Literature DB >> 26587550

Quantitative performance characterization of image quality and radiation dose for a CS 9300 dental cone beam computed tomography machine.

Elham Abouei1, Sierra Lee2, Nancy L Ford3.   

Abstract

This paper aims to characterize the radiation dose and image quality (IQ) performance of a dental cone beam computed tomography (CBCT) unit over a range of fields of view (FOV). IQ and dose were measured using a Carestream 9300 dental CBCT. Phantoms were positioned in the FOV to imitate clinical positioning. IQ was assessed by scanning a SEDENTEXCT IQ phantom, and images were analyzed in ImageJ. Dose index 1 was obtained using a thimble ionization chamber and SEDENTEXCT DI phantom. Mean gray values agreed within 93.5% to 99.7% across the images, with pixel-to-pixel fluctuations of 6% to 12.5%, with poorer uniformity and increased noise for child protocols. CNR was fairly constant across FOVs, with higher CNR for larger patient settings. The measured limiting spatial resolution agreed well with 10% MTF and bar pattern measurements. Dose was reduced for smaller patient settings within a given FOV; however, smaller FOVs obtained with different acquisition settings did not necessarily result in reduced dose. The use of patient-specific acquisition settings decreased the radiation dose for smaller patients, with minimal impact on the IQ. The full set of IQ and dose measurements is reported to allow dental professionals to compare the different FOV settings for clinical use.

Entities:  

Keywords:  computer tomography; image evaluation; image quality; imaging

Year:  2015        PMID: 26587550      PMCID: PMC4650966          DOI: 10.1117/1.JMI.2.4.044002

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  23 in total

1.  Quantification of metal artifacts on cone beam computed tomography images.

Authors:  Ruben Pauwels; Harry Stamatakis; Hilde Bosmans; Ria Bogaerts; Reinhilde Jacobs; Keith Horner; Kostas Tsiklakis
Journal:  Clin Oral Implants Res       Date:  2011-12-15       Impact factor: 5.977

2.  Accuracy in measurement of distance using limited cone-beam computerized tomography.

Authors:  Kaoru Kobayashi; Shinji Shimoda; Yoichi Nakagawa; Akira Yamamoto
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Mar-Apr       Impact factor: 2.804

3.  A quality assurance phantom for the performance evaluation of volumetric micro-CT systems.

Authors:  Louise Y Du; Joseph Umoh; Hristo N Nikolov; Steven I Pollmann; Ting-Yim Lee; David W Holdsworth
Journal:  Phys Med Biol       Date:  2007-11-15       Impact factor: 3.609

4.  The 'Image Gently' campaign: increasing CT radiation dose awareness through a national education and awareness program.

Authors:  Marilyn J Goske; Kimberly E Applegate; Jennifer Boylan; Penny F Butler; Michael J Callahan; Brian D Coley; Shawn Farley; Donald P Frush; Marta Hernanz-Schulman; Diego Jaramillo; Neil D Johnson; Sue C Kaste; Gregory Morrison; Keith J Strauss; Nora Tuggle
Journal:  Pediatr Radiol       Date:  2008-01-17

5.  Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system.

Authors:  J A Bryant; N A Drage; S Richmond
Journal:  Dentomaxillofac Radiol       Date:  2008-10       Impact factor: 2.419

6.  Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners.

Authors:  A Suomalainen; T Kiljunen; Y Käser; J Peltola; M Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2009-09       Impact factor: 2.419

7.  A phantom for simplified image quality control of dental cone beam computed tomography units.

Authors:  Gerald R Torgersen; Caroline Hol; Anne Møystad; Kristina Hellén-Halme; Mats Nilsson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2014-08-15

8.  A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography.

Authors:  Christian Steiding; Daniel Kolditz; Willi A Kalender
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

9.  Measuring absorbed dose for i-CAT CBCT examinations in child, adolescent and adult phantoms.

Authors:  E Choi; N L Ford
Journal:  Dentomaxillofac Radiol       Date:  2015-03-18       Impact factor: 2.419

10.  Development and applicability of a quality control phantom for dental cone-beam CT.

Authors:  Ruben Pauwels; Harry Stamatakis; Giorgos Manousaridis; Adrian Walker; Koen Michielsen; Hilde Bosmans; Ria Bogaerts; Reinhilde Jacobs; Keith Horner; Kostas Tsiklakis
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

View more
  6 in total

1.  Bayesian framework inspired no-reference region-of-interest quality measure for brain MRI images.

Authors:  Michael Osadebey; Marius Pedersen; Douglas Arnold; Katrina Wendel-Mitoraj
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-13

Review 2.  Quality assurance phantoms for cone beam computed tomography: a systematic literature review.

Authors:  Marcus V L de Oliveira; Ann Wenzel; Paulo S F Campos; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

3.  Image registration assessment in radiotherapy image guidance based on control chart monitoring.

Authors:  Wenyao Xia; Stephen L Breen
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-14

4.  Relationship between CNR and visibility of anatomical structures of cone-beam computed tomography images under different exposure parameters.

Authors:  Miss Fei Wang; Xiaoyan Xie; Gang Li; Zuyan Zhang
Journal:  Dentomaxillofac Radiol       Date:  2020-02-26       Impact factor: 2.419

5.  Midfacial soft tissue changes after maxillary expansion using micro-implant-supported maxillary skeletal expanders in young adults: A retrospective study.

Authors:  Hieu Nguyen; Jeong Won Shin; Hai-Van Giap; Ki Beom Kim; Hwa Sung Chae; Young Ho Kim; Hae Won Choi
Journal:  Korean J Orthod       Date:  2021-05-25       Impact factor: 1.372

6.  Comparison of the CTDI and AAPM report No. 111 methodology in adult, adolescent, and child head phantoms for MSCT and dental CBCT scanners.

Authors:  Celina L Li; Yogesh Thakur; Nancy L Ford
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.