A quality assurance phantom for the performance evaluation of volumetric micro-CT systems.

Louise Y Du1, Joseph Umoh, Hristo N Nikolov, Steven I Pollmann, Ting-Yim Lee, David W Holdsworth.   

Abstract

Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 microm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm(-1) and noise of +/-35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.

Entities:  

Mesh:

Year:  2007        PMID: 18029995     DOI: 10.1088/0031-9155/52/23/021

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  35 in total

1.  Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response.

Authors:  Fabian Eisa; Robert Brauweiler; Martin Hupfer; Tristan Nowak; Laura Lotz; Inge Hoffmann; David Wachter; Ralf Dittrich; Matthias W Beckmann; Gregor Jost; Hubertus Pietsch; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-11-10       Impact factor: 5.315

2.  On the computational implementation of forward and back-projection operations for cone-beam computed tomography.

Authors:  Davood Karimi; Rabab Ward
Journal:  Med Biol Eng Comput       Date:  2015-10-05       Impact factor: 2.602

3.  How do CAD models compare with reverse engineered manufactured components for use in wear analysis?

Authors:  Matthew G Teeter; Douglas D R Naudie; Robert B Bourne; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

4.  Characterization of image quality and image-guidance performance of a preclinical microirradiator.

Authors:  R Clarkson; P E Lindsay; S Ansell; G Wilson; S Jelveh; R P Hill; D A Jaffray
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

5.  The effect of different image reconstruction techniques on pre-clinical quantitative imaging and dual-energy CT.

Authors:  Ana Vaniqui; Lotte E J R Schyns; Isabel P Almeida; Brent van der Heyden; Mark Podesta; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-11-07       Impact factor: 3.039

6.  MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging.

Authors:  Jean-Philippe Dillenseger; Jean-François Matern; Catherine-Isabelle Gros; Fabien Bornert; Christian Goetz; Jean-Marie Le Minor; André Constantinesco; Philippe Choquet
Journal:  Eur Radiol       Date:  2014-09-24       Impact factor: 5.315

7.  Image quality evaluation of small FOV and large FOV CBCT devices for oral and maxillofacial radiology.

Authors:  Jean-Philippe Dillenseger; Catherine-Isabelle Gros; Amira Sayeh; Johary Rasamimanana; Fabrice Lawniczak; Jean-Marie Leminor; Jean-François Matern; André Constantinesco; Fabien Bornert; Philippe Choquet
Journal:  Dentomaxillofac Radiol       Date:  2016-09-21       Impact factor: 2.419

8.  Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results.

Authors:  Brian E Nett; Robert Brauweiler; Willi Kalender; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2010-04-01       Impact factor: 3.609

9.  Positive Effects of Qing'e Pill () on Trabecular Microarchitecture and its Mechanical Properties in Osteopenic Ovariectomised Mice.

Authors:  Bo Shuai; Rui Zhu; Yan-Ping Yang; Lin Shen; Xiao-Juan Xu; Chen Ma; Lin Lu
Journal:  Chin J Integr Med       Date:  2016-10-24       Impact factor: 1.978

10.  Cone beam micro-CT system for small animal imaging and performance evaluation.

Authors:  Shouping Zhu; Jie Tian; Guorui Yan; Chenghu Qin; Jinchao Feng
Journal:  Int J Biomed Imaging       Date:  2009-09-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.