Literature DB >> 9195631

Comparison of a photostimulable phosphor system with film for dental radiology.

W Huda1, L N Rill, D K Benn, J C Pettigrew.   

Abstract

This study compared the imaging performance of a photostimulable phosphor system with E speed film for dental radiography. The response of each imaging system was measured as a function of radiation exposure. Measurements were also made of imaging performance in terms of the limiting spatial resolution and low contrast detectability. Photostimulable phosphors had a wider dynamic range in comparison with film. The limiting spatial resolution of the photostimulable phosphor was approximately 6.5 lp/mm and independent of image magnification. For film, the limiting spatial resolution was in the range 11 to 20 lp/mm depending on image magnification. At the same radiation exposure, low contrast detectability of the photostimulable phosphor was superior to that of film. Major benefits of photostimulable phosphor systems include the elimination of chemical processing and an improved low contrast detectability performance.

Mesh:

Year:  1997        PMID: 9195631     DOI: 10.1016/s1079-2104(97)90327-9

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  10 in total

1.  Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

Authors:  Elif Sogur; B Güniz Baksı; Kaan Orhan; S Candan Paksoy; Salih Dogan; Yılmaz S Erdal; Ali Mert
Journal:  Clin Oral Investig       Date:  2010-09-14       Impact factor: 3.573

2.  Ex vivo evaluation of new 2D and 3D dental radiographic technology for detecting caries.

Authors:  Laurence Gaalaas; Donald Tyndall; André Mol; Eric T Everett; Ananta Bangdiwala
Journal:  Dentomaxillofac Radiol       Date:  2015-12-16       Impact factor: 2.419

3.  Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment.

Authors:  Ligia Buloto Schmitd; Tatiana de Castro Lima; Luiz Eduardo Montenegro Chinellato; Clóvis Monteiro Bramante; Roberto Brandão Garcia; Ivaldo Gomes de Moraes; Norberti Bernardineli
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

4.  Measurement accuracy and perceived quality of imaging systems for the evaluation of periodontal structures.

Authors:  B Güniz Baksi
Journal:  Odontology       Date:  2008-07-27       Impact factor: 2.634

5.  Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation.

Authors:  Aswathy Kallaliel Vijayan; Shiana Jo; Benila Mathew; Mathew Vidyadharan; Aparna M Nair
Journal:  Contemp Clin Dent       Date:  2022-06-21

6.  In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX.

Authors:  Fernando Accorsi Orosco; Norberti Bernardineli; Roberto Brandão Garcia; Clovis Monteiro Bramante; Marco Antonio Húngaro Duarte; Ivaldo Gomes de Moraes
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

7.  Evaluation of the effects of processing delays and protective plastic cases on image quality of a photostimulable phosphor plate system.

Authors:  Clóvis Monteiro Bramante; Alexandre Silva Bramante; Rogério Emílio de Souza; Ivaldo Gomes Moraes; Norberti Bernardineli; Roberto Brandão Garcia
Journal:  J Appl Oral Sci       Date:  2008 Sep-Oct       Impact factor: 2.698

8.  Comparison of diagnostic methods for early interproximal caries detection with near-infrared light transillumination: an in vivo study.

Authors:  Ismail Hakki Baltacioglu; Kaan Orhan
Journal:  BMC Oral Health       Date:  2017-11-16       Impact factor: 2.757

9.  Diagnostic accuracy of digital and conventional radiography in the detection of non-cavitated approximal dental caries.

Authors:  Farida Abesi; Alireza Mirshekar; Ehsan Moudi; Maryam Seyedmajidi; Sina Haghanifar; Nima Haghighat; Ali Bijani
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

10.  Comparison of Diagnostic Ability of Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurement by Stereomicroscope: A Pilot Study.

Authors:  Velayudhannair Vivek; Sunila Thomas; Bindu J Nair; Alex Daniel Vineet; Jincy Thomas; Prasanna Ranimol; Aswathy K Vijayan
Journal:  Clin Pract       Date:  2015-09-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.