Literature DB >> 15101594

Accuracy in measurement of distance using limited cone-beam computerized tomography.

Kaoru Kobayashi1, Shinji Shimoda, Yoichi Nakagawa, Akira Yamamoto.   

Abstract

PURPOSE: The purpose of this study was to evaluate the accuracy of measurement of distance on the images produced by limited cone-beam computerized tomography (CT).
MATERIALS AND METHODS: Five cadaver mandibles were examined by spiral computerized tomography (SCT) and limited cone-beam computerized tomography (LCBCT). The vertical distance from a reference point to the alveolar ridge was measured by caliper on the sliced mandible, and measurement error on the CT images was calculated in percentages based on the actual values and the measurement values obtained from the CT images.
RESULTS: Measurement error was determined to range from 0 to 1.11 mm (0% to 6.9%) on SCT and from 0.01 to 0.65 mm (0.1% to 5.2%) on LCBCT, with measurement errors of 2.2% and 1.4%, respectively (P < .0001). DISCUSSION: This study suggests that distance can be measured accurately using LCBCT. The size of the rectangular solid images obtained using LCBCT (30 mm wide and 42.7 mm long) is thought to be adequate for observation of mandibular bony structure and for preoperative assessment before dental implant placement.
CONCLUSION: In this experiment on cadaver mandibles, LCBCT was shown to be a useful tool for preoperative evaluation in dental surgery because the relatively small field size of its images limits the patient's exposure to radiation.

Entities:  

Mesh:

Year:  2004        PMID: 15101594

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  85 in total

1.  Effect of electric potential and current on mandibular linear measurements in cone beam CT.

Authors:  S Panmekiate; W Apinhasmit; A Petersson
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  A comparative study of accuracy of detection of surface osseous changes in the temporomandibular joint using multidetector CT and cone beam CT.

Authors:  E H Zain-Alabdeen; R I Alsadhan
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

3.  Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning.

Authors:  Paul W Poeschl; Nina Schmidt; Godoberto Guevara-Rojas; Rudolf Seemann; Rolf Ewers; Harald T Zipko; Kurt Schicho
Journal:  Clin Oral Investig       Date:  2012-03-14       Impact factor: 3.573

4.  A suggested technique for the application of the cone beam computed tomography periapical index.

Authors:  S Esposito; M Cardaropoli; E Cotti
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

5.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

6.  Evaluation of the accuracy of linear measurements on spiral computed tomography-derived three-dimensional images and its comparison with digital cephalometric radiography.

Authors:  S Varghese; V Kailasam; S Padmanabhan; B Vikraman; A Chithranjan
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

7.  Oral Implant Imaging: A Review.

Authors:  Sarika Gupta; Neelkant Patil; Jitender Solanki; Ravinder Singh; Sanjeev Laller
Journal:  Malays J Med Sci       Date:  2015 May-Jun

8.  Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography.

Authors:  Carlos Eduardo Gomes do Couto-Filho; Paulo Hemerson de Moraes; Maria Beatriz Carrazzone Alonso; Francisco Haiter-Neto; Sergio Olate; José Ricardo de Albergaria-Barbosa
Journal:  Int J Morphol       Date:  2015-03       Impact factor: 0.519

9.  A Comparison of the Change in Mandibular Condyle/Fossa Relationship with the Use of Anatomic Teeth and Semi-anatomic Teeth in Complete Denture Prosthesis.

Authors:  Satyabodh S Guttal; Ramesh K Nadiger; Abhishek Suvarna
Journal:  J Indian Prosthodont Soc       Date:  2013-02-22

10.  CBCT-based bone quality assessment in decompression of large odontogenic cystic lesions.

Authors:  Ling Gao; Wenhao Ren; Shaoming Li; Jingjing Zheng; Lingfa Xue; Yaoxiang Xu; Qibo Wang; Jianzhong Song; Zhichao Dou; Minzhan Zhou; Wenlin Xiao; Keqian Zhi
Journal:  Oral Radiol       Date:  2018-02-14       Impact factor: 1.852

View more