcante Fontenele; Yuri Nejaim; Amanda Farias Gomes; Hugo Gaêta-Araujo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2020-02-06       Impact factor: 2.419

9.  Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

Authors:  Maryam Tofangchiha; Mamak Adel; Mahin Bakhshi; Mahsa Esfehani; Pantea Nazeman; Mojgan Ghorbani Elizeyi; Amir Javadi
Journal:  Iran Endod J       Date:  2013-01-20

10.  Diagnostic accuracy of digital and conventional radiography in the detection of non-cavitated approximal dental caries.

Authors:  Farida Abesi; Alireza Mirshekar; Ehsan Moudi; Maryam Seyedmajidi; Sina Haghanifar; Nima Haghighat; Ali Bijani
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.