Literature DB >> 10371920

Strategies to achieve fit in implant prosthodontics: a review of the literature.

A G Wee1, S A Aquilino, R L Schneider.   

Abstract

PURPOSE: This paper reviews the literature on advanced strategies that attempt to improve fit in implant prosthodontics with reference to the concept of the "distortion equation."
MATERIALS AND METHODS: The majority of the articles reviewed were either clinical or technique articles that advocated strategies to improve fit in implant prosthodontics. A limited number of retrospective and prospective clinical trial studies were included as they related to the topic. Reviewed articles were limited to those that addressed advanced strategies to improve fit. All of the scientific studies included in this review used an in vitro experimental design. The advanced strategies were categorized into methods that address intraoral indexing and methods that use the implant master cast.
RESULTS: Relatively few methods have been scientifically proven to improve fit in implant prosthodontics. Most of the tested strategies still resulted in a slight misfit of the frameworks to the implant abutments/analogues.
CONCLUSION: Multiple factors preclude that the concept of "passive fit" can be achieved in implant prosthodontics, even with the use of advanced strategies. The use of meticulous, accurate implant prosthodontic procedures and the appropriate use of advanced strategies continue to be the recommended means of achieving precise fit of the implant prosthesis to the intraoral abutments.

Mesh:

Year:  1999        PMID: 10371920

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  18 in total

1.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

2.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

Review 3.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

4.  Stress on external hexagon and Morse taper implants submitted to immediate loading.

Authors:  Caroline H Odo; Marcele J Pimentel; Rafael L X Consani; Marcelo F Mesquita; Mauro A A Nóbilo
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-29

5.  Experimental study on the factors affecting torque of beam-type implant torque wrenches.

Authors:  Hiroki Shiba; Yuji Sato; Junichi Furuya; Tokiko Osawa; Akio Isobe; Myu Hayashi; Noboru Kitagawa
Journal:  BMC Oral Health       Date:  2021-07-15       Impact factor: 2.757

6.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

7.  Impression of multiple implants using photogrammetry: description of technique and case presentation.

Authors:  David Peñarrocha-Oltra; Rubén Agustín-Panadero; Leticia Bagán; Beatriz Giménez; María Peñarrocha
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-07-01

8.  The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding.

Authors:  Daniela Castilio; Ana Paula Ribeiro do Vale Pedreira; Paulo Henrique Orlato Rossetti; Leylha Maria Nunes Rossetti; Wellington Cardoso Bonachela
Journal:  J Appl Oral Sci       Date:  2006-04       Impact factor: 2.698

9.  Wear, microleakage and plastic deformation of an implant-supported chair-side bar system.

Authors:  Christian Johannes Mehl; Martin Steiner; Klaus Ludwig; Matthias Kern
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

10.  Dimensional stability of two solder index materials.

Authors:  Amir Ali Reza Khaledi; Soheil Pardis; Negar Pourhatami; Zahra Hashemi Ardakani
Journal:  Eur J Dent       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.