Literature DB >> 21698985

Detection of cavitated or non-cavitated approximal enamel caries lesions using CMOS and CCD digital X-ray sensors and conventional D and F-speed films at different exposure conditions.

Peter Bottenberg1, Wolfgang Jacquet, Vitus Stachniss, Johann Wellnitz, Andreas G Schulte.   

Abstract

PURPOSE: To determine the ability of digital sensors (CMOS and CCD sensors) and D and F-speed films to detect cavitated and non-cavitated enamel caries lesions at different exposure conditions compared to a gold standard.
METHODS: 100 extracted human molars and premolars were selected and mounted in a block between two neighboring teeth. Sensors or films were exposed with voltages of 60 or 70 kVp at varying times. Three observers assessed each approximal site independently. Lesion depth was rated according to an anatomical five-point scale (0 = no lesion to 4 = lesion reaching inner half of dentin). Serial sections of resin-embedded teeth were prepared. Gold-standard scores were established by consensus based on histological sectioning. A carious lesion was present at scores of 1 and higher. Statistical evaluation (sensitivity, specificity and receiver-operating curves) was based on caries-free surfaces and those presenting enamel caries (n=116).
RESULTS: The ROC curves had "area under the curve" values (Az) from 0.50 (F-speed, 70 kVp, 0.20 seconds) to 0.58 (CCD 60 kVp, 0.08 seconds). The detection percentage of cavitated lesions was generally higher (0-52%, depending on technique and observer) than that of non-cavitated lesions (3-32%). The CMOS sensor showed Az values comparable to the CCD sensors but required higher exposure times. There was no significant difference between 60 and 70 kVp.

Entities:  

Mesh:

Year:  2011        PMID: 21698985

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  9 in total

1.  Influence of brightness and contrast adjustments on the diagnosis of proximal caries lesions.

Authors:  Eduarda Hl Nascimento; Hugo Gaêta-Araujo; Karla F Vasconcelos; Bernardo B Freire; Christiano Oliveira-Santos; Francisco Haiter-Neto; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2018-06-15       Impact factor: 2.419

2.  The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries.

Authors:  Zahra Dalili Kajan; Reza Tayefeh Davalloo; Mayam Tavangar; Fatemeh Valizade
Journal:  Imaging Sci Dent       Date:  2015-06-19

3.  Does the addition of a lead foil to digital radiographic receptors influence image contrast and approximal caries lesions diagnosis?

Authors:  Rocharles Cavalcante Fontenele; Yuri Nejaim; Amanda Farias Gomes; Hugo Gaêta-Araujo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2020-02-06       Impact factor: 2.419

Review 4.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

5.  Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Liogi Iwaki Filho; Alfredo De Franco Queiroz; Lucas Bachegas Gomes Geron
Journal:  Contemp Clin Dent       Date:  2013-07

6.  Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography.

Authors:  Mohamed Khalifa Zayet; Yara Rabee Helaly; Salma Belal Eiid
Journal:  Imaging Sci Dent       Date:  2014-09-17

7.  Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries.

Authors:  Mahdieh Dehghani; Rasool Barzegari; Hosein Tabatabai; Sahar Ghanea
Journal:  J Dent (Tehran)       Date:  2017-01

8.  Diagnostic accuracy of digital and conventional radiography in the detection of non-cavitated approximal dental caries.

Authors:  Farida Abesi; Alireza Mirshekar; Ehsan Moudi; Maryam Seyedmajidi; Sina Haghanifar; Nima Haghighat; Ali Bijani
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

9.  Comparison of Diagnostic Ability of Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurement by Stereomicroscope: A Pilot Study.

Authors:  Velayudhannair Vivek; Sunila Thomas; Bindu J Nair; Alex Daniel Vineet; Jincy Thomas; Prasanna Ranimol; Aswathy K Vijayan
Journal:  Clin Pract       Date:  2015-09-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.