Literature DB >> 16041789

Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system.

Tsuyoshi Kitagawa1, Yasuhiro Tanimoto, Misako Odaki, Kimiya Nemoto, Masahiro Aida.   

Abstract

The objective of this study was to investigate the influence of implant/abutment joint designs on abutment screw loosening in a dental implant system, using nonlinear dynamic analysis of the finite element method (FEM). This finite element simulation study used two dental implant systems: the Ankylos implant system (Degusa Dental, Hanau, German) with a taper joint (taper joint-type model), and the Bränemark implant system (Nobel Biocare, Gothenburg, Sweden) with an external hex joint (external hex joint-type model). The nonlinear dynamic analysis was performed using three-dimensional finite element analysis. In comparing the movement of the taper type-joint model and external hex type-joint model, it was found that the external hex type-joint model had greater movement than the taper type-joint model. The external hex joint-type model showed rotation movement, whereas the movement of the taper joint-type model showed no rotation. It was concluded that the nonlinear dynamic analysis used in this study clearly demonstrated the differences in rotation of components in dental implant systems with taper or external hex joints. Copyright (c) 2005 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16041789     DOI: 10.1002/jbm.b.30328

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  16 in total

1.  FEM evaluation of cemented-retained versus screw-retained dental implant single-tooth crown prosthesis.

Authors:  Marco Cicciu; Ennio Bramanti; Giada Matacena; Eugenio Guglielmino; Giacomo Risitano
Journal:  Int J Clin Exp Med       Date:  2014-04-15

2.  Evaluation of implant screw loosening by resonance frequency analysis with triaxial piezoelectric pick-up: in vitro model and in vivo animal study.

Authors:  Makiko Miyashita; Toru Ogawa; Hideki Naito; Aya Shibamoto; Angelina Shuhua Wang; Kenta Shobara; Keiichi Sasaki
Journal:  Clin Oral Investig       Date:  2018-04-28       Impact factor: 3.573

3.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

4.  FEM and Von Mises analyses of different dental implant shapes for masticatory loading distribution.

Authors:  M Cicciù; E Bramanti; F Cecchetti; L Scappaticci; E Guglielmino; G Risitano
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

5.  Reliability and failure modes of narrow implant systems.

Authors:  Ronaldo Hirata; Estevam A Bonfante; Rodolfo B Anchieta; Lucas S Machado; Gileade Freitas; Vinicius P Fardin; Nick Tovar; Paulo G Coelho
Journal:  Clin Oral Investig       Date:  2015-11-03       Impact factor: 3.573

6.  Stress on external hexagon and Morse taper implants submitted to immediate loading.

Authors:  Caroline H Odo; Marcele J Pimentel; Rafael L X Consani; Marcelo F Mesquita; Mauro A A Nóbilo
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-29

7.  Nonlinear finite element analysis of three implant- abutment interface designs.

Authors:  Chun-Bo Tang; Si-Yu Liul; Guo-Xing Zhou; Jin-Hua Yu; Guang-Dong Zhang; Yi-Dong Bao; Qiu-Ju Wang
Journal:  Int J Oral Sci       Date:  2012-06       Impact factor: 6.344

Review 8.  Morse taper dental implants and platform switching: The new paradigm in oral implantology.

Authors:  José Paulo Macedo; Jorge Pereira; Brendan R Vahey; Bruno Henriques; Cesar A M Benfatti; Ricardo S Magini; José López-López; Júlio C M Souza
Journal:  Eur J Dent       Date:  2016 Jan-Mar

9.  Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Authors:  Takashi Matsuoka; Tamaki Nakano; Satoshi Yamaguchi; Shinji Ono; Shota Watanabe; Takumi Sato; Hirofumi Yatani
Journal:  Materials (Basel)       Date:  2021-05-06       Impact factor: 3.623

10.  FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods.

Authors:  M Cicciù; G Cervino; E Bramanti; F Lauritano; G Lo Gudice; L Scappaticci; A Rapparini; E Guglielmino; G Risitano
Journal:  Comput Math Methods Med       Date:  2015-12-21       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.